26 July 2023 in IEEE Access
Flexible needle has a sufficient pliability, which could steer clear of obstacles and correct the deviated path to achieve deep target insertions. It has a tendency of replacing rigid needles. An insertion robot for the flexible needle is one of the important parts of the robot-assisted surgery system. This paper proposed a novel insertion robot for an FBG (Fiber Bragg Grating) embedded cannula flexible needle and conducted puncture control experiments. The insertion robot consisted of a configuration adjustment mechanism and an insertion mechanism, which was compact and with a high insertion accuracy. The forward and inverse kinematics of the robot were calculated and the workspace was simulated using MATLAB/SIMULINK. The simulation results show that the robot has a workspace in size of about 200mm by 110mm by 140mm, which completely covers the required position and posture for the prostate insertion. Then a path tracking controller was designed to adjust the insertion path in real-time, realizing the tracking control of the planned path for the cannula flexible needle. Finally, the experiments were carried out to verify the rationality of the robot structure and the effectiveness of the puncture control in an environment with obstacles. The experimental results showed that the insertion average error was 1.3mm, the maximum error was 1.7mm, and the root mean square error was 0.3mm, fulfilling the insertion accuracy requirements of the clinical prostate surgery. This proved the rationality of the structural design and the high precision of the control.
27 November 2024 in IEEE Access
Compared to the traditional flexible needles, cannula flexible needle has advantages in terms of the flexibility and the capability of trajectory correction during insertion. In this paper, the cannula flexible needle is treated as a cantilever beam, and the insertion of the needle into the soft tissue is considered as a quasi-static process. And a mechanical bending model for the large bending of the needle is established based on the large bending theory. Then a bending curve is obtained through the discretization in the mechanical bending model. The relationship between the bending curves and the discretization lengths can be defined as a function family. As the bending is directly controlled by the stylet extension length out of the cannula, the relationship between the different stylet extension lengths and the discretization lengths is formulated through the regression according to the experimental data. Hence, the function family of the bending curves with the variable of the stylet extension length is accomplished. In order to validate the proposed function family, the insertion experiments in the phantom tissues were conducted. The results showed that the mean errors were 0.98 mm and 1.02 mm, the maximum errors were 1.43 mm and 1.53 mm, and the root mean square errors were 0.45mm and 0.51mm, respectively for two cases of the stylet extension lengths, fulfilling the required accuracy for the ordinary clinical surgery, which proves the rationality and accuracy of the proposed method.