Mengyan Tang

Mengyan Tang

Auto-generated profile, based on publicly available information

Mengyan Tang

Shandong Superego Ground Source Heat Pump Technology Co., Ltd., Binzhou 256600, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ZZZhaoYi Zhuang
ZhaoYi Zhuang
JZJin Zhao
Jin Zhao
FMFengfeng Mi
Fengfeng Mi
TZTeng Zhang
Teng Zhang
YHYuguo Hao
Yuguo Hao
SLShangyue Li
Shangyue Li
Heat pump technology can extract low-level heat energy from urban sewage to heat or cool buildings, which can alleviate the two major problems of energy shortage and environmental pollution to a certain extent. This paper introduces the principle of wastewater source heat pump technology and summarizes the current common system forms and their key core technologies. The proposed special heat transfer technology for sewage can effectively solve the problem of blockage and corrosion in the process of sewage heat transfer. Taking the system of an office building in Qingdao as an example, the system design parameter is introduced in detail. The operation monitoring of the heating and air conditioning seasons of this project was completed through a data collection system, and various performance parameters of the system were studied and analyzed. The data was obtained using measured data from one year of system operation. The testing results show that the sewage temperature of the heat pump system in winter is approx. 13.5 °C, the hot water supply temperature is approx. 50 °C, the average COP of the unit is 3.95, and the average COP of the system is 2.96. The calculation results show that the heating energy consumption of the heat pump unit is only 50.81% of that of a traditional heating mode coal-fired boiler and 57.57% of that of an air source heat pump system. In summer, the sewage temperature is approx. 22 °C, the cold-water supply temperature is approx. 5.5 °C, the average COP of the unit is 4.45, and the average COP of the system is 3.25. The cooling energy consumption of the heat pump system is 79.39% of the energy consumption of the traditional chiller and 61.56% of the cooling energy consumption of the air source heat pump system. This shows that the sewage source heat pump system has a remarkable energy-saving effect.

28 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ZZZhaoyi Zhuang
Zhaoyi Zhuang
XYXuebin Yang
Xuebin Yang
KXKun Xie
Kun Xie
MTMengyan Tang
Mengyan Tang
YXYanbiao Xu
Yanbiao Xu
XBXianye Ben
Xianye Ben
Sky radiative cooling is a kind of passive cooling technology that uses the “atmospheric window” to emit the object’s own heat to the low temperature of outer space; this technology has low energy consumption, no pollution, and other useful characteristics, so in recent years it has attracted widespread attention. The cooling effect of the sky radiative cooler is mainly affected by the constantly changing outdoor ambient temperature. In addition, the structure of the radiative cooler itself also means that its radiative cooling power undergoes obvious changes. Here, we utilized COMSOL simulation software to establish a numerical heat transfer model for radiative cooling, aimed at investigating the influencing factors on the sky radiative cooler and methods to enhance the structure of the radiative cooling. This study discusses outdoor ambient wind speed, the inlet flow rate of the cooler, installation angle of the cooler, and different cooler structures. Based on simulation results, it is observed that, for varying wind speeds, when the ambient radiation temperature is higher than the surface temperature of the cooler, a larger ambient wind speed leads to a poorer refrigeration effect. The maximum temperature difference in surface temperature at wind speeds of 0 m/s and 4 m/s is 0.59 °C. When the ambient temperature is lower than the surface temperature of the cooler, a smaller wind speed results in a greater net refrigeration power. The maximum temperature difference in this scenario is 0.32 °C. The net refrigeration power of the radiative cooler increases with an increase in water flow rate. As the water flow rate increases from 0 L/min to 5 L/min, the net refrigeration power increases from 25 W/m2 to 200 W/m2 and gradually stabilizes. Considering the radiative impact of the cooler on the surrounding environment, as the installation angle increases from 0° to 90°, the surface temperature of the cooler first increases and then decreases, reaching its highest temperature of 29.26 °C at 45°. The surface temperature of the cooler varies with the thickness of the air sandwich, increasing from 1 cm to 12 cm, and then decreasing. The lowest temperature of 23.4 °C is achieved at a thickness of 8 cm. The increase in the fin structure on the surface of the radiative cooler leads to a decrease in its refrigeration performance, and the difference between the inlet and outlet temperatures of the radiative cooler with a flat plate structure is always greater than that of the finned plate, and the difference in the average radiance is 23.52 W/m2. Finally, the energy-saving effect of the sky radiative cooling composite system is analyzed. Taking a typical small office building as an example, an energy consumption analysis model is set up, and the energy consumption of the composite system is simulated in four cities with different climates, using EnergyPlus software (version 8.6); the system’s power consumption is the largest in hot and humid climates. Compared with the traditional vapor-compression refrigeration system, the composite system reduces air conditioning power consumption by 25.7%, 32.5%, 37.1%, and 44.8% in Guangzhou, Shanghai, Jinan, and Shenyang, respectively. The main innovations of this paper include analyzing and studying the influence of the tilt angle change of the radiative plate on the refrigeration performance of the cooler and the relationship between the surrounding buildings, adding air sandwiches and ribs to the radiative cooler to analyze the influence of convective heat transfer on the refrigeration effect, which plays a guiding role in the design and research of the sky radiative cooler.

9 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZZZhaoYi Zhuang
ZhaoYi Zhuang
YXYanbiao XU
Yanbiao XU
QWQian Wu
Qian Wu
BLBing Liu
Bing Liu
BLBowen Li
Bowen Li
XYXuebin Yang
Xuebin Yang
As a new passive cooling technology, space radiation cooling has great potential for development because the cooling itself has no energy consumption, and the radiation heat exchanger does not affect the appearance, with low noise and low cost. Several rectangular stainless steel plates coated with RLHY-2 material are used as the transmitter for the field test. The experimental results show that, in the case of no windscreen, the increase of outdoor humidity will reduce the cooling effect, and the greater the humidity, the more pronounced the reduction effect. Significantly when the humidity increases from 78% to 90%, the cooling power of the cooler reduces from 102 to 67 W/m2. The thickness of the cloud layer also affects the cooling effect of the space radiative cooler. Compared with the clear weather, the cooling power of the cooler is reduced by 11.65 W/m2 on average under foggy weather conditions. Compared with the force-1 wind and the force-3 wind, the cooling effect of the cooler is the worst under the condition of the force-2 wind, and the average cooling power is only 49.76 W/m2. In addition, laying polyethylene (PE) film as a windscreen is beneficial to improving the radiative cooling effect, and the difference in surface temperature between the two is up to 3 °C. This research provides a theoretical basis and practical reference for applying radiative cooling technology in different regions and seasons and adjusting and improving its effects.