Introduction: Several single-center studies and meta-analyses have shown that perioperative goal-directed therapy may significantly improve outcomes in general surgical patients. We hypothesized that using a treatment algorithm based on pulse pressure variation, cardiac index trending by radial artery pulse contour analysis, and mean arterial pressure in a study group (SG), would result in reduced complications, reduced length of hospital stay and quicker return of bowel movement postoperatively in abdominal surgical patients, when compared to a control group (CG). Methods: 160 patients undergoing elective major abdominal surgery were randomized to the SG (79 patients) or to the CG (81 patients). In the SG hemodynamic therapy was guided by pulse pressure variation, cardiac index trending and mean arterial pressure. In the CG hemodynamic therapy was performed at the discretion of the treating anesthesiologist. Outcome data were recorded up to 28 days postoperatively. Results: The total number of complications was significantly lower in the SG (72 vs. 52 complications, p = 0.038). In particular, infection complications were significantly reduced (SG: 13 vs. CG: 26 complications, p = 0.023). There were no significant differences between the two groups for return of bowel movement (SG: 3 vs. CG: 2 days postoperatively, p = 0.316), duration of post anesthesia care unit stay (SG: 180 vs. CG: 180 minutes, p = 0.516) or length of hospital stay (SG: 11 vs. CG: 10 days, p = 0.929). Conclusions: This multi-center study demonstrates that hemodynamic goal-directed therapy using pulse pressure variation, cardiac index trending and mean arterial pressure as the key parameters leads to a decrease in postoperative complications in patients undergoing major abdominal surgery. Trial registration: ClinicalTrial.gov, NCT01401283.
Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical conditions is warranted. The aim of our study was to compare the reliability of a novel system for cardiac index (CI) monitoring based on uncalibrated pulse contour analysis (UPCA) with transpulmonary thermodilution (TPTD) during off-pump coronary artery bypass grafting (OPCAB). Twenty patients undergoing elective OPCAB were enrolled into the study. CI measured by means of UPCA (CIUPCA) was validated against CI determined with TPTD technique (CITPTD). Parallel measurements of CI were performed at nine stages during the surgery and after operation. We assessed the accuracy and the precision of individual values and the agreement of trends of changes in CI. Totally, 180 pairs of data were collected. There was a significant correlation between CIUPCA and CITPTD (ρ=0.836, P<0.01). According to a Bland–Altman analysis, the mean bias between the methods was −0.14 litre min−1 m−2 with limits of agreement of ±0.82 litre min−1 m−2 and a percentage error of 31%. A polar plot trend analysis revealed acceptable angular bias (−0.54°), increased radial limits of agreement (±52.7°), and decreased polar concordance rate (74%). In OPCAB, UPCA provides accurate and precise CI measurements compared with TPTD. However, the ability of this method to follow trends in cardiac output is poor. NCT01773720 (ClinicalTrials.gov).
7 March 2016 in Journal of Clinical Monitoring and Computing