Phani Kumar Chamarthi

Phani Kumar Chamarthi

Auto-generated profile, based on publicly available information

Phani Kumar Chamarthi

Holcombe Department of Electrical and Computer Engineering, Clemson University, Clemson, SC, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in IEEE Access
Verified
Journal Article
Open access
SRS. M. Imrat Rahman
S. M. Imrat Rahman
Ali MoghassemiAli Moghassemi
Ali Moghassemi
AAAli Arsalan
Ali Arsalan
LTLaxman Timilsina
Laxman Timilsina
PCPhani Kumar Chamarthi
Phani Kumar Chamarthi
CEChris S. Edrington
Chris S. Edrington
Recently, the thermal management of power electronic converters has gained significant attention due to the continuous trend of developing very compact power electronic converters with high power density. With the evolution of power semiconductor devices, high operating temperatures and large thermal cycles have become possible, necessitating a significant improvement in thermal system designs. Researchers have made significant efforts to develop effective thermal management systems to improve the reliability and lifetime of power electronic converters. This article intends to present a thorough review of thermal management systems employed in power electronics cooling. The applied thermal management techniques have been reviewed from the perspective of electrical parameter regulation and heat dissipation control. Regulation of electrical parameters involves active thermal control, which is a method for controlling junction temperature and thermal cycling of power semiconductor devices. The active thermal control implementation processes reviewed in this article consist of increasing overload capacity, manipulating switching and conduction losses, employing modified modulation processes, balancing thermal stress at the converter level, and controlling thermal stress at the system level. Control of heat dissipation can be achieved through direct and indirect cooling of power electronic converters with air or liquid as the coolant. The effectiveness and implementation methods of these cooling techniques, such as channel cooling, phase change material-based cooling, immersion cooling, jet impingement and spray cooling, are reviewed in this paper. Moreover, performance-enhancing ideas and challenges for these techniques are discussed. The primary objective of this review paper is to bridge the existing gap in the literature by offering a comprehensive comparison of commonly employed thermal management techniques.

4 February 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
PCPhani Kumar Chamarthi
Phani Kumar Chamarthi
Ahmed Al-DurraAhmed Al-Durra
Ahmed Al-Durra
TETarek H. M. El-Fouly
Tarek H. M. El-Fouly
Khaled Ali Al JaafariKhaled Ali Al Jaafari
Khaled Ali Al Jaafari
Nowadays, multilevel inverters (MLIs) are gaining huge popularity for high power transformerless PV applications. Among the traditional MLIs, the cascaded H-bridge (CHB) MLI accommodates lower voltage rated input dc sources, which reduce the voltage stress across the devices. However, the CHB MLI requires multiple PV sources as separate dc-link voltage sources, which create more paths for leakage currents. Therefore, it is a challenging task to deal with the leakage currents in the case of CHB MLIs. In this article, a novel three-phase transformerless inverter topology for grid-connected solar PV application is introduced. This proposed that the inverter topology has six switches per phase, and it has the combined advantages of dc-bypass and ac-bypass circuit configurations. A new modulation strategy is developed for the proposed topology; it is based on a sine triangle pulsewidth modulation technique combined with the dedicated logic functions. The gate pulses for all switches are provided by using these dedicated logic functions. The switching pulses obtained from the dedicated logic functions control all the inverter switches so that the variation of common-mode voltage (CMV) is constant during the inverter operation. This results in reduced leakage current throughout the operation of the inverter. The theoretical analysis, simulations, and experimental results are presented to validate the proposed topology concept for a 3-kVA grid-connected system. Both the simulation and experimental results show that the proposed solution can well attenuate the leakage current; all the results are presented in the article.

4 June 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
PCPhani Kumar Chamarthi
Phani Kumar Chamarthi
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
MMMohamed Shawky El Moursi
Mohamed Shawky El Moursi
Ahmed Al-DurraAhmed Al-Durra
Ahmed Al-Durra
AAAmeena Alsumaiti
Ameena Alsumaiti
KHKhalifa Al Hosani
Khalifa Al Hosani
Multilevel inverter (MLI) design for high voltage and high power applications faces challenges such as unequal power losses and junction temperatures. To address the issues of decreased efficiency and reliability, this paper introduces two innovative pulse width modulation (PWM) approaches, such as Enhanced Level Shifted PWM (ELS-PWM) and Enhanced Phase Shifted PWM (EPS-PWM). They are designed for five-level neutral point clamped (NPC) H-Bridge Configurations (FLNPCHC), which are further cascaded to form MLIs. These methods leverage modified modulating waves and restructured triangular waves to improve power quality, balance power distribution, and ensure uniform power allocation across the inverter legs. The result is identical switch utilization rates, reduced switching times, lower junction temperatures, and enhanced overall efficiency of the FLNPCHC-MLI. These approaches are validated through MATLAB simulations and tested using a 1 kVA laboratory prototype. The outcomes demonstrate significant improvements in total harmonic distortion (reduced to approximately 2.3%) and efficiency (increased to approximately 97.8%), offering a promising solution for high-voltage applications.

12 June 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CPChamarthi Phanikumar
Chamarthi Phanikumar
JRJibanesh Roy
Jibanesh Roy
VAVivek Agarwal
Vivek Agarwal
A 1-$\oslash$ hybrid 9-level inverter (H9LI) topology has been proposed in this paper. The proposed H9LI topology uses a simple phase disposition pulse width modulation (PDPWM) strategy to generate 9-voltage levels in the output. The main advantage of this topology is that it has a low switch count (ten switches) compared to the existing 9-level inverter topologies. To regulate the voltage across an auxiliary capacitor, two innovative control techniques are proposed which are integrated with the inverter modulation technique itself. Hence, it doesn't require any extra voltage balancing circuits to maintain the voltage across the auxiliary capacitor and input DC capacitors. A major advantage of these control techniques is that they eliminate the sensing of the coupled inductor current. Another significant advantage of H9LI is that loss distribution among all the power switches is more uniform compared to existing 9-level inverters. Due to low part count and absence of extra voltage balancing circuits, the H9LI achieves higher efficiency ($\eta\approx$94.5%) and lower cost. Further, the requirement of filter size reduces due to the presence of coupled inductor in H9LI. The proposed 1-$\oslash$ grid connected H9LI is verified through MATLAB/Simulink simulations and validated through experiments on a laboratory prototype of 400VA rating.

29 June 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PCPhanikumar Chamarthi
Phanikumar Chamarthi
PCPawan Chhetri
Pawan Chhetri
VAVivek Agarwal
Vivek Agarwal
Space vector modulation (SVM) control of multilevel inverters (MLIs) is very popular. However, it gets extremely challenging with the increase in the number of output voltage levels due to the emergence of subtriangles in the various sectors of the hexagon, which results in increased computational complexity and storage requirements of switching states and corresponding pulse durations. Currently, this is handled through laborios offline computations in conjunction with the visual inspection of the space vector hexagon and its various sectors. This paper aims to simplify the implementation of the SVM scheme for an n-level MLI by proposing generalized equations that not only facilitate direct online computation of control pulses and obviate the requirement of lookup tables but also result in optimized switching. Yet, the on-time computations of the various MLI switches are still based on simple two-dimensional Cartesian co-ordinate system combined with the basic two-level inverter implementation. The proposed scheme makes use of a unique l-factor approach, which directly identifies the location of the various subtriangles in the space vector hexagon and leads to direct online computations of the control pulses. The proposed scheme is validated by simulations and experimental results for three- and five-level diode clamped MLI.

22 June 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
PCPhani Kumar Chamarthi
Phani Kumar Chamarthi
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
MMMohamed Shawky El Moursi
Mohamed Shawky El Moursi
Ahmed Al-DurraAhmed Al-Durra
Ahmed Al-Durra
VKVinod Khadkikar
Vinod Khadkikar
TETarek H. M. El-Fouly
Tarek H. M. El-Fouly
Inverter topologies for integrating a rooftop photovoltaic (PV) unit into a microgrid are becoming increasingly complex. This paper proposes a high-voltage boosting transformerless inverter (HVBTI) topology for enhancing such applications. The coupled inductor-based high voltage gain feature of the HVBTI configuration allows power to be delivered into the grid from a lower voltage PV source without using higher duties. In addition, HVBTI suppresses leakage current as the common connection shared between the $-ve$ terminal of the PV source and the grid neutral point. In comparison to existing topologies, the HVBTI topology uses a compact pulse width modulation strategy to control only six controllable switching devices. Again, using lower-rated switching devices is more cost-effective while increasing reliability and efficiency. In a laboratory prototype of a 1 kVA grid integrated system, the proposed HVBTI configuration is validated, and the maximum efficiency of the HVBTI is estimated at approximately 95%.