S.-Q. Liu

S.-Q. Liu

Auto-generated profile, based on publicly available information

S.-Q. Liu

Department of Precision Machinery and Precision Instrumentation, Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China 1 , Hefei 230027, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
CHC.-P. Hao
C.-P. Hao
QYQ.-Q. Yu
Q.-Q. Yu
CYC.-Q. Yuan
C.-Q. Yuan
SLS.-Q. Liu
S.-Q. Liu
DSD. Sheng
D. Sheng
We present in this paper a Herriott-cavity-assisted closed-loop Xe isotope gas comagnetometer. In this system, Xe129 and Xe131 atoms are pumped and probed by polarized Rb atoms and continuously driven by oscillating magnetic fields, whose frequencies are kept on resonance by phase-locked loops. Different from other schemes, we use a Herriott cavity to improve the Rb magnetometer sensitivity instead of the parametric modulation method, and this passive method is designed to improve the system stability while maintaining the sensitivity. This system has demonstrated an angle random walk of 0.06∘/h1/2 and a bias instability of 0.2∘/h (0.15 μHz) with a bandwidth of 1.5 Hz. By adding a closed-loop Rb isotope comagnetometer, we can extend this system to dual simultaneously working comagnetometers sharing the same cell. This extended system has wide applications in precision measurements, where we can simultaneously and independently measure the coupling of anomalous fields with proton spin and neutron spin.

21 April 2023 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
SLS.-Q. Liu
S.-Q. Liu
QYQ.-Q. Yu
Q.-Q. Yu
HZH. Zhou
H. Zhou
DSD. Sheng
D. Sheng
This paper presents a compact low-temperature atomic vector magnetometer for weak-field measurements, using an atomic cell containing two orthogonal multipass cavities. At the working temperature of 75∘C, the magnetic field sensitivities at all three axes are better than 45fTHz−1/2 at 10 Hz limited by photon noise, and 85fTHz−1/2 at 0.1 Hz. This sensor also shows measurement stabilities better than 1.5 pT at three axes for an integration time of 104s, even with the laser frequency unlocked. The sensor response to a rotation is demonstrated, which is also developed to measure the effective gyromagnetic ratio of atoms in this sensor when the bias field is nulled. This magnetometer makes an important step towards long-term stable measurements and calibrations of ultralow fields.

1 May 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HZH. Zhou
H. Zhou
XWX.-K. Wang
X.-K. Wang
SLS.-Q. Liu
S.-Q. Liu
LCL. Cheng
L. Cheng
KLK. Liu
K. Liu
YWY.-M. Wang
Y.-M. Wang
We present the electronics developed for a sensitive and stable atomic vector magnetometer used in low-field detections. These electronics are required to be not only highly reliable and sophisticated for signal processing but also compact in size and low cost in resource consumption for the purpose of miniaturization. In addition, this magnetometer works with multiple modulations, where the interferences between harmonics of modulation fields often disturb the long-term measurements of the sensor. We work out a robust method to eliminate this problem by choosing the modulation frequencies with separations to match the minimum response points of the low-pass filters used in the demodulation processes. We validate the performance of the electronics and the frequency-selection scheme of the modulation fields with corresponding experimental results.