18 May 2011 in Plasma Physics and Controlled Fusion
23 August 2018 in Review of Scientific Instruments
An in situ wavelength calibration system for the X-ray Imaging Crystal Spectrometer (XICS) on W7-X has been developed to provide routine calibration between plasma shots. XICS is able to determine plasma flow profiles by measuring the Doppler shift of x-ray line emission from highly charged impurity species. A novel design is described that uses an x-ray tube with a cadmium anode placed in front of the diffracting spherically bent crystal. This arrangement provides calibration lines over the full detector extent for both the Ar16+ and Ar17+/Fe24+ spectrometer channels. This calibration system can provide a relative wavelength accuracy of 3 × 10−7 Å across the full spatial extent of the detector, which corresponds to 50 m/s in the W7-X system. An absolute wavelength calibration of 1 × 10−5 Å is expected, corresponding to 1 km/s, based on the current known accuracy of the calibration wavelength and the achievable measurement of the absolute positioning of the hardware. This calibration system can be used to independently calibrate XICS systems on both stellarators and tokamaks, without the need for special plasma conditions often used for calibration, such as locked modes on tokamaks. Experimental and simulated results are shown along with expected results, and the complete design of the calibration hardware that is to be installed in the W7-X XICS system.
1 September 2016 in Physics of Plasmas
Numerical MHD simulations are used to gain insight into how sawteeth are affected by three-dimensional shaping from the Compact Toroidal Hybrid (CTH) stellarator field. CTH is a small stellarator-tokamak hybrid and sawteeth are sometimes seen on soft x-ray signals when operating with tokamak like profiles. We use NIMROD to compute numerical solutions having repeated sawtooth relaxations for a sequence of configurations with increasing helical stellarator field strength. The experimentally observed trend of the sawtooth period decreasing as the helical field strength is increased is recovered in the simulations. Careful attention to numerical convergence was required to obtain the results, and these considerations may be relevant to simulations of other phenomena in devices with non-axisymmetric plasmas such as perturbed tokamaks, RFPs, and stellarators.
1 August 2008 in Physics of Plasmas
The authors report on the first experimental demonstration of active feedback suppression of rotating external kink modes near the ideal wall limit in a tokamak using Kalman filtering to discriminate the kink mode from background noise. The Kalman filter contains an internal model that captures the dynamics of a rotating, growing mode. Suppression of the external kink mode is demonstrated over a broad range of phase angles between the sensed mode and applied control field, and performance is robust at noise levels that render proportional gain feedback ineffective. Suppression of the kink mode is accomplished without excitation of higher frequencies as was observed in previous experiments using lead-lag loop compensation [A. J. Klein et al., Phys Plasmas 12, 040703 (2005)].
1 July 2024 in Review of Scientific Instruments
A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C2+ impurity ion temperature Ti spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain Ti in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The Ti-optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer Ti profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the Ti distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with Ti ranging between 10 and 40 eV.
1 January 2018 in Physics of Plasmas
Collimated soft X-ray (SXR) emissivity measurements from multi-channel cameras on the Compact Toroidal Hybrid (CTH) tokamak/torsatron device are incorporated in the 3D equilibrium reconstruction code V3FIT to reconstruct the shape of flux surfaces and infer the current distribution within the plasma. Equilibrium reconstructions of sawtoothing plasmas that use data from both SXR and external magnetic diagnostics show the central safety factor to be near unity under the assumption that SXR iso-emissivity contours lie on magnetic flux surfaces. The reconstruction results are consistent with those using the external magnetic data and a constraint on the location of q = 1 surfaces determined from the sawtooth inversion surface extracted from SXR brightness profiles. The agreement justifies the use of approximating SXR emission as a flux function in CTH, at least within the core of the plasma, subject to the spatial resolution of the SXR diagnostics. This improved reconstruction of the central current density indicates that the current profile peakedness decreases with increasing external transform and that the internal inductance is not a relevant measure of how peaked the current profile is in hybrid discharges.