Matt J. Owen

Matt J. Owen

Auto-generated profile, based on publicly available information

Matt J. Owen

Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, United Kingdom

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Journal of Thrombosis and Haemostasis
Verified
Journal Article
Open access
MOMatt J. Owen
Matt J. Owen
JWJoy R. Wright
Joy R. Wright
ETEdward G.D. Tuddenham
Edward G.D. Tuddenham
JKJohn R. King
John R. King
AGAlison H. Goodall
Alison H. Goodall
JDJoanne L. Dunster
Joanne L. Dunster
Mathematical models of coagulation have been developed to mirror thrombin generation in plasma, with the aim of investigating how variation in coagulation factor levels regulates hemostasis. However, current models vary in the reactions they capture and the reaction rates used, and their validation is restricted by a lack of large coherent datasets, resulting in questioning of their utility. To address this debate, we systematically assessed current models against a large dataset, using plasma coagulation factor levels from 348 individuals with normal hemostasis to identify the causes of these variations. We compared model predictions with measured thrombin generation, quantifying and comparing the ability of each model to predict thrombin generation, the contributions of the individual reactions, and their dependence on reaction rates. We found that no current model predicted the hemostatic response across the whole cohort and all produced thrombin generation curves that did not resemble those obtained experimentally. Our analysis has identified the key reactions that lead to differential model predictions, where experimental uncertainty leads to variability in predictions, and we determined reactions that have a high influence on measured thrombin generation, such as the contribution of factor XI. This systematic assessment of models of coagulation, using large dataset inputs, points to ways in which these models can be improved. A model that accurately reflects the effects of the multiple subtle variations in an individual's hemostatic profile could be used for assessing antithrombotics or as a tool for precision medicine.

24 May 2019 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PDF file
ACAntonio Francesco Corno
Antonio Francesco Corno
MOMatt J. Owen
Matt J. Owen
ACAndrea Cangiani
Andrea Cangiani
EHEdward J. C. Hall
Edward J. C. Hall
ARAldo Rona
Aldo Rona
Objective: The conventional Fontan circulation deviates the superior vena cava (SVC = 1/3 of the systemic venous return) toward the right lung (3/5 of total lung volume) and the inferior vena cava (IVC = 2/3 of the systemic venous return) toward the left lung (2/5 of total lung volume). A “physiological” Fontan deviating the SVC toward the left lung and the IVC toward the right lung was compared with the conventional setting by computational fluid dynamics, studying whether this setting achieves a more favorable hemodynamics than the conventional Fontan circulation. Materials and Methods: An in-silico 3D parametric model of the Fontan procedure was developed using idealized vascular geometries with invariant sizes of SVC, IVC, right pulmonary artery (RPA), and left pulmonary artery (LPA), steady inflow velocities at IVC and SVC, and constant equal outflow pressures at RPA and LPA. These parameters were set to perform finite-volume incompressible steady flow simulations, assuming a single-phase, Newtonian, isothermal, laminar blood flow. Numerically converged finite-volume mass and momentum flow balances determined the inlet pressures and the outflow rates. Numerical closed-path integration of energy fluxes across domain boundaries determined the flow energy loss rate through the Fontan circulation. The comparison evaluated: (1) mean IVC pressure; (2) energy loss rate; (3) kinetic energy maximum value throughout the domain volume. Results: The comparison of the physiological vs. conventional Fontan provided these results: (1) mean IVC pressure 13.9 vs. 14.1 mmHg (= 0.2 mmHg reduction); (2) energy loss rate 5.55 vs. 6.61 mW (= 16% reduction); (3) maximum kinetic energy 283 vs. 396 J/m3 (= 29% reduction). Conclusions: A more physiological flow distribution is accompanied by a reduction of mean IVC pressure and by substantial reductions of energy loss rate and of peak kinetic energy. The potential clinical impact of these hemodynamic changes in reducing the incidence and severity of the adverse long-term effects of the Fontan circulation, in particular liver failure and protein-losing enteropathy, still remains to be assessed and will be the subject of future work.

14 August 2025 in PLOS Computational Biology
Verified
Journal Article
Open access
MOMatt J. Owen
Matt J. Owen
GMGary Richard Mirams
Gary Richard Mirams
Ion channel models present many challenging optimisation problems. These include unidentifiable parameters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori. Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation benchmarking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.

31 January 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
MOMatt J. Owen
Matt J. Owen
GMGary Richard Mirams
Gary Richard Mirams
Ion channel models present many challenging optimisation problems. These include unidentifiable parame- ters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori . Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation bench- marking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.