In this paper, the procedure for determination of the mean value of non-homogenous background radiation and the expression of measurement uncertainty is considered. The background radiation is described using the Student's distribution, and the measurement uncertainty using the Welch-Satterthwaite equation. The proposed algorithm was experimentally verified under well-controlled laboratory conditions and satisfactory results were obtained.
In this paper, the aging effect of commercially available Geiger-Muller counters under working conditions is being considered from both theoretical and experimental point of view. In the experimental part lifetime curves for the commercial Geiger-Muller counter chamber are first recorded. After detection of the aging phenomena, the commercial chamber response to an impulse voltage is tested along with recording of the same response of the Geiger-Muller chamber model with conductive particles included. The law of similarity for the gaseous discharge is fulfilled both by the commercial Geiger-Muller chamber and by the chamber model with conductive particles. The results obtained from the U-test indicate that the aging of the Geiger-Muller chamber is mainly caused by the occurrence of a great number of conductive particles hovering inside the chamber. Some suggestions of how to reduce the aging effect due to conductive particles inside the Geiger-Muller chamber are given in the conclusion.
19 February 2010 in Folia Histochemica et Cytobiologica
Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal "images" are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph.