Nicola Martino

Nicola Martino

Auto-generated profile, based on publicly available information

Nicola Martino

Wellman Center for Photomedicine, Massachusetts General Hospital, Cambridge, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2019 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
NMNicola Martino
Nicola Martino
SKSheldon J. J. Kwok
Sheldon J. J. Kwok
ALAndreas C. Liapis
Andreas C. Liapis
SFSarah Forward
Sarah Forward
HJHoon Jang
Hoon Jang
SYSeok-Hyun Yun
Seok-Hyun Yun

25 January 2021 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
STShui-Jing Tang
Shui-Jing Tang
PDPaul H. Dannenberg
Paul H. Dannenberg
ALAndreas C. Liapis
Andreas C. Liapis
NMNicola Martino
Nicola Martino
YZYue Zhuo
Yue Zhuo
SYSeok-Hyun Yun
Seok-Hyun Yun
The ability to track individual cells in space over time is crucial to analyzing heterogeneous cell populations. Recently, microlaser particles have emerged as unique optical probes for massively multiplexed single-cell tagging. However, the microlaser far-field emission is inherently direction-dependent, which causes strong intensity fluctuations when the orientation of the particle varies randomly inside cells. Here, we demonstrate a general solution based on the incorporation of nanoscale light scatterers into microlasers. Two schemes are developed by introducing either boundary defects or a scattering layer into microdisk lasers. The resulting laser output is omnidirectional, with the minimum-to-maximum ratio of the angle-dependent intensity improving from 0.007 (−24 dB) to > 0.23 (−6 dB). After transfer into live cells in vitro, the omnidirectional laser particles within moving cells could be tracked continuously with high signal-to-noise ratios for 2 h, while conventional microlasers exhibited frequent signal loss causing tracking failure.

30 November 2023 in Nature Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SKSheldon J. J. Kwok
Sheldon J. J. Kwok
SFSarah Forward
Sarah Forward
MFMarissa D. Fahlberg
Marissa D. Fahlberg
EAEmane Rose Assita
Emane Rose Assita
SCSean Cosgriff
Sean Cosgriff
SYSeok-Hyun Yun
Seok-Hyun Yun
Advances in immunology, immuno-oncology, drug discovery and vaccine development demand improvements in the capabilities of flow cytometry to allow it to measure more protein markers per cell at multiple timepoints. However, the size of panels of fluorophore markers is limited by overlaps in fluorescence-emission spectra, and flow cytometers typically perform cell measurements at one timepoint. Here we describe multi-pass high-dimensional flow cytometry, a method leveraging cellular barcoding via microparticles emitting near-infrared laser light to track and repeatedly measure each cell using more markers and fewer colours. By using live human peripheral blood mononuclear cells, we show that the method enables the time-resolved characterization of the same cells before and after stimulation, their analysis via a 10-marker panel with minimal compensation for spectral spillover and their deep immunophenotyping via a 32-marker panel, where the same cells are analysed in 3 back-to-back cycles with 10–13 markers per cycle, reducing overall spillover and simplifying marker-panel design. Cellular barcoding in flow cytometry extends the utility of the technique for high-dimensional multi-pass single-cell analyses.

21 August 2019 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
SKSheldon J. J. Kwok
Sheldon J. J. Kwok
NMNicola Martino
Nicola Martino
PDPaul H. Dannenberg
Paul H. Dannenberg
SYSeok-Hyun Yun
Seok-Hyun Yun
Biomolecular analysis at the single-cell level is increasingly important in the study of cellular heterogeneity and its consequences, particularly in organismic development and complex diseases such as cancer. Single-cell molecular analyses have led to the identification of new cell types1 and the discovery of novel targets for diagnosis and therapy2. While these analyses are performed predominantly on dissociated single cells, emerging techniques seek understanding of cellular state, cellular function and cell–cell interactions within the native tissue environment by combining optical microscopy and single-cell molecular analyses. These techniques include in situ multiplexed imaging of fluorescently labeled proteins and nucleotides, as well as low-throughput ex vivo methods in which specific cells are isolated for downstream molecular analyses. However, these methods are limited in either the number and type of molecular species they can identify or the number of cells that can be analyzed. High-throughput methods are needed for comprehensive profiling of many cells (>1000) to detect rare cell types, discriminate relevant biomarkers from intrinsic population noise, and reduce the time and cost of measurement. Many established, high-throughput single-cell analyses are not directly applicable because they require tissue dissociation, leading to a loss of spatial information3. No current methods exist that can seamlessly connect spatial mapping to single-cell techniques. In this Perspective, we review current methods for spatially resolved single-cell analysis and discuss the prospect of novel multiplexed imaging probes, called laser particles, which allow individual cells to be tagged in tissue and analyzed subsequently using high-throughput, comprehensive single-cell techniques.

17 February 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
SRSeungmi Ryu
Seungmi Ryu
NMNicola Martino
Nicola Martino
SKSheldon J. J. Kwok
Sheldon J. J. Kwok
LBLiane Bernstein
Liane Bernstein
SYSeok-Hyun Yun
Seok-Hyun Yun
Brillouin light scattering offers a unique label-free approach to measure biomechanical properties non-invasively. While this technique is used in biomechanical analysis of cells and tissues, its potential for visualizing structural features of tissues based on the biomechanical contrast has not been much exploited. Here, we present high-resolution Brillouin microscopy images of four basic tissue types: muscular, connective, epithelial, and nervous tissues. The Brillouin contrast distinguishes between muscle fiber cells and endomysium in skeletal muscle and reveals chondrocytes along with spatially varying stiffness of the extracellular matrix in articular cartilage. The hydration-sensitive contrast can visualize the stratum corneum, epidermis, and dermis in the skin epithelium. In brain tissues, the Brillouin images show the mechanical heterogeneity across the cortex and deeper regions. This work demonstrates the versatility of using the Brillouin shift as histological contrast for examining intact tissue substructures via longitudinal modulus without the need for laborious tissue processing steps.

27 May 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
PDPaul H. Dannenberg
Paul H. Dannenberg
JKJisoo Kang
Jisoo Kang
NMNicola Martino
Nicola Martino
AKAnokhi Kashiparekh
Anokhi Kashiparekh
SFSarah Forward
Sarah Forward
SYSeok-Hyun Yun
Seok-Hyun Yun
A microfluidic device is developed that uses the narrowband optical radiation of laser particle barcodes to sort tagged cells.