Fredrik Pernbro

Fredrik Pernbro

Auto-generated profile, based on publicly available information

Fredrik Pernbro

Department of Paediatric Anaesthesiology and Intensive Care, University of Gothenburg, Institute of Clinical Sciences, Gothenburg, Sweden

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2024 in Cardiology in the Young
Verified
Journal Article
Open access
PDF file
FPFredrik Pernbro
Fredrik Pernbro
HWHåkan Wåhlander
Håkan Wåhlander
BRBirgitta Romlin
Birgitta Romlin
Background: Haemodynamic instability is common after surgical repair of CHDs in infants and children. Monitoring cardiac output in addition to traditional circulation parameters could improve the postoperative care of these patients. Echocardiography and transpulmonary thermodilution are the two most common methods for measuring cardiac output in infants.Objectives: To compare the results of cardiac output measurements using echocardiography and a transpulmonary thermodilution setup after paediatric cardiac surgery.Methods: Forty children, scheduled for elective repair of a ventricular septal defect or of an atrio-ventricular septal defect using cardiopulmonary bypass, were enrolled in this prospective, observational study. Cardiac output was simultaneously measured using echocardiography and a commercially available transpulmonary thermodilution method (PiCCO™) at 18 h after the end of surgery.Results: At 18 h after surgery, PiCCO™ gave a mean of 3.0% higher cardiac output than echocardiography. This difference was not statistically significant. 95% of the observations fell within –50.0 to 82.6%.Conclusion: The methods were found to have a good agreement on average, with no statistically significant difference between them. However, the spread of the results was large. It is questionable whether the methods can be used interchangeably in clinical practice.

8 February 2021 in Cardiology in the Young
Verified
Journal Article
Open access
PDF file
FSFredrik Söderlund
Fredrik Söderlund
HWHåkan Wåhlander
Håkan Wåhlander
EHEmma C. Hansson
Emma C. Hansson
BRBirgitta S. Romlin
Birgitta S. Romlin
Objective: The objectives of the present study were to determine whether there was any association between the grade of heart failure, as expressed by preoperative levels of brain natriuretic peptide and Ross score, and the preoperative coagulation status in patients with non-restrictive ventricular shunts and determine whether there were any postoperative disturbances of the coagulation system in these patients, as measured by thromboelastometry and standard laboratory analyses of coagulation.Design: Perioperative coagulation was analysed with laboratory-based coagulation tests and thromboelastometry before, 8 hours after, and 18 hours after cardiac surgery. In addition, brain natriuretic peptide was analysed before and 18 hours after surgery.Patients: 40 children less than 12 months old with non-restrictive congenital ventricular or atrio-ventricular shunts scheduled for elective repair of their heart defects.Results: All coagulation parameters measured were within normal ranges preoperatively. There was a significant correlation between brain natriuretic peptide and plasma fibrinogen concentration preoperatively. There was no statistically significant correlation between brain natriuretic peptide and INTEM-MCF, FIBTEM-MCF, plasma fibrinogen, activated partial thromboplastin time, prothrombin time, or platelet count at any other time point, either preoperatively or postoperatively. Postoperatively, fibrinogen plasma concentration and FIBTEM-MCF decreased significantly at 8 hours, followed by a large increase at 18 hours to higher levels than preoperatively.Conclusions: There was no evidence of children with non-restrictive shunts having coagulation abnormalities before cardiac surgery. Brain natriuretic peptide levels or Ross score did not correlate with coagulation parameters in any clinically significant way.

29 February 2024 in Progress in Pediatric Cardiology
Verified
Journal Article
Closed access
FPFredrik Pernbro
Fredrik Pernbro
SSSukhi Singh
Sukhi Singh
HWHåkan Wåhlander
Håkan Wåhlander
EHEmma C. Hansson
Emma C. Hansson
BRBirgitta Romlin
Birgitta Romlin

4 September 2024 in Interdisciplinary CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
AHAnders Hjärpe
Anders Hjärpe
AJAnders Jeppsson
Anders Jeppsson
LLLukas Lannemyr
Lukas Lannemyr
FPFredrik Pernbro
Fredrik Pernbro
CHCamilla Hesse
Camilla Hesse
BRBirgitta Romlin
Birgitta Romlin
Extracorporeal circulation induces pronounced effects on haemostasis and rheology. To study these, an ex vivo simulation model is an attractive alternative but often requires large amounts of blood. We sought to create a miniaturized roller pump circuit requiring minimal amounts of blood and to test if the circuit could be used to compare coagulation, platelet function and blood rheology between a dextran-based and a crystalloid-based priming solution. A miniaturized roller pump circuit requiring only 27 ml of blood was created. Blood samples from 8 cardiac surgery patients were mixed with either a dextran-based or a crystalloid-based solution and circulated for 60 min. Coagulation was assessed by rotational thromboelastometry, and platelet function by impedance aggregometry and flow cytometry, before and at 5 and 60 min of circulation. A time-dependent impairment of coagulation was observed in both groups. Maximum clot firmness was lower with dextran-based than with crystalloid-based priming at 5 min (HEPTEM 37 ± 4 vs 43 ± 4 mm, P < 0.001; EXTEM 37 ± 4 vs 43 ± 4 mm, P < 0.001; FIBTEM 3 ± 2 vs 9 ± 2 mm, P < 0.001) and at 60 min (HEPTEM 29 ± 9 vs 38 ± 5 mm, P < 0.001; EXTEM 30 ± 7 vs 39 ± 5 mm, P < 0.001; FIBTEM 3 ± 2 vs 8 ± 3 mm, P = 0.002). The EXTEM clotting time was longer with dextran-based solution at 5 (109 ± 19 vs 63 ± 7 sec, P < 0.001) and at 60 min (176 ± 72 vs 73 ± 7 sec, P = 0.004). The novel miniaturized roller pump circuit can be used to mimic extracorporeal circulation for selected research questions. Dextran-based priming caused a significant impairment in haemostasis compared with a standard crystalloid solution.