Objectives: To clarify whether the results of repair of a complex mitral lesion (Barlow valve) at the intermediate-term follow-up are independent of the mode of surgical access [minithoracotomy vs. median sternotomy (MS)]. Methods: In a prospective randomized study of mitral repair for Barlow disease using either a minimally invasive (MI) approach or MS, we achieved an average follow-up of 3 years (echocardiography, physical examination and quality of life). Mitral repair was achieved with polytetrafluoroethylene chordal implantation for both leaflets. Results: Both groups included 80 patients. Mechanical ventilation time and intensive care unit and hospital stay were shorter in the MI group (p = 0.01, p = 0.013 and p = 0.02, respectively). During the follow-up, 5 patients in each group (6.25%) displayed mild mitral regurgitation, while 2 patients in each group (2.5%) developed recurrent regurgitation graded as at least moderate/severe. The rate of mitral reoperation was 2.5% in the MI group and 1.25% in the MS group (p = 0.9). The overall follow-up mortality was 3.75% in both the MI and the MS groups. Conclusions: The 3-year results of repair of Barlow valves were satisfactory irrespective of the approach used to repair the valve. The advantages of MI surgery can be achieved in patients with mitral Barlow disease without concerns over the durability of repair.
Background: Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods: Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results: In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions: Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy.
8 May 2016 in Interactive CardioVascular and Thoracic Surgery
Aortic valve replacement through conventional sternotomy still represents the gold-standard surgical approach for aortic valve disease. However, given the increasing number of patients with comorbidities, strategies that can improve operative results are always sought. Minimally invasive aortic valve surgery, although related to a steep learning curve, might be associated with improved postoperative outcomes. The main aim of this study was to assess whether significant differences exist in terms of operative and early results between a mini-sternotomy and a right mini-thoracotomy approach for isolated aortic valve replacement without sutureless technologies. This is an observational retrospective multicentre study from nine Italian cardiac centres that analyses prospectively collected data of patients who underwent isolated minimally invasive aortic valve replacement between January 2010 and December 2014. Two approaches are considered (mini-sternotomy and mini-thoracotomy) and compared in terms of operative and early outcomes. After interrogation of the centralized database, a total of 1130 patients were retrieved (854 mini-sternotomy and 276 mini-thoracotomy). Patients in the mini-sternotomy group had a higher risk profile. There was no difference in terms of early mortality; cardiopulmonary bypass and cross-clamp time did not differ significantly between the groups; and a significantly higher number of reoperations for bleeding was observed in the right mini-thoracotomy group. Both mini-sternotomy and mini-thoracotomy could be performed safely, with low mortality and postoperative morbidity. The mini-thoracotomy approach was associated with a significantly higher rate of reoperation for bleeding. Uptake among cardiac centres was low. Sutureless technologies could potentially increase surgical volume by simplifying the mini-thoracotomy procedure.