Thin film electrodes are becoming increasingly common for interfacing with tissue. However, their long‐term stability has yet to be proven in neuromodulation applications where electrical stimulation over months to years is desired. Here, the stability of pristine and PEDOT:PSS‐coated Au, as well as pristine PEDOT:PSS microelectrodes are examined over a period of 3 months in an accelerated aging setup where they are exposed to current stimulation, hydrogen peroxide, mechanical agitation, and high temperature. Pristine PEDOT:PSS electrodes show the highest stability, while pristine Au electrodes show the lowest stability. Failure mode analysis reveals that delamination and Au corrosion are the key drivers of electrode degradation. The PEDOT:PSS coating slows down Au corrosion to a degree that depends on the overlap between the two films. The results demonstrate that pristine PEDOT:PSS electrodes represent a promising way forward toward thin film devices for long‐term in vivo neuromodulation applications.
Implantable devices interfacing with peripheral nerves exhibit limited longevity and resolution. Poor nerve-electrode interface quality, invasive surgical placement and development of foreign body reaction combine to limit research and clinical application of these devices. Here, we develop cuff implants with a conformable design that achieve high-quality and stable interfacing with nerves in chronic implantation scenarios. When implanted in sensorimotor nerves of the arm in awake rats for 21 days, the devices record nerve action potentials with fascicle-specific resolution and extract from these the conduction velocity and direction of propagation. The cuffs exhibit high biocompatibility, producing lower levels of fibrotic scarring than clinically equivalent PDMS silicone cuffs. In addition to recording nerve activity, the devices are able to modulate nerve activity at sub-nerve resolution to produce a wide range of paw movements. When used in a partial nerve ligation rodent model, the cuffs identify and characterise changes in nerve C fibre activity associated with the development of neuropathic pain in freely-moving animals. The developed implantable devices represent a platform enabling new forms of fine nerve signal sensing and modulation, with applications in physiology research and closed-loop therapeutics.
The addition of small amounts of xanthate can turn conventional RAFT polymerizations into rapid photo-activated reactions with high livingness, oxygen tolerance and versatility enabling straightforward multiblock synthesis or well plate screening.
23 March 2018 in Angewandte Chemie International Edition