1 November 2021 in RadioGraphics
Verified
Journal Article
Closed access
YNYasunori Nagayama
Yasunori Nagayama
DSDaisuke Sakabe
Daisuke Sakabe
MGMakoto Goto
Makoto Goto
TETakafumi Emoto
Takafumi Emoto
SOSeitaro Oda
Seitaro Oda
THToshinori Hirai
Toshinori Hirai
By incorporating convolutional neural networks into the image reconstruction process, deep learning–based reconstruction reduces noise while preserving spatial resolution and preferable noise textu... Optimizing the CT acquisition parameters to obtain diagnostic image quality at the lowest possible radiation dose is crucial in the radiosensitive pediatric population. The image quality of low-dos...

28 March 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
YNYasunori Nagayama
Yasunori Nagayama
KIKoya Iwashita
Koya Iwashita
NMNatsuki Maruyama
Natsuki Maruyama
HUHiroyuki Uetani
Hiroyuki Uetani
MGMakoto Goto
Makoto Goto
THToshinori Hirai
Toshinori Hirai

1 November 2019 in Academic Radiology
Verified
Journal Article
Closed access
HIHitoshi Iizuka
Hitoshi Iizuka
YYYasuhiro Yokota
Yasuhiro Yokota
MKMasafumi Kidoh
Masafumi Kidoh
SOSeitaro Oda
Seitaro Oda
OIOsamu Ikeda
Osamu Ikeda
DUDaisuke Utsunomiya
Daisuke Utsunomiya

26 December 2019 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
YNYasunori Nagayama
Yasunori Nagayama
STS. Tanoue
S. Tanoue
SOS. Oda
S. Oda
DSD. Sakabe
D. Sakabe
TET. Emoto
T. Emoto
YYY. Yamashita
Y. Yamashita
BACKGROUND AND PURPOSE: Deep brain stimulation electrodes induce massive artifacts on CT images, deteriorating the diagnostic value of examinations. We aimed to investigate the usefulness and potential limitations of a single-energy metal artifact reduction algorithm in head CT performed in patients with implanted deep brain stimulation devices. MATERIALS AND METHODS: Thirty-four patients with deep brain stimulation (bilateral, n = 28) who underwent head CT on a 320–detector row scanner and whose images were reconstructed with and without single-energy metal artifact reduction at the examinations were retrospectively included. The severity of artifacts around electrodes was assessed objectively using SDs and an artifact index. Two radiologists subjectively evaluated the severity of artifacts from electrodes, the visibility of electrode localization and surrounding structures, and overall diagnostic confidence on 4-point scales. Background image quality (GM-WM contrast and image noise) was subjectively and objectively assessed. The presence and location of artifacts newly produced by single-energy metal artifact reduction were analyzed. RESULTS: Single-energy metal artifact reduction provided lower objective and subjective metal artifacts and improved visualization of electrode localization and surrounding structures and diagnostic confidence compared with non-single-energy metal artifact reduction images, with statistical significance (all, P < .01). No significant differences were observed in GM-WM contrast and image noise (all, P ≥ .11). The new artifacts from single-energy metal artifact reduction were prominently observed in patients with bilateral deep brain stimulation at high convexity, possibly induced by deep brain stimulation leads placed under the parietal scalp. CONCLUSIONS: Single-energy metal artifact reduction substantially reduces the metal artifacts from deep brain stimulation electrodes and improves the visibility of intracranial structures without affecting background image quality. However, non-single-energy metal artifact reduction images should be simultaneously reviewed to accurately assess the entire intracranial area, particularly in patients with bilateral deep brain stimulation.

12 March 2021 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
MYMorikatsu Yoshida
Morikatsu Yoshida
TNTakeshi Nakaura
Takeshi Nakaura
SOSeitaro Oda
Seitaro Oda
MKMasafumi Kidoh
Masafumi Kidoh
YNYasunori Nagayama
Yasunori Nagayama
YFYoshinori Funama
Yoshinori Funama
Background: The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. Purpose: To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. Material and Methods: After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. Results: On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. Conclusion: The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.

6 April 2025 in Radiography
Verified
Journal Article
Closed access
JMJ. Mochizuki
J. Mochizuki
KEK. Endo
K. Endo
SOS. Ohira
S. Ohira
TKT. Kojima
T. Kojima
TNT. Niwa
T. Niwa
DSD. Sakabe
D. Sakabe