In order to measure the shape of fast convex aspherics, such as the corneal surface of the human eye, we propose the design of a conical null-screen with a radial point distribution (spots similar to ellipses) drawn on it in such a way that its image, which is formed by reflection on the test surface, becomes an exact array of circular spots if the surface is perfect. Any departure from this geometry is indicative of defects on the evaluated surface. We present the target array design and the surface evaluation algorithm. The precision of the test is increased by performing an iterative process to calculate the surface normals, reducing the numerical errors during the integration. We show the applicability of the null-screen based topographer by testing a spherical calibration surface of 7.8 mm radius of curvature and 11 mm in diameter. Here we obtain an rms difference in sagitta between the evaluated surface and the best-fitting sphere less than 1 μm.
We propose a method for measuring the shape of freeform surfaces such as Progressive Addition Lenses (PAL). It is based on optical deflectometry by considering a non-uniform pattern of spots computed by using the null-screen method. This pattern is displayed on a flat LCD monitor being reflected on the freeform under test and whose image is recorded on a CCD camera placed at a predefined off-axis position. We use one image to calibrate the experimental setup and another to measure the freeform surface. We develop an iterative algorithm to retrieve the surface under test and calculate the spherical and cylindrical dioptric powers of the frontal freeform of a commercial PAL under test.
In this work, we present a technique for quantitatively assessing the optical quality of a parabolic trough solar collector. The presented method is an adaptation of the null-screen technology, a collection of processes that retrieve information from the reflection of a known object from the surface and then use that information to reconstruct the surface’s normal vectors. Via numerical simulations, it is shown that the precision attainable by this method is up to 0.068 mrad, depending on the source of systematical error. In this study we only consider displacements of the physical null-screen as sources of error.
To measure the shape of the fast corneal surface of the human eye, we propose the design and characterization of a compact corneal topographer using the capabilities of a smartphone. The performance evaluation of the compact corneal topographer includes the calculation and compensation of the distortion introduced by the smartphone lens used to acquire the images and the evaluation of a reference surface. To demonstrate the feasibility of our proposal, we performed surface topography measurements on some human corneas and compared the results with those obtained by a commercial corneal topographer. We showed that the results obtained with our algorithms were consistent with other methods that analyze the corneal surface.
A method for the evaluation of the shape of fast conical surfaces based on the null-screen method is presented. The proposed method is based on randomized algorithms, where instead of integration as is usually performed, the shape of the surface is recovered in a direct and random way. This is done by proposing a new test surface; the surface parameters are randomly generated and the calculated null-screen is compared against the originally designed one. The coefficients that generate the null-screen closest to the reference null-screen are taken as the final values that describe the surface under test. The algorithm validation was done in the theoretical and experimental way. For the theoretical way, a convex parabolic surface with 21.36 mm radius of curvature and f/0.178 was simulated and analyzed; in the experimental way, a convex spherical surface f/0.33 and a concave ellipsoidal mirror f/0.2381 were evaluated. The results obtained with our algorithm in the evaluation of the ellipsoidal surface were compared against the results obtained with traditional methods. We found that the radius of curvature, conic constant, and the decentering coefficients that were used to generate each surface were retrieved in a good manner with our algorithm. The results show that these parameters can be recovered with a percent error smaller than 1% in the case of simulations, and smaller than 2% in the two experimental cases.
Misalignments are a common problem in corneal topography reconstruction. To determine the topography of the surface using a corneal topographer based on the null-screen method, it is necessary to measure errors caused by mechanical misalignment of the topographer, which could influence the results of this technique but are not related to the quality of the corneal surface. To evaluate the variability in measurements, in this work, we simulate some misalignments in the optical system, for the simulation we design a semi-radial null-screen to test a reference spherical surface to identify the variations in results introduced by misalignment errors of the corneal topographer with respect to the test surface. According to the simulations, the accuracy of the null-screen method ranges from 0.81 µm to 2.84 µm for typical tilt, decentering, and defocusing errors. Experimental results for the testing of a spherical surface are shown. After removing the misalignments, we found that the variations are approximately 3.5 μm rms value measured with respect to the best-fitting sphere, and the radius of curvature differs approximately 0.06% from the design value.