15 March 2026 in Jurnal Riset Informatika
SNSurya Micrandi Nasution
ITI Kadek Nuary Trisnawan
Missing and incomplete observations in Environmental IoT sensor networks reduce data reliability and disrupt analyses, especially for temperature and humidity time series exhibiting strong diurnal seasonality. This study develops and evaluates a seasonal imputation method to address missing data in IoT-based environmental monitoring, using a workflow of anomaly detection, outlier removal, time-of-day-aware imputation, and performance evaluation under varying missing-rate scenarios. Key challenges include sensor noise, connectivity issues, and intermittent hardware failures, which degrade data integrity and affect trend analysis, forecasting, and anomaly detection. To mitigate these, the method uses hourly and minute-level seasonal patterns after filtering out physically unrealistic values. Experimental results show high accuracy and robustness in reconstructing temperature and humidity data: temperature imputation achieves MAE values of approximately 0.86–0.87°C, and humidity yields MAE values of 3.92–4.01%RH, with no performance drop even at 50% data loss. The imputed series preserves natural diurnal dynamics without introducing distortions, effectively restoring continuity and structural consistency in environmental IoT time series for reliable modeling, feature extraction, and decision support.
5 June 2026 in Clean Energy Science and Technology
One of the hardest parts of running a power system is economic dispatch (ED), which means finding the cheapest way to meet demand and operational limits. To alleviate these limitations, this study presents a hybrid methodology known as Vectorized Lambda Iteration Method–Clone-Based Optimization with Lévy flight (VLIM-CBO-LF). The contribution comprises the synchronized amalgamation of three complementary strategies. The VLIM-CBO-LF improves the accuracy of dispatch calculations, clone-based optimization improves local search by using adaptive cloning, selection, and Lévy flight improves global exploration by letting movements happen over long distances from time to time. The suggested method was tested on a 42-unit economic dispatch system over a 24-h period, running it 30 times to make sure it worked each time. The results show that VLIM-CBO-LF has the lowest average daily fuel cost of IDR 3.9096 × 1010. This is better than the artificial bee colony, particle swarm optimization, grey wolf optimization, and whale optimization algorithm. The cost goes down from IDR 1.050 × 10⁹ to 3.666 × 10⁹ per day, but the performance stays the same, with a standard deviation of 6.50 × 10⁷ IDR. The ANOVA test (F = 19.004, p = 1.820 × 10⁻⁷) and the Friedman test (χ2 = 60, p = 9.358 × 10⁻14) both show that the results are statistically significant. The Wilcoxon signed-rank test (W⁺ = 0) shows that the results are strictly better than all other benchmark methods. Future research may investigate the applicability of the VLIM-CBO-LF model to more complex electrical market mechanisms.