Gul Ozyilmaz

Gul Ozyilmaz

Auto-generated profile, based on publicly available information

Gul Ozyilmaz

Mustafa Kemal Universitesi

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2022 in Food Chemistry
Verified
Journal Article
Closed access
GOGul Ozyilmaz
Gul Ozyilmaz
EGEcenur Gunay
Ecenur Gunay

1 December 2012 in Food Chemistry
Verified
Journal Article
Closed access
GOGul Ozyilmaz
Gul Ozyilmaz
EYEsra Yağız
Esra Yağız

1 June 2013 in Progress in Organic Coatings
Verified
Journal Article
Closed access
AOA. Tuncay Ozyilmaz
A. Tuncay Ozyilmaz
AAAbdurrahman Akdag
Abdurrahman Akdag
IKI. Hakki Karahan
I. Hakki Karahan
GOGul Ozyilmaz
Gul Ozyilmaz

1 August 2007 in Progress in Organic Coatings
Verified
Journal Article
Closed access
AÖA. Tuncay Özyılmaz
A. Tuncay Özyılmaz
NÇNureddin Çolak
Nureddin Çolak
GOGul Ozyilmaz
Gul Ozyilmaz
MSM. Kemal Sangün
M. Kemal Sangün

4 April 2022 in Natural and Engineering Sciences
Verified
Journal Article
Open access
PDF file
EYEsra Yağiz
Esra Yağiz
GOGül Ozyi̇lMaz
Gül Ozyi̇lMaz
AOAli Tuncay Ozyi̇lMaz
Ali Tuncay Ozyi̇lMaz
In this study, construction of amperometric glucose biosensor was carried out by immobilizing of glucose oxidase (GOD) on carbon paste electrode (CPE) which was coated with polyaniline (PANI) by cyclic voltammetry technique. Since the current values to be measured depending on the glucose concentration will be affected by the graphite:mineral oil composition of the electrode, this parametres were optimized by response surface methodology (RSM). For this, State Ease Design Expert 8.0.7.1. (Serial Number: 0021-6578) software software was used applying Optimal Design. By using data obtained, Design Expert software suggested quadratic model to predict current values in terms of working parameters. In study, experimentally measured current values and predicted values by model were considerably found compatable and suitability of model was supported by ANOVA test.

9 March 2011 in Applied Biochemistry and Microbiology
Verified
Journal Article
Closed access
PDF file
GOG. Ozyilmaz
G. Ozyilmaz
AOA. T. Ozyilmaz
A. T. Ozyilmaz
FCF. Can
F. Can
Amperometric glucose biosensors have been developed based on entrapment on platinum (Pt) electrode using cyclic voltammetry technique in glucose oxidase (GOD) and pyrrole containing p-toluenesulfonic...