Tomas Skala

Tomas Skala

Auto-generated profile, based on publicly available information

Tomas Skala

Department of Internal Medicine I - Cardiology, University Hospital Olomouc, Czech Republic

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2021 in Biomedical Papers
Verified
Journal Article
Open access
PDF file
OMOndrej Moravec
Ondrej Moravec
TSTomas Skala
Tomas Skala
OKOlga Klementova
Olga Klementova
JSJitka Skalova
Jitka Skalova
MHMartin Hutyra
Martin Hutyra
MTMilos Taborsky
Milos Taborsky
Background: Catheter ablation of paroxysmal atrial fibrillation (AF) can be performed under general anesthesia or conscious sedation. The influence of type of anesthesiology care on procedural characteristics and ablation outcome in patients i...

19 August 2021 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
MTMilos Táborský
Milos Táborský
TSTomas Skála
Tomas Skála
MLMarie Lazárová
Marie Lazárová
RARenata Aiglová
Renata Aiglová
JŠJindrich Špinar
Jindrich Špinar
ALAleš Linhart
Aleš Linhart
Aims A retrospective nationwide observational analysis of diagnoses, procedures, and treatment reported to the Czech National Registry of Reimbursed Health Services between 2012 and 2018. Methods and results Prevalence of heart failure (HF) patients increased from 176 496 (1679.4 per 100 000 population) in 2012 to 285 745 (2689.0 per 100 000 population) patients in 2018 (mean age 74.4 ± 12.8 years). In the last years, a stable incidence of HF patients was observed (544 per 100 000 population in 2016 vs. 551 per 100 000 population in 2018; P = 0.310). Mortality rate decreased from 20.55% in 2012 to 15.89% in 2018. The number of hospitalized patients remained similar (318.2 per 100 000 population in 2012 vs. 311.8 per 100 000 population in 2018; P = 0.479). The most used drugs were diuretics (173 295; 60.6%) and beta-blockers (178 823; 62.6%), followed by angiotensin-converting enzyme inhibitors/angiotensin II receptor blockers (angiotensin-converting enzyme inhibitors 120.581; 42.2%; angiotensin II receptor blockers 47 216; 16.5%). Even though the whole number of implanted devices in HF patients increased steadily (from 25 205 in 2012 to 45 363 in 2018), the prevalence of all devices (pacemakers and defibrillators) in the HF patients remained about the same (14.3% in 2012; 15.9% in 2018). Conclusions The study included all patients with HF in the Czech Republic. These are the first nationwide data of HF epidemiology in the Eastern bloc. The incidence of HF remains stable in the last years. Due to aging of the population, the prevalence of HF significantly increased in the last 6 years. Despite a continuous increase in the prevalence of HF and a suboptimal utilization of its pharmacological therapy, mortality decreased, and the number of hospitalized patients remained the same.

18 November 2014 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
MHMartin Hutyra
Martin Hutyra
TSTomáš Skála
Tomáš Skála
DHDavid Horák
David Horák
MKMartin Köcher
Martin Köcher
ZTZbyněk Tüdös
Zbyněk Tüdös
MTMiloš Táborský
Miloš Táborský

18 February 2019 in Biomedical Papers
Verified
Journal Article
Open access
PDF file
MTMilos Taborsky
Milos Taborsky
TSTomas Skala
Tomas Skala
MKMartin Kocher
Martin Kocher
MFMarian Fedorco
Marian Fedorco
Background. Leadless pacemakers (PMs) were recently introduced to address the complication rate of standard PMs with transvenous leads. Methods and Results. A 34-year old male with a history of intravenous substance abuse and a chronic type C hepatitis developed a complete atrioventricular block after cardiac surgery for infective endocarditis. Repeatedly, endo-and epi-cardially implanted PMs had to be explanted due to infection. A leadless MICRA pacemaker was successfully implanted with a dislocation into pulmonary artery several days after implantation. The PM was successfully retrieved using a single-loop retrieval snare guided by a steerable sheath. Subsequently, another Micra PM was successfully implanted with no further issues. Conclusion. In the case of a Micra leadless pacemaker dislocation, a conventional gooseneck snare in combination with a steerable sheath can be used to retrieve the device, improving the overall safety of leadless pacemakers.

20 August 2010 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
TSTomas Skala
Tomas Skala
MHMartin Hutyra
Martin Hutyra
JVJan Vaclavik
Jan Vaclavik
MKMilan Kaminek
Milan Kaminek
DHDavid Horak
David Horak
MTMilos Taborsky
Milos Taborsky

13 May 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
SHStepan Havranek
Stepan Havranek
ZFZdenka Fingrova
Zdenka Fingrova
TSTomas Skala
Tomas Skala
ARAdrian Reichenbach
Adrian Reichenbach
MDMilan Dusik
Milan Dusik
DWDan Wichterle
Dan Wichterle
Aims: Atrial fibrillation (AF), typical atrial flutter (AFL), and other atrial tachycardias (ATs) are common in patients with pulmonary hypertension. Frequently, several supraventricular arrhythmias are successively observed in individual patients. We investigated the hypothesis of whether more extensive radiofrequency catheter ablation of the bi-atrial arrhythmogenic substrate instead of clinical arrhythmia ablation alone results in superior clinical outcomes in patients with pulmonary arterial hypertension (PH) and supraventricular arrhythmias. Methods and results: Patients with combined post- and pre-capillary or isolated pre-capillary PH and supraventricular arrhythmia indicated to catheter ablation were enrolled in three centres and randomized 1:1 into two parallel treatment arms. Patients underwent either clinical arrhythmia ablation only (Limited ablation group) or clinical arrhythmia plus substrate-based ablation (Extended ablation group). The primary endpoint was arrhythmia recurrence >30 s without antiarrhythmic drugs after the 3-month blanking period. A total of 77 patients (mean age 67 ± 10 years; 41 males) were enrolled. The presumable clinical arrhythmia was AF in 38 and AT in 36 patients, including typical AFL in 23 patients. During the median follow-up period of 13 (interquartile range: 12; 19) months, the primary endpoint occurred in 15 patients (42%) vs. 17 patients (45%) in the Extended vs. Limited ablation group (hazard ratio: 0.97, 95% confidence interval: 0.49–2.0). There was no excess of procedural complications and clinical follow-up events including an all-cause death in the Extended ablation group. Conclusion: Extensive ablation, compared with a limited approach, was not beneficial in terms of arrhythmia recurrence in patients with AF/AT and PH. Clinical Trials Registration: ClinicalTrials.gov; NCT04053361.