1 April 2014 in Journal of Wind Engineering and Industrial Aerodynamics
1 September 2016 in Journal of Physics: Conference Series
14 March 2019 in Wind Energy Science
This paper studies a closed-loop wind farm control framework for active power control (APC) with a simultaneous reduction of wake-induced structural loads within a fully developed wind farm flow interacting with the atmospheric boundary layer. The main focus is on a classical feedback control, which features a simple control architecture and a practical measurement system that are realizable for real-time control of large wind farms. We demonstrate that the wake-induced structural loading of the downstream turbines can be alleviated, while the wind farm power production follows a reference signal. A closed-loop APC is designed first to improve the power-tracking performance against wake-induced power losses of the downwind turbines. Then, the nonunique solution of APC for the wind farm is exploited for aggregated structural load alleviation. The axial induction factors of the individual wind turbines are considered control inputs to limit the power production of the wind farm or to switch to greedy control when the demand exceeds the power available in the wind. Furthermore, the APC solution domain is enlarged by an adjustment of the power set-points according to the locally available power at the waked wind turbines. Therefore, the controllability of the wind turbines is improved for rejecting the intensified load fluctuations inside the wake. A large-eddy simulation model is employed for resolving the turbulent flow, the wake structures, and its interaction with the atmospheric boundary layer. The applicability and key features of the controller are discussed with a wind farm example consisting of 3×4 turbines with different wake interactions for each row. The performance of the proposed APC is evaluated using the accuracy of the wind farm power tracking and the wake-induced damage equivalent fatigue loads of the towers of the individual wind turbines.
1 October 2017 in Renewable Energy
11 August 2020 in Wind Energy
The reduction of structural loads is becoming an important objective for the wind turbine control system due to the ever‐increasing specifications/demands on wind turbine rated power and related growth of turbine dimensions. Among various control algorithms that have been researched in recent years, the individual pitch control has demonstrated its effectiveness in wind turbine load reduction. Since the individual pitch control, like other load reduction algorithms, requires higher levels of actuator activity, one must take actuator constraints into account when designing the controller. This paper presents a method for the inclusion of such constraints into a predictive wind turbine controller. It is shown that the direct inclusion of constraints would result in a control problem that is nonconvex and difficult to solve. Therefore, a modification of the constraints is proposed that ensures the convexity of the control problem. Simulation results show that the developed predictive control algorithm achieves individual pitch control objectives while satisfying all imposed constraints.