Ben G. B. Kitchener

Ben G. B. Kitchener

Auto-generated profile, based on publicly available information

Ben G. B. Kitchener

University of Sheffield, Sheffield, UK

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2017 in Progress in Physical Geography: Earth and Environment
Verified
Journal Article
Closed access
BKBen Gb Kitchener
Ben Gb Kitchener
JWJohn Wainwright
John Wainwright
APAnthony J Parsons
Anthony J Parsons
Turbidity of water due to the presence of suspended sediment is measured and interpreted in a variety of ways, which can lead to the misinterpretation of data. This paper re-examines the physics of light scattering in water, and exposes the extent to which the reporting of turbidity data is inconsistent. It is proposed that the cause of this inconsistency is the fact that the accepted turbidity standards USEPA Method 180.1, ISO 7027 and GLI Method 2 are mutually inconsistent, as these standards give rise to a large number of measurement units that are not based on the optical properties of light absorption and scattering by suspensions in water, but by the arbitrary definition of the degree of turbidity being due to a concentration of formazin or other similar polymer-based calibration standard. It is then proposed that all turbidity-measuring devices should be calibrated with precise optical attenuators such as neutral density filters. Such calibration would allow for the definition of a beam attenuation coefficient for every turbidity-measuring instrument which would be cross-comparable with any other instrument calibrated in the same way. The units for turbidity measurements should be based on attenuation and reported as dB m−1. It is also proposed that a new standard should be drafted according to this attenuation-based method, and this new standard should also define the nomenclature for reporting data collected at any specific scattering angle in terms of an attenuation in dB m−1. The importance of multi-parameter turbidity measurements for the improvement of the quality of turbidity data and the application of parameter-rich data sets to new methods of sediment characterization are discussed. It is suggested that more research into multi-parameter turbidity measurements is needed, as these new methods will facilitate an increase in parity between turbidity and suspended sediment concentration, a relationship that is subjective.

3 March 2014 in Physical Review E
Verified
Journal Article
Open access
ELEdward J. Long
Edward J. Long
GHGraham K. Hargrave
Graham K. Hargrave
JCJames R. Cooper
James R. Cooper
BKBen G. B. Kitchener
Ben G. B. Kitchener
APAnthony Parsons
Anthony Parsons
JWJohn Wainwright
John Wainwright
An experimental investigation into the interaction that occurs between an impacting water droplet and a granular bed of loose graded sand has been carried out. High-speed imaging, three-dimensional time-resolved particle tracking, and photogrammetric surface profiling have been used to examine individual impact events. The focus of the study is the quantification and trajectory analysis of the particles ejected from the sand bed, along with measurement of the change in bed morphology. The results from the experiments have detailed two distinct mechanisms of particle ejection: the ejection of water-encapsulated particles from the edge of the wetted region and the ejection of dry sand from the periphery of the impact crater. That the process occurs by these two distinct mechanisms has hitherto been unobserved. Presented in the paper are distributions of the particle ejection velocities, angles, and transport distances for both mechanisms. The ejected water-encapsulated particles, which are few in number, are characterized by low ejection angles and high ejection velocities, leading to large transport distances; the ejected dry particles, which are much greater in number, are characterized by high ejection angles and low velocities, leading to lower transport distances. From the particle ejection data, the momentum of the individual ballistic sand particles has been calculated; it was found that only 2% of the water-droplet momentum at impact is transferred to the ballistic sand particles. In addition to the particle tracking, surface profiling of the granular bed postimpact has provided detailed information on its morphology; these data have demonstrated the consistent nature of the craters produced by the impact and suggest that particle agglomerations released from their edges make up about twice the number of particles involved in ballistic ejection. It is estimated that, overall, about 4% of the water-droplet momentum is taken up in particle movement.

1 April 2019 in HardwareX
Verified
Journal Article
Open access
BKBen G.B. Kitchener
Ben G.B. Kitchener
SDSimon D. Dixon
Simon D. Dixon
KHKieren O. Howarth
Kieren O. Howarth
APAnthony Parsons
Anthony Parsons
JWJohn Wainwright
John Wainwright
CHCaspar J.M. Hewett
Caspar J.M. Hewett

6 December 2012 in Journal of Geophysical Research: Earth Surface
Verified
Journal Article
Closed access
PDF file
JCJames Cooper
James Cooper
JWJohn Wainwright
John Wainwright
APAnthony Parsons
Anthony Parsons
YOYuichi Onda
Yuichi Onda
TFTomomi Fukuwara
Tomomi Fukuwara
GHGraham H. Hargrave
Graham H. Hargrave

20 November 2003
Verified
Conference Paper
Closed access
CBC.M. Buttar
C.M. Buttar
PBP.A. Booth
P.A. Booth
IDI. Dawson
I. Dawson
PDP.J. Dervan
P.J. Dervan
MGM. Glaser
M. Glaser
RNR. Nicholson
R. Nicholson
The current damage parameter, /spl alpha/ and the acceptor damage factor, /spl beta/, of silicon detectors are extracted from an analysis of the evolution of the detector dark current during irradiation. The irradiations were carried out in the CERN PS 23GeV proton beam up to a fluence of (3.00 /spl plusmn/ 0.03)/spl times/10/sup 14/ pcm/sup -2/ and at PSI with pions of energy 191 MeV up to a fluence of (4.5 /spl plusmn/ 0.5)/spl times/10/sup 14/ /spl pi/cm/sup -2/. In this paper we describe the irradiation setup and present the analysis that is used to extract the damage factors. The values of /spl alpha/ normalized to 20/spl deg/C from the proton and pion irradiations are: /spl alpha//sub p/=(4.84 /spl plusmn/ 0.13)/spl times/10/sup -17/ Acm/sup -1/ and /spl alpha//sub /spl pi//=(1.2 /spl plusmn/ 0.2)/spl times/10/sup -16/ Acm/sup -1/ respectively. The values of /spl beta/ from the proton and pion irradiations are /spl beta//sub p/=0063 /spl plusmn/ 0.0018 cm/sup -1/ and /spl beta//sub /spl pi// = 0.07 /spl plusmn/ 0.02 in the temperature range -7/spl deg/ to -10/spl deg/C. The ratio of current damage factors is: 2.5 /spl plusmn/ 0.4 and agrees with the ratio of calculated non-ionising energy loss.