Background: The aim of this study is to determine the influence of field of view (FOV) and number of acquisition projection images (frames) on the detection of chemically simulated peri‐implant defects by cone‐beam computed tomography (CBCT) using an in vitro bovine rib bone model.Methods: Eighty implants were placed in bovine ribs in which small and large bone defects were created using 70% perchloric acid. CBCT images were acquired at three acquisition protocols: protocol 1 (FOV 4 × 4 cm, 0.08‐mm voxel size, 1,009 frames [high fidelity]; protocol 2 (same as protocol 1 except 512 frames [standard]); and protocol 3 (FOV 14 × 5 cm, 0.25‐mm voxel size; high fidelity). Two oral and maxillofacial radiologists (OMRs) and two oral and maxillofacial surgeons (OMSs) rated the presence or absence of bone defects on a five‐point scale. κ and area under the curve (AUC) were calculated and compared using analysis of variance with post hoc Tukey test at P ≤0.05.Results: Intra‐ and interobserver agreement for OMRs ranged from moderate to good and from slight to moderate for OMSs. For the detection of small lesions, protocol 1 (AUC 0.813 ± 0.045) provided higher detection rates than protocol 2 (AUC 0.703 ± 0.02) and protocol 3 (AUC 0.773 ± 0.55) [F(2,9) = 1.6377]. For larger defects, the trends were similar, with protocol 1 (AUC 0.852 ± 0.108) providing higher detection rates than protocol 2 (AUC 0.730 ± 0.045) and protocol 3 (AUC 0.783 ± 0.058) [F(2,9) = 1.9576].Conclusion: Within the limits of this study, optimal detection of chemically simulated pericircumferential implant crestal bone defects is achieved at the least radiation detriment using the smallest FOV, the highest number of acquisition frames, and the smallest voxel.
Bifid mandibular condyle is an uncommon entity described in the literature as having a controversial etiology. Despite the absence of clinical symptomatology, the radiologist must be aware and should have some knowledge of this abnormality, as well its implications regarding functional and morphological changes. TMJ ankylosis is a disabling disease with involvement of the mandibular condyle, articular fossa and base of the skull. The association of bifid condyle with temporomandibular joint ankylosis is rare and must be carefully evaluated. The purpose of this paper is to report a case of simultaneous bifid mandibular condyle and temporomandibular joint ankylosis and to describe its computed tomography imaging findings.
There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis.
1 March 2008 in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology