Woo-Jin Chang

Woo-Jin Chang

Auto-generated profile, based on publicly available information

Woo-Jin Chang

University of Wisconsin-Milwaukee

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TKTae Joon Kwak
Tae Joon Kwak
YNYoung Gyu Nam
Young Gyu Nam
MNMaria Alejandra Najera
Maria Alejandra Najera
SLSang Woo Lee
Sang Woo Lee
JSJ. Rudi Strickler
J. Rudi Strickler
WCWoo-Jin Chang
Woo-Jin Chang
The liquid streams in a microchannel are hardly mixed to form laminar flow, and the mixing issue is well described by a low Reynolds number scheme. The staggered herringbone mixer (SHM) using repeated patterns of grooves in the microchannel have been proved to be an efficient passive micro-mixer. However, only a negative pattern of the staggered herringbone mixer has been used so far after it was first suggested, to the best of our knowledge. In this study, the mixing efficiencies from negative and positive staggered herringbone mixer patterns as well as from opposite flow directions were tested to investigate the effect of the micro-structure geometry on the surrounding laminar flow. The positive herringbone pattern showed better mixing efficiency than the conventionally used negative pattern. Also, generally used forward flow gives better mixing efficiency than reverse flow. The mixing was completed after two cycles of staggered herringbone mixer with both forward and reverse flow in a positive pattern. The traditional negative pattern showed complete mixing after four and five cycles in forward and reverse flow direction, respectively. The mixing effect in all geometries was numerically simulated, and the results confirmed more efficient mixing in the positive pattern than the negative. The results can further enable the design of a more efficient microfluidic mixer, as well as in depth understanding of the phenomena of positive and negative patterns existing in nature with regards to the surrounding fluids.

19 October 2016 in ACS Sensors
Verified
Journal Article
Closed access
JYJiang Yang
Jiang Yang
TKTae Joon Kwak
Tae Joon Kwak
XZXiaodong Zhang
Xiaodong Zhang
RMRobert McClain
Robert McClain
WCWoo-Jin Chang
Woo-Jin Chang
Sundaram GunaekaranSundaram Gunaekaran
Sundaram Gunaekaran

22 December 2014 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
NYNael G Yasri
Nael G Yasri
Ashok K. SundramoorthyAshok K. Sundramoorthy
Ashok K. Sundramoorthy
WCWoo-Jin Chang
Woo-Jin Chang
Sundaram GunaekaranSundaram Gunaekaran
Sundaram Gunaekaran
Partially oxidized graphene flakes (po-Gr) were obtained from graphite electrode by an electrochemical exfoliation method. As-produced po-Gr flakes were dispersed in water with the assistance of poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT:PSS). The po-Gr flakes and the po-Gr/PEDOT:PSS nanocomposite (po-Gr/PEDOT:PSS) were characterized by Raman spectroscopy, Fourier transform-infrared spectroscopy (FT-IR), UV-Vis spectroscopy, X-ray diffraction (XRD) and scanning electron microscopy (SEM). In addition, we demonstrated the potential use of po-Gr/PEDOT:PSS electrode in electrochemical detection of mercury ions (Hg2+) in water samples. The presence of po-Gr sheets in PEDOT:PSS film greatly enhanced the electrochemical response for Hg2+. Cyclic voltammetry measurements showed a well-defined Hg2+ redox peaks with a cathodic peak at 0.23 V, and an anodic peak at 0.42 V. Using differential pulse stripping voltammetry, detection of Hg2+ was achieved in the range of 0.2 to 14 µM (R2 = 0.991), with a limit of detection (LOD) of 0.19 µM for Hg2+. The electrode performed satisfactorily for sensitive and selective detection of Hg2+ in real samples, and the po-Gr/PEDOT:PSS film remains stable on the electrode surface for repeated use. Therefore, our method is potentially suitable for routine Hg2+ sensing in environmental water samples.

1 November 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JYJiang Yang
Jiang Yang
YNYoung-Gyu Nam
Young-Gyu Nam
SLSung-Kyun Lee
Sung-Kyun Lee
CKChang-Soo Kim
Chang-Soo Kim
YKYoon-Mo Koo
Yoon-Mo Koo
SGSundaram Gunasekaran
Sundaram Gunasekaran

1 June 2007 in Biotechnology and Bioprocess Engineering
Verified
Journal Article
Closed access
PDF file
SLSang Woo Lee
Sang Woo Lee
WCWoo-Jin Chang
Woo-Jin Chang
RBRashid Bashir
Rashid Bashir
YKYoonmo Koo
Yoonmo Koo

12 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TKTae Joon Kwak
Tae Joon Kwak
IHImtiaz Hossen
Imtiaz Hossen
RBRashid Bashir
Rashid Bashir
WCWoo-Jin Chang
Woo-Jin Chang
CLChung Hoon Lee
Chung Hoon Lee
Temperature increases during dielectrophoresis (DEP) can affect the response of biological entities, and ignoring the effect can result in misleading analysis. The heating mechanism of a DEP device is typically considered to be the result of Joule heating and is overlooked without an appropriate analysis. Our experiment and analysis indicate that the heating mechanism is due to the dielectric loss (Debye relaxation). A temperature increase between interdigitated electrodes (IDEs) has been measured with an integrated micro temperature sensor between IDEs to be as high as 70 °C at 1.5 MHz with a 30 Vpp applied voltage to our ultra-low thermal mass DEP device. Analytical and numerical analysis of the power dissipation due to the dielectric loss are in good agreement with the experiment data.