Dong Wook Kim

Dong Wook Kim

Auto-generated profile, based on publicly available information

Dong Wook Kim

Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, South Korea

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
WMWon-Jin Moon
Won-Jin Moon
JBJung Hwan Baek
Jung Hwan Baek
SJSo Lyung Jung
So Lyung Jung
DKDong Wook Kim
Dong Wook Kim
EKEun Kyung Kim
Eun Kyung Kim
KRKorean Society Of Radiology
Korean Society Of Radiology
Moon WJ, et al. Korean J Radiol. 2011 Jan-Feb;12(1):1-14. http://dx.doi.org/10.3348/kjr.2011.12.1.1

1 January 2012 in Radiology
Verified
Journal Article
Closed access
JBJung Hwan Baek
Jung Hwan Baek
JLJeong Hyun Lee
Jeong Hyun Lee
JSJin Yong Sung
Jin Yong Sung
JBJae-Ik Bae
Jae-Ik Bae
KKKyung Tae Kim
Kyung Tae Kim
FRFor The Korean Society Of Thyroid Radiology
For The Korean Society Of Thyroid Radiology
To evaluate clinical aspects and imaging features of complications encountered in the treatment of benign thyroid nodules with radiofrequency (RF) ablation. Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From June 2002 to September 2009, 1459 patients underwent RF ablation of 1543 thyroid nodules with an RF system with internally cooled electrodes at 13 thyroid centers, which were members of Korean Society of Thyroid Radiology. Numbers and types of major and minor complications were assessed. The authors observed 48 complications (3.3%), 20 major and 28 minor. The major complications were voice changes (n = 15), brachial plexus injury (n = 1), tumor rupture (n = 3), and permanent hypothyroidism (n = 1). The minor complications were hematoma (n = 15), skin burn (n = 4), and vomiting (n = 9). All patients recovered spontaneously except for one with permanent hypothyroidism and one who underwent surgery. Although the complication rate of RF ablation is low, various complications may occur; comprehension of complications and suggested technical tips may prevent complications or properly manage those that occur.

1 January 2012 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
DNDong Gyu Na
Dong Gyu Na
JLJeong Hyun Lee
Jeong Hyun Lee
SJSo Lyung Jung
So Lyung Jung
JKJi-hoon Kim
Ji-hoon Kim
JSJin Yong Sung
Jin Yong Sung
KRKorean Society Of Radiology
Korean Society Of Radiology
Na DG, et al. Korean J Radiol. 2012 Mar-Apr;13(2):117-125. http://dx.doi.org/10.3348/kjr.2012.13.2.117

1 January 2009 in Thyroid®
Verified
Journal Article
Closed access
DKDong Wook Kim
Dong Wook Kim
ELEun Joo Lee
Eun Joo Lee
SKSang Hyo Kim
Sang Hyo Kim
TKTae Hyun Kim
Tae Hyun Kim
SLSang Hyub Lee
Sang Hyub Lee
MRMyung Ho Rho
Myung Ho Rho
Background: The objective of this study was to compare the efficacy and procedure time of ultrasound-guided fine-needle aspiration biopsy (US-FNAB) of thyroid nodules, according to the nodule size. Methods: US-FNABs of thyroid nodules performed between June 2007 and December 2007 were studied. We divided these patients into three groups according to the largest diameter of their nodules. Group A consisted of patients with thyroid nodules less than or equal to 5 mm, group B of patients with thyroid nodules greater than 5 mm and less than or equal to 10 mm, and group C of patients with thyroid nodules greater than 10 mm. We retrospectively reviewed the cytopathology results and complications in all three patient groups and measured the separate, total US-FNAB procedure time for each of 20 randomly selected thyroid nodules. Results: US-FNAB was performed on 438 thyroid nodules in 253 patients. In groups A, B, and C, the adequacy rates from the first US-FNAB were 79.6% (90/113), 90.6% (125/138), and 95.2% (178/187), respectively. In groups A, B, and C, 113, 138, and 187 thyroid nodules in 100, 120, and 169 patients, respectively, revealed 59, 75, and 126 benign; 12, 11, and 9 suspicious for malignancy; 9, 32, and 29 malignant; 10, 7, and 14 inderminate for malignancy; and 23, 13, and 9 inadequate on the first US-FNAB. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were determined to be 85.7%, 100%, 100%, 94.9%, and 96.1% in group A; 97.7%, 100%, 100%, 98.7%, and 99.1% in group B; and 100%, 99.2%, 97.1%, 100%, and 99.4% in group C. The mean procedure times in groups A, B, and C were 2 minutes 33 seconds, 1 minute 50 seconds, and 1 minute 32 seconds, respectively. There were no significant patient complications in any of the three patient groups. Conclusions: US-FNAB of thyroid nodules smaller than 5 mm in maximum diameter was less successful, and the sensitivity was lower than those of nodules larger than 5 mm. We considered, however, that the sampling adequacy and efficacy of US-FNAB of thyroid nodules less than 5 mm in maximum diameter was satisfactory in our series and should be similar in other centers with similar characteristics to ours.

1 January 2011 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
YLYoung Hun Lee
Young Hun Lee
DKDong Wook Kim
Dong Wook Kim
HIHyun Sin In
Hyun Sin In
JPJi Sung Park
Ji Sung Park
SKSang Hyo Kim
Sang Hyo Kim
MRMyung Ho Rho
Myung Ho Rho
Lee YH, et al. Korean J Radiol. 2011 Sep-Oct;12(5):559-567. http://dx.doi.org/10.3348/kjr.2011.12.5.559

1 August 2001 in The Laryngoscope
Verified
Journal Article
Closed access
PDF file
MSMyung‐Whun Sung
Myung‐Whun Sung
DLDong‐Wook Lee
Dong‐Wook Lee
DKDong‐Young Kim
Dong‐Young Kim
SLSang‐Jun Lee
Sang‐Jun Lee
CHChan Ho Hwang
Chan Ho Hwang
KKKwang Hyun Kim
Kwang Hyun Kim