Erick Javier López Sánchez

Erick Javier López Sánchez

Auto-generated profile, based on publicly available information

Erick Javier López Sánchez

Posgrado en Ciencias Naturales e Ingeniería, Universidad Autónoma Metropolitana, Cuajimalpa and Vasco de Quiroga 4871, Santa Fe Cuajimalpa, Ciudad de México 05300, México

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2017 in Physical Review E
Verified
Journal Article
Closed access
PDF file
ELErick J. López-Sánchez
Erick J. López-Sánchez
JRJuan M. Romero
Juan M. Romero
The cable equation describes the voltage in a straight cylindrical cable, and this model has been employed to model electrical potential in dendrites and axons. However, sometimes this equation might give incorrect predictions for some realistic geometries, in particular when the radius of the cable changes significantly. Cables with a nonconstant radius are important for some phenomena, for example, discrete swellings along the axons appear in neurodegenerative diseases such as Alzheimers, Parkinsons, human immunodeficiency virus associated dementia, and multiple sclerosis. In this paper, using the Frenet-Serret frame, we propose a generalized cable equation for a general cable geometry. This generalized equation depends on geometric quantities such as the curvature and torsion of the cable. We show that when the cable has a constant circular cross section, the first fundamental form of the cable can be simplified and the generalized cable equation depends on neither the curvature nor the torsion of the cable. Additionally, we find an exact solution for an ideal cable which has a particular variable circular cross section and zero curvature. For this case we show that when the cross section of the cable increases the voltage decreases. Inspired by this ideal case, we rewrite the generalized cable equation as a diffusion equation with a source term generated by the cable geometry. This source term depends on the cable cross-sectional area and its derivates. In addition, we study different cables with swelling and provide their numerical solutions. The numerical solutions show that when the cross section of the cable has abrupt changes, its voltage is smaller than the voltage in the cylindrical cable. Furthermore, these numerical solutions show that the voltage can be affected by geometrical inhomogeneities on the cable.

1 November 2013 in European Journal of Mechanics - B/Fluids
Verified
Journal Article
Closed access
ELErick J. López-Sánchez
Erick J. López-Sánchez
GRGerardo Ruiz-Chavarría
Gerardo Ruiz-Chavarría

20 September 2017 in Physical Review E
Verified
Journal Article
Closed access
PDF file
ELErick J. López-Sánchez
Erick J. López-Sánchez
JRJuan M. Romero
Juan M. Romero
HYH. Yepez-Martinez
H. Yepez-Martinez
Different experimental studies have reported anomalous diffusion in brain tissues and notably this anomalous diffusion is expressed through fractional derivatives. Axons are important to understand neurodegenerative diseases such as multiple sclerosis, Alzheimer's disease, and Parkinson's disease. Indeed, abnormal accumulation of proteins and organelles in axons is a hallmark of these diseases. The diffusion in the axons can become anomalous as a result of this abnormality. In this case the voltage propagation in axons is affected. Another hallmark of different neurodegenerative diseases is given by discrete swellings along the axon. In order to model the voltage propagation in axons with anomalous diffusion and swellings, in this paper we propose a fractional cable equation for a general geometry. This generalized equation depends on fractional parameters and geometric quantities such as the curvature and torsion of the cable. For a cable with a constant radius we show that the voltage decreases when the fractional effect increases. In cables with swellings we find that when the fractional effect or the swelling radius increases, the voltage decreases. Similar behavior is obtained when the number of swellings and the fractional effect increase. Moreover, we find that when the radius swelling (or the number of swellings) and the fractional effect increase at the same time, the voltage dramatically decreases.

26 June 2016
Verified
Book Chapter
Open access
PDF file
ELE. J. López-Sánchez
E. J. López-Sánchez
CGC. D. García-Molina
C. D. García-Molina
GRG. Ruiz-Chavarría
G. Ruiz-Chavarría
AMAbraham Medina
Abraham Medina
At the outlet of estuary-like systems, three vortices are formed: a dipole and a spanwise vortex. The spanwise vortex is formed due to the separation of the bottom boundary layer, just in front of the dipole. If a step occurs at the bottom in the channel output, a single vortex will be formed, the dipole becomes a part of a structure having a horseshoe shape. In a periodic driving flow, after a while this structure results in a dipole and a spanwise vortex. To study in laboratory this kind of vortices we made experiments in a system consisting of two domains connected by a channel in which the flow is induced by a periodic forcing. The channel layer depth is different with respect the depth in the two others domains. In order to investigate this system some measurements of velocity field using PIV were carried out in the vertical plane passing along the channel centerline. On the other hand, the detection of vortices composing the dipole was made with the synthetic Schlieren method. Vortices are low pressure regions, then they produce a deformation of the free surface which can be detected with this method. We observed that at the channel output a horseshoe vortex is formed by the flushing into the open domain. This structure remains for some time, after it decomposes in a dipole and a spanwise vortex. Finally all three vortices are destroyed.

1 April 2021 in Communications - Scientific letters of the University of Zilina
Verified
Journal Article
Open access
PDF file
ELErick Javier Lopez-Sanchez
Erick Javier Lopez-Sanchez
NSNorma Yanet Sanchez-Torres
Norma Yanet Sanchez-Torres
PMPatricia Eugenia Olivera Martinez
Patricia Eugenia Olivera Martinez
Traffic in Mexico City poses a serious problem of vehicle saturation that causes a decrease in speed and increased transport time in the streets that suffer mobility collapses. A macroscopic model of vehicular traffic is used to show the effec...

24 January 2017 in arXiv
Verified
Preprint
Open access
PDF file
ELErick J. López-Sánchez
Erick J. López-Sánchez
JRJuan M. Romero
Juan M. Romero
The cable equation describes the voltage in a straight cylindrical cable, this model has been employed to model electrical potential in dendrites and axons. However, sometimes this equation might give incorrect predictions for some realistic geometries, in particular when the radius of the cable changes significantly. Cables with a non constant radius are important for some phenomena, for example discrete swellings along the axons appear in neurodegenerative diseases such as Alzheimer, Parkinson, HIV-associated dementia and Multiple Sclerosis. In this paper, using the Frenet-Serret frame, we propose a generalized cable equation for a general cable geometry. This generalized equation depends on geometric quantities such as the curvature and torsion of the cable. We show that when the cable has a constant circular cross-section, the first fundamental form of the cable can be simplified and the generalized cable equation depends on neither the curvature nor the torsion of the cable. Additionally, we find an exact solution for an ideal cable which has a particular variable circular cross-section and zero curvature. For this case we show that when the cross-section of the cable increases the voltage decreases. Inspired in this ideal case, we rewrite the generalized cable equation as a diffusion equation with a source term generated by the cable geometry. This source term depends on the cable cross-section area and its derivates. In addition, we study different cables with swelling and provide their numerical solutions. The numerical solutions show that when the cross-section of the cable has abrupt changes, its voltage is smaller than the voltage in the cylindrical cable. Furthermore, these numerical solutions show that the voltage can be affected by geometrical inhomogeneities on the cable.