A. Mohan

A. Mohan

Auto-generated profile, based on publicly available information

A. Mohan

Department of Civil Engineering, Easwari Engineering College, Chennai, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
AMA. Mohan
A. Mohan
SKSaravana Karthika
Saravana Karthika
JAJ. Ajith
J. Ajith
LDLenin Dhal
Lenin Dhal
MTM. Tholkapiyan
M. Tholkapiyan

1 August 2021 in Environmental Technology & Innovation
Verified
Journal Article
Closed access
D.S. VijayanD.S. Vijayan
D.S. Vijayan
AMA. Mohan
A. Mohan
JRJ. Revathy
J. Revathy
Parthiban DevarajanParthiban Devarajan
Parthiban Devarajan
RVR. Varatharajan
R. Varatharajan

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
D.S. VijayanD.S. Vijayan
D.S. Vijayan
AMA. Mohan
A. Mohan
JDJ. Jebasingh Daniel
J. Jebasingh Daniel
VGV. Gokulnath
V. Gokulnath
BSB. Saravanan
B. Saravanan
PKP. Dinesh Kumar
P. Dinesh Kumar
An ecofriendly fiber reinforced polymer (FRP) had been used in the last decade to enhance the short concrete column’s strength and deformation capacity. This study involves the wrapping of FRP sheets with a thickness of 3 mm and 5 mm on a short column, and then the compressive strength is determined. The rectangular columns of size 150 mm × 300 mm are used for this study, and cast under the grades of M20 and M40 are wrapped with GFRP sheets at the thickness of 3 mm and 5 mm. These results are clarified at a specific thickness of the FRP‐wrapped columns. It provides a maximum axial compressive strength, and Young’s modulus gets enhanced rigorously when it is to be compared to the normal concrete. This thesis deals with experimental studies of different parameters associated with wrapped glass fiber reinforced polymer (GFRP). In M20 grade, when the 3 mm wrapped specimen and the 5 mm wrapped specimen are compared, the specimen wrapped with 5 mm increases 5.182% more than the specimen wrapped with 3 mm. In M40 grade, when the 0 mm, 3 mm, and 5 mm wrapped specimens are compared, the specimen wrapped with 5 mm increases 2.47% more than the specimen wrapped with 0 mm. The 5 mm wrapping attains the maximum strength.

22 November 2019 in International Journal of Engineering and Advanced Technology
Verified
Journal Article
Closed access
MJM. Jothilakshmi
M. Jothilakshmi
LCL. Chandrakanthamma
L. Chandrakanthamma
KCK.S.DHaya Chandhran
K.S.DHaya Chandhran
AMA. Mohan
A. Mohan
The water resources management affords many solutions to manage water more holistically and optimally. In essence, they are a call to stop fragmentary approaches to water management and high-handed development decisions made for the benefit of a single user group of action.The Integrated Water Basin Management and its components are used to find a suitable flood mititgation measure. The study area is Orathur of Kancheepuram district. The data that are used in this work is been taken for the consecutive 20 years and it has been analysed. With the overall data the GIS mapping is done using ArcGIS software to locate the area precisely. Its tributaries and origin from Manimangalam tributary is located clearly to estimate the inflow and outflow of the water and the demand for water at the particular region is found and then analysed for the planning of water management and flood control.

1 January 2022 in Journal of Environmental and Public Health
Verified
Journal Article
Open access
PDF file
D.S. VijayanD.S. Vijayan
D.S. Vijayan
AMA. Mohan
A. Mohan
CNC. Nivetha
C. Nivetha
VSVidhyalakshmi Sivakumar
Vidhyalakshmi Sivakumar
Parthiban DevarajanParthiban Devarajan
Parthiban Devarajan
ASArvindan Sivasuriyan
Arvindan Sivasuriyan
The treatment of pharmaceutical effluent using an appropriate technology has become so important. Anaerobic packed bed reactor is an efficient method for pharmaceutical effluent treatment because of the high organic content present in it. In this study, a heavy‐polluted pharma effluent is treated using an anaerobic packed bed reactor. The performance of the anaerobic reactor was identified with respect to chemical oxygen demand (COD) removal, methane yield, and gas production. The results showed that COD was reduced from 73% to 60% for an organic loading rate (OLR) of 0.6036–1.7487 kg COD m−3·d−1. As the OLR increases, the removal efficiency of COD decreases gradually to around 52% for an OLR of 2.34 kg COD m−3·d−1.

24 February 2026 in Structural Concrete
Verified
Journal Article
Closed access
KSKotteeswaran Santhanam
Kotteeswaran Santhanam
CGChristo George
Christo George
APAlok Pandey
Alok Pandey
SOSomdutta
Somdutta
SKS. Karthik
S. Karthik
George Uwadiegwu AlanemeGeorge Uwadiegwu Alaneme
George Uwadiegwu Alaneme