Levent Yilik

Levent Yilik

Auto-generated profile, based on publicly available information

Levent Yilik

Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital, İzmir, Türkiye

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2012 in The Thoracic and Cardiovascular Surgeon
Verified
Journal Article
Closed access
LYLevent Yilik
Levent Yilik
OGOrhan Gokalp
Orhan Gokalp
SBSerdar Bayrak
Serdar Bayrak
TGTevfik Gunes
Tevfik Gunes
NKNihan Karakas
Nihan Karakas
IYIsmail Yurekli
Ismail Yurekli
Background Management of thoracic aorta aneurysms—especially the ones including aortic arch—is highly complicated. Isolated or nonisolated aortic arch aneurysms can be repaired by hybrid procedure especially in patients with comorbidities as well as by conventional open methods. Methods Eleven patients who underwent total arch debranching and endovascular stent implantation on antegrade route in the same session between November 2006 and October 2009 were retrospectively evaluated using clinical and perioperative criteria. Results The mean age was 65 ± 6.2 and nine of the patients were male. Primary technical success rate was 100%. Mortality, stroke, or transient paraplegia/paraparesia was not seen during in-hospital follow-up. Average follow-up period was 36 ± 13 months and no late-term aortic pathology was seen. In only one of the patients, endovascular reintervention was required for type 1B endoleak. No mortality or neurological pathology was seen in long-term postoperative follow-up. Conclusion Hybrid procedures could be performed safely with lower complication and higher success rates in the same session via antegrade route and zone 0 graft deployment for high-risk cases with isolated or nonisolated aortic arch aneurysms.

1 May 2003 in Heart & Lung
Verified
Journal Article
Closed access
PDF file
AGAli Gürbüz
Ali Gürbüz
UYUfuk Yetkin
Ufuk Yetkin
LYLevent Yilik
Levent Yilik
TÖTurkan Özdemir
Turkan Özdemir
FTFigen Türk
Figen Türk

28 February 2022 in Vascular
Verified
Journal Article
Closed access
YBYuksel Besir
Yuksel Besir
EKErturk Karaagac
Erturk Karaagac
MKMeltem Kurus
Meltem Kurus
EKErdi Keselik
Erdi Keselik
ŞİŞahin İşcan
Şahin İşcan
AGAli Gurbuz
Ali Gurbuz
Objectives: In addition to the hemostatic properties of hemostatic agents, the investigation of their immunogenic properties, their local effects on application area has been the subject of many experimental studies. There are limited data on the inflammatory effects of Bovine serum albumin-glutaraldehyde and Polyethylene glycol polymer. Therefore, we investigated the effects of these agents on tissue reactions and inflammation in rabbit carotid artery anastomosis in our experimental study. Methods: Twenty-one New Zealand male rabbits were randomly divided into three groups. The right carotid artery anastomosis was performed on the control group after transection. Hemostatic agents were applied locally to other two groups separately after transection and anastomosis. At the end of 28 days, the type of inflammation, inflammatory cell infiltration, degree of inflammation, and amount of residual adhesives were examined and compared statistically. Results: Cell infiltrations associated with inflammation on the anastomosis site (eosinophils, epithelioid/giant cells, lymphocytes, and plasma cells) and inflammation grade in the groups of hemostatic agents were significantly lower compared to the control group ( p < .05). There was no difference between the hemostatic agents. While mild inflammation (61.9%) was dominant in the groups of hemostatic agents, moderate inflammation (85.7%) was more common in the control group. No severe inflammation was observed in any of the three groups. Residual sealant grade between hemostatic agents did not differ significantly. Conclusions: When inflammation and tissue reactions of the 4th week were evaluated, it was determined that both hemostatic agents did not cause severe inflammation. However, comparative results at multiple time intervals are needed due to the dynamic process of inflammation.

1 January 2005 in International Heart Journal
Verified
Journal Article
Open access
MKMert Kestelli
Mert Kestelli
LYLevent Yilik
Levent Yilik
IOIbrahim Ozsöyler
Ibrahim Ozsöyler
Şahin BozokŞahin Bozok
Şahin Bozok
BEBilgin Emrecan
Bilgin Emrecan
AGAli Gurbuz
Ali Gurbuz
A newly designed multiplaned mechanical aortic valve was created in which there would be an angle between the stents so the valve would have a greater orifice area. This study was performed to test this valve on bovine aorta to determine whether or not there would be a pressure gradient on both sides of the valve. The valve created is multiplaned with one stent thought to be seated on the aortic annulus for the coronary orifices to receive blood in diastole, whereas the other stent is thought to be seated on the ascending aorta obliquely to increase the orifice area of the valve. The ascending aorta could be enlarged if necessary. A multiplaned valve resembling the valve which has two planes was tested on a Dacron tube, one side of which was formed with a bovine aorta. Pressure readings before and after the bovine aorta was thinned were taken when a 17 L/min flow through the tube was maintained. A 65 mmHg mean pressure gradient and a zero pressure gradient were produced before and after thinning the bovine aorta. The multiplaned mechanical aortic valve produces no gradient if the aorta is elastic. This valve can solve the gradient problem in aortic valve surgery because the aorta is a living and elastic tissue.

1 July 2017 in The Annals of Thoracic Surgery
Verified
Journal Article
Open access
PDF file
OGOrhan Gokalp
Orhan Gokalp
BEBortecin Eygi
Bortecin Eygi
YBYuksel Besir
Yuksel Besir
HIHasan Iner
Hasan Iner
GGGamze Gokalp
Gamze Gokalp
AGAli Gurbuz
Ali Gurbuz

1 October 2025 in Turkish Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
IYIsmail Yurekli
Ismail Yurekli
HIHasan İnEr
Hasan İnEr
SYSerkan Yazman
Serkan Yazman
OGOrhan Gökalp
Orhan Gökalp
HÇHabib Çakır
Habib Çakır
AGAli Gürbüz
Ali Gürbüz
Background: This study aims to examine factors influencing mortality and reintervention among endovascular aortic aneurysm repair patients treated over nearly two decades in the first hybrid operating room of Türkiye. Methods: Between December 2006 and December 2020, a total of 372 patients (349 males, 23 females; mean age: 70.4±8.2 years; range, 45 to 89 years) who underwent endovascular aortic aneurysm repair were retrospectively analyzed. Independent predictors of 30-day, one-year, and five-year mortality rate were identified. The Kaplan-Meier analyses compared outcomes across surgical approaches and graft types. Results: Mortality rates were 6.5% at 30 days, 14.2% at one year, and 21.8% at five years. Multivariate analysis identified postoperative complications (hazard ratio [HR]=3.68, p=0.034), elevated creatinine (HR=1.58, p=0.004), prolonged intubation (HR=1.01, p<0.001), and increased blood transfusion volume (HR=1.17, p=0.003) as independent predictors of 30-day mortality. Advanced age emerged as a significant predictor of five-year mortality (HR=1.09, p<0.001). Elective procedures and bi-iliac grafts demonstrated significantly improved survival across all timeframes (p<0.001). Conclusion: This real-world analysis identifies several procedural and patient-related factors associated with mortality following endovascular aortic aneurysm repair. Postoperative care indicators consistently demonstrated stronger independent associations with mortality than anatomical or demographic factors, highlighting the importance of comprehensive perioperative care optimization in endovascular aortic aneurysm repair management.