Jung-Young Son

Jung-Young Son

Auto-generated profile, based on publicly available information

Jung-Young Son

School of Computer and Communication Engineering, Daegu University, Kyungsan, Kyungbuk 712-714, South Korea

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2008 in Sensors
Verified
Journal Article
Open access
PDF file
YVYuriy Vashpanov
Yuriy Vashpanov
JSJung Young Son
Jung Young Son
KKKae Dal Kwack
Kae Dal Kwack
Changes in electric parameters of a mesoporous silicon treated by a plasma chemical etching with fluorine and hydrogen ions, under the adsorption of NEPO (Nematodetransmitted Polyhedral) plant viruses such as TORSV (Tomato Ringspot Virus), GFLV (Grapevine Fan Leaf Virus) and protein macromolecule from TORSV particles are described. The current response to the applied voltage is measured for each virus particle to investigate the material parameters which are sensitive to the adsorbed particles. The peculiar behaviors of the response are modeled by the current-voltage relationship in a MOSFET. This model explains the behavior well and the double gate model of the MOSFET informs that the mesoporous silicon is a highly sensitive means of detecting the viruses in the size range less than 50 nm.

27 June 2011 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
JSJung-Young Son
Jung-Young Son
Seokwon YeomSeokwon Yeom
Seokwon Yeom
JCJoo-Hwan Chun
Joo-Hwan Chun
VGVladmir P. Guschin
Vladmir P. Guschin
DLDong-Su Lee
Dong-Su Lee
The equivalent ray geometry of two horizontally aligned detectors at the focal plane of the main antenna in a millimeter wave imaging system is analyzed to reveal the reason why the images from the detectors are fused as an image with a depth sense. Scanning the main antenna in both horizontal and vertical directions makes each detector perform as a camera, and the two detectors can work like a stereo camera in the millimeter wave range. However, the stereo camera geometry is different from that of the stereo camera used in the visual spectral range because the detectors’ viewing directions are diverging to each other and they are a certain distance apart. The depth sense is mainly induced by the distance between detectors. The images obtained from the detectors in the millimeter imaging system are perceived with a good depth sense. The disparities responsible for the depth sense are identified in the images.