Darrel Parthipan Francis

Darrel Parthipan Francis

Auto-generated profile, based on publicly available information

Darrel Parthipan Francis

Imperial College London

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in International Journal of Cardiology
Verified
Journal Article
Closed access
CCChristopher M. Cook
Christopher M. Cook
GCGraham Cole
Graham Cole
PAPerviz Asaria
Perviz Asaria
RJRichard Jabbour
Richard Jabbour
DFDarrel P. Francis
Darrel P. Francis

24 March 2018 in European Heart Journal
Verified
Journal Article
Open access
YAYousif Ahmad
Yousif Ahmad
JHJames P Howard
James P Howard
AAAhran Arnold
Ahran Arnold
MSMatthew Shun Shin
Matthew Shun Shin
CCChristopher Cook
Christopher Cook
SSSayan Sen
Sayan Sen
The efficacy of patent foramen ovale (PFO) closure for cryptogenic stroke has been controversial. We undertook a meta-analysis of randomized controlled trials (RCTs) comparing device closure with medical therapy to prevent recurrent stroke for patients with PFO. We systematically identified all RCTs comparing device closure to medical therapy for cryptogenic stroke in patients with PFO. The primary efficacy endpoint was recurrent stroke, analysed on an intention-to-treat basis. The primary safety endpoint was new onset atrial fibrillation (AF). Five studies (3440 patients) were included. In all, 1829 patients were randomized to device closure and 1611 to medical therapy. Across all patients, PFO closure was superior to medical therapy for prevention of stroke [hazard ratio (HR) 0.32, 95% confidence interval (95% CI) 0.13-0.82; P = 0.018, I2 = 73.4%]. The risk of AF was significantly increased with device closure [risk ratio (RR) 4.68, 95% CI 2.19-10.00, P<0.001, heterogeneity I2 = 27.5%)]. In patients with large shunts, PFO closure was associated with a significant reduction in stroke (HR 0.33, 95% CI 0.16-0.72; P = 0.005), whilst there was no significant reduction in stroke in patients with a small shunt (HR 0.90, 95% CI 0.50-1.60; P = 0.712). There was no effect from the presence or absence of an atrial septal aneurysm on outcomes (P = 0.994). In selected patients with cryptogenic stroke, PFO closure is superior to medical therapy for the prevention of further stroke: this is particularly true for patients with moderate-to-large shunts. Guidelines should be updated to reflect this.

29 August 2020 in European Heart Journal
Verified
Journal Article
Open access
PDF file
SHShouvik Haldar
Shouvik Haldar
HKHabib Rehman Khan
Habib Rehman Khan
VBVennela Boyalla
Vennela Boyalla
IKInes Kralj-Hans
Ines Kralj-Hans
SJSimon Jones
Simon Jones
TWTom Wong
Tom Wong
Long-standing persistent atrial fibrillation (LSPAF) is challenging to treat with suboptimal catheter ablation (CA) outcomes. Thoracoscopic surgical ablation (SA) has shown promising efficacy in atrial fibrillation (AF). This multicentre randomized controlled trial tested whether SA was superior to CA as the first interventional strategy in de novo LSPAF. We randomized 120 LSPAF patients to SA or CA. All patients underwent predetermined lesion sets and implantable loop recorder insertion. Primary outcome was single procedure freedom from AF/atrial tachycardia (AT) ≥30 s without anti-arrhythmic drugs at 12 months. Secondary outcomes included clinical success (≥75% reduction in AF/AT burden); procedure-related serious adverse events; changes in patients’ symptoms and quality-of-life scores; and cost-effectiveness. At 12 months, freedom from AF/AT was recorded in 26% (14/54) of patients in SA vs. 28% (17/60) in the CA group [OR 1.128, 95% CI (0.46–2.83), P = 0.83]. Reduction in AF/AT burden ≥75% was recorded in 67% (36/54) vs. 77% (46/60) [OR 1.13, 95% CI (0.67–4.08), P = 0.3] in SA and CA groups, respectively. Procedure-related serious adverse events within 30 days of intervention were reported in 15% (8/55) of patients in SA vs. 10% (6/60) in CA, P = 0.46. One death was reported after SA. Improvements in AF symptoms were greater following CA. Over 12 months, SA was more expensive and provided fewer quality-adjusted life-years (QALYs) compared with CA (0.78 vs. 0.85, P = 0.02). Single procedure thoracoscopic SA is not superior to CA in treating LSPAF. Catheter ablation provided greater improvements in symptoms and accrued significantly more QALYs during follow-up than SA. ISRCTN18250790 and ClinicalTrials.gov: NCT02755688

1 September 2014 in JACC
Verified
Journal Article
Closed access
MRMichael R. Rosen
Michael R. Rosen
RMRobert J. Myerburg
Robert J. Myerburg
DFDarrel P. Francis
Darrel P. Francis
GCGraham D. Cole
Graham D. Cole
EMEduardo Marbán
Eduardo Marbán

28 October 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
FSFlorentina A Simader
Florentina A Simader
JHJames P Howard
James P Howard
YAYousif Ahmad
Yousif Ahmad
KSKeenan Saleh
Keenan Saleh
ANAkriti Naraen
Akriti Naraen
AAAhran D Arnold
Ahran D Arnold
The effect of atrial fibrillation catheter ablation on cardiovascular outcomes in heart failure is an important outstanding research question. We undertook a meta-analysis of randomized controlled trials comparing ablation to medical therapy in patients with AF and heart failure. We systematically identified all trials comparing catheter ablation to medical therapy in patients with heart failure and atrial fibrillation. The pre-specified primary endpoint was all-cause mortality in trials with at least 2 years of follow-up. The secondary endpoint was heart failure hospitalization. Sensitivity analyses were performed for trials with any follow-up and trials deemed at low risk of bias. Eight trials (1390 patients) were included. Seven hundred and seven patients were randomized to catheter ablation and 683 to medical therapy. In the primary analysis (three trials, n = 977), catheter ablation reduced mortality compared with medical therapy [relative risk (RR): 0.61, 95% confidence interval (CI): 0.44 to 0.84, P = 0.003]. Catheter ablation also reduced heart failure hospitalizations compared with medical therapy (RR: 0.60, 95% CI: 0.49–0.74, P < 0.001). The effect on stroke was not statistically significant (RR: 0.62, 95% CI: 0.28–1.37, P = 0.237). There was low heterogeneity between studies. Sensitivity analyses were consistent with the primary analyses. In patients with atrial fibrillation and heart failure, catheter ablation reduces mortality and the occurrence of heart failure hospitalizations.

3 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
NANadine Ali
Nadine Ali
AAAhran D Arnold
Ahran D Arnold
AMAlejandra A Miyazawa
Alejandra A Miyazawa
DKDaniel Keene
Daniel Keene
JCJi-Jian Chow
Ji-Jian Chow
ZWZachary I Whinnett
Zachary I Whinnett
Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP −35 ± 20 ms vs. ΔTVATBVP −19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (−46 ± 15 ms, −36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP −43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP −45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP −13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.