Takayuki Shima

Takayuki Shima

Auto-generated profile, based on publicly available information

Takayuki Shima

National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2002 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TKT. Kikukawa
T. Kikukawa
TNT. Nakano
T. Nakano
TST. Shima
T. Shima
JTJ. Tominaga
J. Tominaga
Huge signal enhancement was observed by a super-resolution near-field structure disk with a platinum-oxide layer. The carrier-to-noise ratio of 200-nm-mark trains reached 46.1 dB, and 42.3 dB was obtained even at 150-nm-mark trains. The sizes of the marks were one-fifth to one-seventh of the laser spot diameter of the readout system. The cross section of the mark trains was also observed by transmission electron microscopy. It was confirmed that 200-nm-size bubble pits were rigidly formed in good separation and ∼20-nm-platinum particles precipitated inside the bubble. The computer-simulation based on the model supported the huge signal enhancement.

1 July 2008 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
JTJuniji Tominaga
Juniji Tominaga
PFPaul Fons
Paul Fons
AKAlexander Kolobov
Alexander Kolobov
TSTakayuki Shima
Takayuki Shima
TCTow Chong Chong
Tow Chong Chong
LSLuping Shi
Luping Shi

29 January 2004 in Nanotechnology
Verified
Journal Article
Closed access
JTJunji Tominaga
Junji Tominaga
TSTakayuki Shima
Takayuki Shima
MKMasashi Kuwahara
Masashi Kuwahara
TFToshio Fukaya
Toshio Fukaya
AKAlexander Kolobov
Alexander Kolobov
TNTakashi Nakano
Takashi Nakano

1 September 2003 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JKJooho Kim
Jooho Kim
IHInoh Hwang
Inoh Hwang
DYDuseop Yoon
Duseop Yoon
IPInsik Park
Insik Park
DSDongho Shin
Dongho Shin
JTJunji Tominaga
Junji Tominaga
The recording and retrieval of signals below 100 nm mark length were attempted with elliptical bubble-type super-resolution technology with platinum oxide (PtOx) and ductile AgInSbTe layers, using the same optical system as that of a digital versatile disk (a 635 nm wavelength red laser system). The carrier-to-noise ratio (CNR) of over 47 dB for 100 nm mark length signals (over 43 dB for 80 nm mark length signals) was obtained, which can be considered as a commercially acceptable level of CNR. The recording mechanism of the sample disk was shown through the transmission electron microscopy cross-section image observation to be by rigid elliptical bubble formation at the PtOx layer located between the AgInSbTe layers. The results of this report represent the potential for a much higher-density storage using the red laser system and a subterabyte optical storage using the blue laser system.

1 March 2009 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
JTJunji Tominaga
Junji Tominaga
TSTakayuku Shima
Takayuku Shima
PFPaul Fons
Paul Fons
RSRobert Simpson
Robert Simpson
MKMasashi Kuwahara
Masashi Kuwahara
AKAlexander Kolobov
Alexander Kolobov

11 July 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SGSubash C. B. Gopinath
Subash C. B. Gopinath
KAKoichi Awazu
Koichi Awazu
MFMakoto Fujimaki
Makoto Fujimaki
KSKazufumi Shimizu
Kazufumi Shimizu
TSTakayuki Shima
Takayuki Shima
Gold nanoparticles were conjugated to an antibody (immuno-AuNP) against A/Udorn/307/1972 (H3N2) influenza virus to detect viruses on a sensing plate designed for an evanescent field-coupled waveguide-mode sensor. Experiments were conducted using human influenza A/H3N2 strains, and immuno-AuNP could detect 8×105 PFU/ml (40 pg/µl) intact A/Udorn/307/1972 and 120 pg/µl A/Brisbane/10/2007. Furthermore, increased signal magnitude was achieved in the presence of non-ionic detergent, as the virtual detection level was increased to 8×104 PFU/ml A/Udorn/307/1972. Immuno-AuNPs were then complexed with viruses to permit direct observation, and they formed a ring of confined nanodots on the membrane of both intact and detergent-treated viruses as directly visualized by scanning electron microscopy. With this complex the detection limit was improved further to 8×103 PFU/ml on anti-rabbit IgG immobilized sensing plate. These strategies introduce methods for observing trapped intact viruses on the sensing plates generated for optical systems.