19 March 2012 in International Journal of Low-Carbon Technologies
Water thermal stratification exists in the discharging process of solar storage tanks, and a high efficiency of thermal stratification can greatly improve the discharging performance of solar tanks. The water tank with dimensions of 0.8 m (height) × 0.4 m (width) × 0.4 m (length) and three kinds of inlet structures were investigated in this study. The inlets included a perforated inlet, slotted inlet and direct inlet. The discharging performance of the tank was studied by presenting some compared experiments. The dimensionless discharging time was defined to analyze the temperature change of top-layer and inter-layer of water. Quantitative analysis and comparison based on the effective discharging efficiency and carbon reduction in the tank with different inlet structures were carried out in this study. The results indicated that the perforated inlet and slotted inlet improved the performance of thermal stratification effectively. The effective discharging efficiency of the perforated inlet structure was 21% higher than that of a direct inlet with the flow rate of 5 l/min and the gap increased to 40% when the flow rate increased to 15 l/min. The application of the perforated inlet tank in the discharging process in all solar water heaters in China can provide a CO2 reduction of 5.39 × 104t compared with the direct inlet tank.
5 September 2013 in International Journal of Low-Carbon Technologies
A new CO2 cryogenic capture and liquefaction system has been proposed previously in order to separate CO2 from exhausted gases and make it as a resource for industry. This system combines CO2 cryogenic capture with N2/O2 separation together. Its energy consumption is lower than the traditional amine solution capture process as theoretical analysis. In this study, the simulation of the proposed system with several improvements was carried out aiming to reduce the energy consumption further. Many heat exchangers were introduced and the heat exchanger arrangements were optimized to recycle the refrigeration capacity from the returned N2 after the N2/O2 separation. The discharge pressure of mixture gas from the compressor was reduced from 10 to 3.493 MPa. The simulation results showed that the compression work could be greatly reduced and the energy consumption of CO2 capture in this new system after these improvements reached 2.884 GJ/ton CO2. The new system is promising because not only liquid or solid CO2 could be produced but also N2 and O2 could be separated.