Myron C. Gerson

Myron C. Gerson

Auto-generated profile, based on publicly available information

Myron C. Gerson

University of Cincinnati College of Medicine

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2002 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
MGMyron C. Gerson
Myron C. Gerson
LCLaura L. Craft
Laura L. Craft
NMNancy McGuire
Nancy McGuire
DSDamodhar P. Suresh
Damodhar P. Suresh
WAWilliam T. Abraham
William T. Abraham
LWLynne E. Wagoner
Lynne E. Wagoner

1 March 2011 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MGMyron C. Gerson
Myron C. Gerson
JCJames H. Caldwell
James H. Caldwell
KAKarthik Ananthasubramaniam
Karthik Ananthasubramaniam
ICIan P. Clements
Ian P. Clements
MHMilena J. Henzlova
Milena J. Henzlova
AJArnold F. Jacobson
Arnold F. Jacobson
Background— Patients with diabetes mellitus have accelerated progression of heart failure and often have impaired cardiac sympathetic innervation. The present study examines the implications for heart failure progression of cardiac sympathetic denervation, assessed by I-123 metaiodobenzylguanidine imaging, in diabetic compared with nondiabetic subjects. Methods and Results— We evaluated 343 diabetic and 618 nondiabetic subjects with New York Heart Association class II or III heart failure and a left ventricular ejection fraction ≤35% over a median follow-up of 17 months. A multivariable Cox proportional hazards model was used to examine the influence of clinical variables, b-type natriuretic peptide, plasma norepinephrine, left ventricular ejection fraction, and I-123 metaiodobenzylguanidine imaging parameters on time to a heart failure event. The late heart-to-mediastinum (H/M) ratio and the interaction term of diabetes mellitus with the prospectively selected late H/M ratio <1.6 were independent predictors of heart failure progression, providing incremental prognostic information beyond that available from all other variables. In diabetic subjects, late H/M ratio <1.6 was associated with a 2.99-fold greater 2-year rate of heart failure progression (33.5%) than late H/M ratio ≥1.6 (11.2% event rate). Conclusions— The combination of diabetes mellitus and I-123 metaiodobenzylguanidine H/M ratio is an independent predictor of heart failure progression, confirming the high risk of diabetic subjects with impaired cardiac sympathetic nerve function. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00126438 and NCT00126425.

1 January 2002 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
MSMathew Shotwell
Mathew Shotwell
BSBalkrishna M. Singh
Balkrishna M. Singh
CFCharlotte Fortman
Charlotte Fortman
BBBrian D. Bauman
Brian D. Bauman
JLJennifer Lukes
Jennifer Lukes
MGMyron C. Gerson
Myron C. Gerson

14 November 2016 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
HJHina K. Jamali
Hina K. Jamali
FWFahad Waqar
Fahad Waqar
MGMyron C. Gerson
Myron C. Gerson

16 February 2020 in Topics in Stroke Rehabilitation
Verified
Journal Article
Open access
PBPierce Boyne
Pierce Boyne
VSVictoria Scholl
Victoria Scholl
SDSarah Doren
Sarah Doren
DCDaniel Carl
Daniel Carl
SBSandra A. Billinger
Sandra A. Billinger
KDKari Dunning
Kari Dunning
Background and Objectives: High-intensity interval training (HIIT) is a promising strategy for improving gait and fitness after stroke, but optimal parameters remain unknown. We tested the effects of short vs long interval type and over-ground vs treadmill mode on training intensity. Methods: Using a repeated measures design, 10 participants with chronic hemiparesis performed 12 HIIT sessions over 4 weeks, alternating between short and long-interval HIIT sessions. Both protocols included 10 minutes of over-ground HIIT, 20 minutes of treadmill HIIT and another 10 minutes over-ground. Short-interval HIIT involved 30 second bursts at maximum safe speed and 30–60 second rest periods. Long-interval HIIT involved 4-minute bursts at ~90% of peak heart rate (HRpeak) and 3-minute recovery periods at ~70% HRpeak. Results: Compared with long-interval HIIT, short-interval HIIT had significantly faster mean overground speeds (0.75 vs 0.67 m/s) and treadmill speeds (0.90 vs 0.51 m/s), with similar mean treadmill HR (82.9 vs 81.8%HRpeak) and session perceived exertion (16.3 vs 16.3), but lower overground HR (78.4 vs 81.1%HRpeak) and session step counts (1481 vs 1672). For short-interval HIIT, training speeds and HR were significantly higher on the treadmill vs. overground. For long-interval HIIT, the treadmill elicited HR similar to overground training at significantly slower speeds. Conclusions: Both short and long-interval HIIT elicit high intensities but emphasize different dosing parameters. From these preliminary findings and previous studies, we hypothesize that overground and treadmill short-interval HIIT could be optimal for improving gait speed and overground long-interval HIIT could be optimal for improving gait endurance.

1 March 2017 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Open access
DCDaniel L. Carl
Daniel L. Carl
PBPierce Boyne
Pierce Boyne
BRBradley Rockwell
Bradley Rockwell
MGMyron Gerson
Myron Gerson
JKJane C. Khoury
Jane C. Khoury
KDKari Dunning
Kari Dunning
The purpose of this study was to assess safety via electrocardiographic (ECG), blood pressure (BP), heart rate (HR), and orthopedic responses to 3 different high-intensity interval training (HIIT) protocols in persons with stroke. Eighteen participants (10 male; 61.9 + 8.3 years of age; 5.8 + 4.2 years poststroke) completed a symptom-limited graded exercise test (GXT) with ECG monitoring to screen for eligibility and determine HR peak. The 3 HIIT protocols involved repeated 30 s bursts of treadmill walking at maximum speed alternated with rest periods of 30 s (P30), 1 min (P60), or 2 min (P120). Sessions were performed in random order and included 5 min warm up, 20 min HIIT, and 5 min cool down. Variables measured included ECG activity, BP, HR, signs and symptoms of cardiovascular intolerance, and orthopedic concerns. Generalized linear mixed models and Tukey–Kramer adjustment were used to compare protocols using p < 0.05. No signs or symptoms of cardiovascular intolerance, significant arrhythmias, ST segment changes, or orthopedic responses resulted in early termination of any HIIT session. HIIT elicited HRs in excess of 88% of measured HRpeak including 6 (P30), 8 (P60), and 2 (P120) participants eliciting a HR response above their GXT HRpeak. Both maximum BP and HR were significantly higher in P30 and P60 relative to P120. Preliminary data indicate that persons with chronic stroke who have been prescreened with an ECG stress test, a symptom-limited GXT, and a harness for fall protection may safely participate in HIIT, generating substantially higher HRs than what is seen in traditional moderate intensity training.