Bernhard H. Weigl

Bernhard H. Weigl

Auto-generated profile, based on publicly available information

Bernhard H. Weigl

Program for Appropriate Technology in Health (PATH), Seattle, WA, USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
BWBernhard Weigl
Bernhard Weigl
GDGonzalo Domingo
Gonzalo Domingo
PLPaul LaBarre
Paul LaBarre
JGJay Gerlach
Jay Gerlach
In many health care settings, it is uneconomical, impractical, or unaffordable to maintain and access a fully equipped diagnostics laboratory. Examples include home health care, developing-country health care, and emergency situations in which first responders are dealing with pandemics or biowarfare agent release. In those settings, fully disposable diagnostic devices that require no instrument support, reagent, or significant training are well suited. Although the only such technology to have found widespread adoption so far is the immunochromatographic rapid assay strip test, microfluidics holds promise to expand the range of assay technologies that can be performed in formats similar to that of a strip test. In this paper, we review progress toward development of disposable, low-cost, easy-to-use microfluidics-based diagnostics that require no instrument at all. We also present examples of microfluidic functional elements—including mixers, separators, and detectors—as well as complete microfluidic devices that function entirely without any moving parts and external power sources.

28 June 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JBJoshua D. Bishop
Joshua D. Bishop
HHHelen V. Hsieh
Helen V. Hsieh
DGDavid J. Gasperino
David J. Gasperino
BWBernhard H. Weigl
Bernhard H. Weigl
This critical review organizes and evaluates state-of-the-art approaches to LFA sensitivity enhancement from a system-level perspective.

28 May 2017 in Diagnostics
Verified
Journal Article
Open access
PDF file
HHHelen Hsieh
Helen Hsieh
JDJeffrey Dantzler
Jeffrey Dantzler
BWBernhard H. Weigl
Bernhard H. Weigl
Immunochromatographic or lateral flow assays (LFAs) are inexpensive, easy to use, point-of-care medical diagnostic tests that are found in arenas ranging from a doctor’s office in Manhattan to a rural medical clinic in low resource settings. The simplicity in the LFA itself belies the complex task of optimization required to make the test sensitive, rapid and easy to use. Currently, the manufacturers develop LFAs by empirical optimization of material components (e.g., analytical membranes, conjugate pads and sample pads), biological reagents (e.g., antibodies, blocking reagents and buffers) and the design of delivery geometry. In this paper, we will review conventional optimization and then focus on the latter and outline analytical tools, such as dynamic light scattering and optical biosensors, as well as methods, such as microfluidic flow design and mechanistic models. We are applying these tools to find non-obvious optima of lateral flow assays for improved sensitivity, specificity and manufacturing robustness.

2 February 2024 in Clinical Infectious Diseases
Verified
Journal Article
Open access
PDF file
ASAmy Steadman
Amy Steadman
AAAlfred Andama
Alfred Andama
ABAlexey Ball
Alexey Ball
JMJob Mukwatamundu
Job Mukwatamundu
KKKhushboo Khimani
Khushboo Khimani
ACAdithya Cattamanchi
Adithya Cattamanchi
Background: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2–99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. Conclusions: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab–based TB diagnostics.

1 June 2012 in Point of Care: The Journal of Near-Patient Testing & Technology
Verified
Journal Article
Closed access
BWBernhard H. PhD Weigl
Bernhard H. PhD Weigl
CGCharlotte A. DrPH Gaydos
Charlotte A. DrPH Gaydos
GKGerald MD Kost
Gerald MD Kost
FBFred R. Jr PhD Beyette
Fred R. Jr PhD Beyette
SSStephanie Bsc Sabourin
Stephanie Bsc Sabourin
JHJohn PhD Haller
John PhD Haller
Most entrepreneurial ventures fail long before the core technology can be brought to the marketplace because of disconnects in performance and usability measures such as accuracy, cost, complexity, assay stability, and time requirements between technology developers’ specifications and needs of the end-users. By going through a clinical needs assessment (CNA) process, developers will gain vital information and a clear focus that will help minimize the risks associated with the development of new technologies available for use within the health care system. This article summarizes best practices of the principal investigators of the National Institute of Biomedical Imaging and Bioengineering point-of-care (POC) centers within the National Institute of Biomedical Imaging and Bioengineering POC Technologies Research Network. Clinical needs assessments are particularly important for product development areas that do not sufficiently benefit from traditional market research, such as grant-funded research and development, new product lines using cutting-edge technologies developed in start-up companies, and products developed through product development partnerships for low-resource settings. The objectives of this article were to (1) highlight the importance of CNAs for development of POC devices, (2) discuss methods applied by POC Technologies Research Network for assessing clinical needs, and (3) provide a road map for future CNAs.

9 March 2013 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
JSJered Singleton
Jered Singleton
CZChris Zentner
Chris Zentner
JBJosh Buser
Josh Buser
PYPaul Yager
Paul Yager
PLPaul LaBarre
Paul LaBarre
BWBernhard H. Weigl
Bernhard H. Weigl
Many infectious diseases, as well as some cancers, that affect global health are most accurately diagnosed through nucleic acid amplification and detection. There is a great need to simplify nucleic acid-based assay systems for use in global health in low-resource settings as well as in settings that do not have convenient access to laboratory staff and equipment such as doctors’ offices and home care settings. In developing countries, unreliable electric power, inadequate supply chains, and lack of maintenance for complex diagnostic instruments are all common infrastructure shortfalls. Many elements of instrument-free, disposable, nucleic acid amplification assays have been demonstrated in recent years. However, the problem of instrument-free,1 low-cost, temperature-controlled chemical heating remains unsolved. In this paper we present the current status and results of work towards developing disposable, low-cost, temperature-controlled heaters designed to support isothermal nucleic acid amplification assays that are integrated with a two-dimensional paper network. Our approach utilizes the heat generated through exothermic chemical reactions and controls the heat through use of engineered phase change materials to enable sustained temperatures required for nucleic acid amplification. By selecting appropriate exothermic and phase change materials, temperatures can be controlled over a wide range, suitable for various isothermal amplification methods, and maintained for over an hour at an accuracy of +/- 1°C.