29 August 2024 in npj Flexible Electronics
Twenty-four hours continuous intraocular pressure (IOP) monitoring is beneficial for glaucoma care. Contact lens sensors using LC technology can achieve non-invasive continuous IOP measuring around the clock and are relatively simple in principle and structure, thus dominating the mainstream. Among them, stretchable inductive LC contact lens sensors constructed with liquid metal have advantages in signal quality as well as wearing comfort, but currently its sensitivity is slightly insufficient. Here, we propose an LC sensor that constructed with liquid metal to form the stretchable inductance and capacitance further. The capacitive plate and inductive coil can response to IOP changes simultaneously, thus able to enhance the sensitivity in principle. We modeled the sensing mechanism and conducted design, fabrication, as well as various tests. The device exhibits good characteristics, including reliability, good signal quality, etc. Especially, it has a threefold increase in sensitivity, exceeding the current state-of-the-art contact lens sensors.
12 November 2024 in Measurement Science and Technology
LC resonant wireless passive intraocular pressure (IOP) sensors measure IOPs by mapping them to LC resonance frequencies. However, during the sweeping acquisition process of each LC signal frame, possible rapid eye movement (REM) can interfere with the wireless mutual inductance coupling, leading to the signal distortion and resulting in the error of resonance frequency measuring. Currently, there is a lack of modelling analysis of the errors generated by REM effect, resulting in an absence of guidance for reducing the impact. Therefore, here, we start from the perspective of the signal model and establish the LC dynamic signal model for sweeping acquisition. By means of the limit state analysis and Monte Carlo simulation, we analyze the influence of external REM parameters (including REM range and velocity) and internal parameters of the LC sensing system (including the quality coefficient of LC sensor, diameter, and number of turns of the reader coil, signal sweep acquisition speed and period) on the errors. We demonstrated theoretical relationship between the extreme errors with these parameters and verify it through a computer simulation. Based on the results, we propose to optimize the internal parameters of the LC sensing system to reduce the REMs effect on errors, safeguarding the quality of signal acquisition and improving the measurement accuracy.