Conventional manual ultrasound (US) imaging is a physically demanding procedure for sonographers. A robotic US system (RUSS) has the potential to overcome this limitation by automating and standardizing the imaging procedure. It also extends ultrasound accessibility in resource-limited environments with the shortage of human operators by enabling remote diagnosis. During imaging, keeping the US probe normal to the skin surface largely benefits the US image quality. However, an autonomous, real-time, low-cost method to align the probe towards the direction orthogonal to the skin surface without pre-operative information is absent in RUSS. We propose a novel end-effector design to achieve self-normal-positioning of the US probe. The end-effector embeds four laser distance sensors to estimate the desired rotation towards the normal direction. We then integrate the proposed end-effector with a RUSS system which allows the probe to be automatically and dynamically kept to normal direction during US imaging. We evaluated the normal positioning accuracy and the US image quality using a flat surface phantom, an upper torso mannequin, and a lung ultrasound phantom. Results show that the normal positioning accuracy is 4.17 $\pm$ 2.24 degrees on the flat surface and 14.67 $\pm$ 8.46 degrees on the mannequin. The quality of the RUSS collected US images from the lung ultrasound phantom was equivalent to that of the manually collected ones.
1 August 2025 in IEEE Robotics and Automation Letters
Conventional freehand ultrasound (US) imaging is highly dependent on the skill of the operator, leading to inconsistent results and increased physical burden on sonographers. Robotic Ultrasound Systems (RUSS) aim to address these limitations by providing standardized and automated imaging solutions, especially in environments with limited access to skilled operators. This letter presents the development of a RUSS system that employs a novel end-effector, A-SEE2.0, which uses dual RGB-D depth cameras to maintain the US probe normal to the skin surface, a default starting configuration for anatomical landmarks identification. Our RUSS integrates RGB-D camera data with robotic control algorithms to maintain orthogonal probe alignment on uneven surfaces without preoperative data. Validation tests using a phantom model show that the system achieves robust normal positioning accuracy. A-SEE2.0 demonstrates 2.47 ± 1.25 degrees normal positioning error on a flat surface and 12.19 ± 5.81 degrees error on a mannequin surface. This work highlights the clinical potential of A-SEE2.0 by demonstrating that, during in-vivo forearm ultrasound examinations, it achieves image quality comparable to manual scanning by a human sonographer.