Endothelial barrier function is known to be regulated by a number of molecular mechanisms; however, the role of biomechanical signals associated with blood flow is comparatively less explored. Biomimetic microfluidic models comprised of vessel analogues that are lined with endothelial cells (ECs) have been developed to help answer several fundamental questions in endothelial mechanobiology. However, previously described microfluidic models have been primarily restricted to single straight or two parallel vessel analogues, which do not model the bifurcating vessel networks typically present in physiology. Therefore, the effects of hemodynamic stresses that arise due to bifurcating vessel geometries on ECs are not well understood. Here, we introduce and characterize a microfluidic model that mimics both the flow conditions and the endothelial/extracellular matrix (ECM) architecture of bifurcating blood vessels to systematically monitor changes in endothelial permeability mediated by the local flow dynamics at specific locations along the bifurcating vessel structure. We show that bifurcated fluid flow (BFF) that arises only at the base of a vessel bifurcation and is characterized by stagnation pressure of ∼38 dyn cm−2 and approximately zero shear stress induces significant decrease in EC permeability compared to the static control condition in a nitric oxide (NO)-dependent manner. Similarly, intravascular laminar shear stress (LSS) (3 dyn cm−2) oriented tangential to ECs located downstream of the vessel bifurcation also causes a significant decrease in permeability compared to the static control condition via the NO pathway. In contrast, co-application of transvascular flow (TVF) (∼1 μm s−1) with BFF and LSS rescues vessel permeability to the level of the static control condition, which suggests that TVF has a competing role against the stabilization effects of BFF and LSS. These findings introduce BFF at the base of vessel bifurcations as an important regulator of vessel permeability and suggest a mechanism by which local flow dynamics control vascular function in vivo.
Previous in vitro studies have reported on the use of direct current electric fields (DC-EFs) to regulate vascular endothelial permeability, which is important for tissue regeneration and wound healing. However, these studies have primarily used static 2D culture models that lack the fluid mechanical forces associated with blood flow experienced by endothelial cells (ECs) in vivo. Hence, the effect of DC-EF on ECs under physiologically relevant fluid forces is yet to be systematically evaluated. Using a 3D microfluidic model of a bifurcating vessel, we report the role of DC-EF on regulating endothelial permeability when co-applied with physiologically relevant fluid forces that arise at the vessel bifurcation. The application of a 70 V m−1 DC-EF simultaneously with 1 μL min−1 low perfusion rate (generating 3.8 dyn cm−2 stagnation pressure at the bifurcation point and 0.3 dyn cm−2 laminar shear stress in the branched vessel) increased the endothelial permeability 7-fold compared to the static control condition (i.e., without flow and DC-EF). When the perfusion rate was increased to 10 μL min−1 (generating 38 dyn cm−2 stagnation pressure at the bifurcation point and 3 dyn cm−2 laminar shear stress in the branched vessel) while maintaining the same electrical stimulation, a 4-fold increase in endothelial permeability compared to the static control was observed. The lower increase in endothelial permeability for the higher fluid forces but the same DC-EF suggests a competing role between fluid forces and the applied DC-EF. Moreover, the observed increase in endothelial permeability due to combined DC-EF and flow was transient and dependent on the Akt signalling pathway. Collectively, these findings provide significant new insights into how the endothelium serves as an electro-mechanical interface for regulating vessel permeability.
Selective permeation of water vapor over liquid phase water through hydrophobic conduits finds broad use in separation processes, including desalination and membrane distillation. The tangential momentum accommodation coefficient (TMAC), a fundamental parameter that dictates momentum changes to a molecule colliding with a wall remains unknown for water vapor at room temperature and pressure conditions. Here, a nanofluidic platform with tunable hydrophobic regions that selectively barricaded flow of liquid water was patterned within glass nanochannels. The surface functionalization with an alkyltrichlorosilane led to either a fluoride or a methyl terminal group generating partially hydrophobic regions along the length of the nanochannels. Differential osmotic pressure solutions on either side of the hydrophobic region cause an isothermal evaporation–condensation process, which drives net water vapor transport from higher to lower vapor pressure solution, similar to osmotic distillation. Water vapor transport under such conditions for the 80 nm deep nanochannels was in the transitional regime with the Knudsen number ∼O(1). The TMAC was estimated experimentally to be of the order of 10−4–10−3 for both the hydrophobic coatings leading to a near-elastic collision of H2O molecules with the nanochannel walls. Use of the low TMAC surfaces was evaluated in two proof-of-concept technology demonstrations: (1) osmotic distillation using hyper-saline (brine) 3 M Utica shale flowback water as both the feed and draw and (2) separation of trace amounts of toluene and chloroform from water at high flux and selectivity. The results reported here likely provide new insights in designing hydrophilic–hydrophobic junctions for nanoscale liquid/vapor fluid transport with enhanced flux and selectivity.
A hybrid microfluidic–nanofluidic device was evaluated for the transport of a variety of ions with the purpose of enhancing the understanding of surface charge regulation for electrokinetic transport within silica nanochannels.