4 July 2018 in ACTA IMEKO
The project entitled “UNderwater Acoustic Calibration standards for frequencies beLOW 1 kHz” (“UNAC-LOW”), currently active within the European Metrology Programme for Innovation and Research (EMPIR), is presented by describing its objectives and current activities. The project aims at developing the metrological capacity of the European Union (EU) for the calibration of hydrophones and autonomous recording systems for the frequency range between 20 Hz and 1 kHz, for which traceability is presently not fully available. In this way, EU metrological capacities for absolute measurement of underwater sound will be improved, with a direct effect on the implementation of regulation and EU Directives that require underwater acoustic measurements to be traceable. After having completed the initial project tasks regarding the review of existing methods and the design of the experimental setups, comparison measurements between the project partners are currently under way and their results will be validated and presented upon project end after first quarter of 2019. To ensure long-term operation of the calibration capabilities by each partner, a coherent EU metrology strategy for underwater acoustics will be developed as one of the main project outcomes. Current activities include the implementation of the calibration setups developed in earlier stages of the project for both hydrophones and autonomous recorders. The methods that shall be used for hydrophones are the pressure method in a closed chamber and the standing wave tube method. For autonomous recorders, in addition to the above methods, calibrations will be performed using free-field methods in different open-water test sites possessing suitable characteristics for low frequency measurements.
7 May 2024 in Measurement Science and Technology
In this paper, application of a Two-Equations Two-Unknowns (2E-2U) method is described for calibration of hydrophones and projectors below 1 kHz in a laboratory test tank. At low frequencies, amplitude and phase measurements for the calibration of the hydrophones and projectors in the test tank are difficult to perform since echo-free time of the laboratory test tank is not large enough due to transducer initial transients and tank wall boundary reflections. To overcome these difficulties, the 2E-2U method is applied to received (windowed) signals obtained during calibration measurements. Thus, calibration measurements become possible at a frequency down to 250 Hz. These measurements in the test tank are performed for a hydrophone and a developed flextensional projector. First, the received sensitivities for the hydrophone are calculated and validated by comparisons with pressure calibration in a closed chamber. Good agreements are obtained between the two measurement platforms, with a maximum difference of 0.5 dB and uncertainty of 1.3 dB. Then, the transmitting voltage response (TVR) of the flextensional projector is calculated and compared with the calibration data obtained from the method defined in the relevant standards. Good agreements are obtained between the two TVR data with a maximum difference of 1.1 dB and uncertainty of 1.7 dB.
1 October 2016 in The Journal of the Acoustical Society of America
A system to calibrate underwater electro-acoustic hydrophones by primary method, namely, Reciprocity method, in wide frequency range from few kilohertz to megahertz is presented. The aim is to realize primary level “Hydrophone Calibration System” covering from few kilohertz to upper limit of underwater applications with very limited restrictions in one simple system. This system not only covers wide frequency range of underwater applications but also offers low-cost solution to reach enough uncertainty level required for primary calibration according to standards [1]-[3]. The system is based on very high resolution PC oscilloscope of Pico Technology, namely, PicoScope 4262, used for primary data acquizition and digitizing. Primary signal generator and power amplifier, available in market, are integrated into system for purpose. The detailed description is presented and uncertainty budget is discussed.