Josef Kautzner

Josef Kautzner

Auto-generated profile, based on publicly available information

Josef Kautzner

Department of Cardiology, Institute for Clinical and Experimental Medicine , Prague, Czechia

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2023 in Circulation
Verified
Journal Article
Closed access
MTMohit K. Turagam
Mohit K. Turagam
PNPetr Neuzil
Petr Neuzil
BSBoris Schmidt
Boris Schmidt
TRTobias Reichlin
Tobias Reichlin
KNKars Neven
Kars Neven
VRVivek Y. Reddy
Vivek Y. Reddy
Background: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. Methods: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (7 days) major adverse events. Results: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA 2 DS 2 -VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289–421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%–80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P =0.001). Acute major adverse events occurred in 1.9% of patients. Conclusions: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.

1 June 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
EEEmmanuel Ekanem
Emmanuel Ekanem
VRVivek Y Reddy
Vivek Y Reddy
BSBoris Schmidt
Boris Schmidt
TRTobias Reichlin
Tobias Reichlin
KNKars Neven
Kars Neven
MCMANIFEST-PF Cooperative
MANIFEST-PF Cooperative
Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the ‘real world’ performance of the only approved PFA catheter, including acute effectiveness and safety—in particular, rare oesophageal effects and other unforeseen PFA-related complications. This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7–291), full cohort included 1758 patients: mean age 61.6 years (range 19–92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9–100%). Procedure time was 65 min (38–215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of ‘generic’ catheter complications (tamponade, stroke) underscores the need for improvement.

3 June 2015 in EP Europace
Verified
Journal Article
Open access
PDF file
JKJosef Kautzner
Josef Kautzner
PNPetr Neuzil
Petr Neuzil
HLHendrik Lambert
Hendrik Lambert
PPPetr Peichl
Petr Peichl
JPJan Petru
Jan Petru
KKKarl-Heinz Kuck
Karl-Heinz Kuck
A challenge of pulmonary vein isolation (PVI) in catheter ablation for paroxysmal atrial fibrillation (PAF) is electrical reconnection of the PV. EFFICAS I showed correlation between contact force (CF) parameters and PV durable isolation but no prospective evaluation was made. EFFICAS II was a multicentre study to prospectively assess the impact of CF guidance for an effective reduction of PVI gaps. Pulmonary vein isolation using a radiofrequency (RF) ablation catheter with an integrated force sensor (TactiCath™) was performed in patients with PAF. Operators were provided EFFICAS I-based CF guidelines [target 20 g, range 10–30 g, minimum 400 g s force-time integral (FTI)]. Conduction gaps were assessed by remapping of PVs after 3 months, and gap rate was compared with EFFICAS I outcome. At follow up, 24 patients had 85% of PVs remaining isolated, compared with 72% in EFFICAS I (P = 0.037) in which CF guidelines were not used. The remaining 15% of gaps correlated to the number of catheter moves at creating the PVI line, quantified as Continuity Index. For PV lines with contiguous lesions and low catheter moves, durable isolation was 81% in EFFICAS I and 98% in EFFICAS II (P = 0.005). At index procedure, the number of lesions was reduced by 15% in EFFICAS II vs. EFFICAS I. The use of CF with the above guidelines and contiguous deployment of RF lesions in EFFICAS II study resulted in more durable PVI in catheter ablation of PAF.

1 June 2020 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
VRVivek Y. Reddy
Vivek Y. Reddy
EAElad Anter
Elad Anter
GRGediminas Rackauskas
Gediminas Rackauskas
PPPetr Peichl
Petr Peichl
JKJacob S. Koruth
Jacob S. Koruth
PNPetr Neuzil
Petr Neuzil
Background: The tissue selectivity of pulsed field ablation (PFA) provides safety advantages over radiofrequency ablation in treating atrial fibrillation. One-shot PFA catheters have been shown capable of performing pulmonary vein isolation, but not flexible lesion sets such as linear lesions. A novel lattice-tip ablation catheter with a compressible 9-mm nitinol tip is able to deliver either focal radiofrequency ablation or PFA lesions, each in 2 to 5 s. Methods: In a 3-center, single-arm, first-in-human trial, the 7.5F lattice catheter was used with a custom mapping system to treat paroxysmal or persistent atrial fibrillation. Toggling between energy sources, point-by-point pulmonary vein encirclement was performed using biphasic PFA posteriorly and either temperature-controlled irrigated radiofrequency ablation or PFA anteriorly (RF/PF or PF/PF, respectively). Linear lesions were created using either PFA or radiofrequency ablation. Results: The 76-patient cohort included 55 paroxysmal and 21 persistent atrial fibrillation patients undergoing either RF/PF (40 patients) or PF/PF (36 patients) ablation. The pulmonary vein isolation therapy duration time (transpiring from first to last lesion) was 22.6±8.3 min/patient, with a mean of 50.1 RF/PF lesions/patient. Linear lesions included 14 mitral (4 RF/2 RF+PF/8 PF), 34 left atrium roof (12 RF/22 PF), and 44 cavotricuspid isthmus (36 RF/8 PF) lines, with therapy duration times of 5.1±3.5, 1.8±2.3, and 2.4±2.1 min/patient, respectively. All lesion sets were acutely successful, using 4.7±3.5 minutes of fluoroscopy. There were no device-related complications, including no strokes. Postprocedure esophagogastroduodenoscopy revealed minor mucosal thermal injury in 2 of 36 RF/PF and 0 of 24 PF/PF patients. Postprocedure brain magnetic resonance imaging revealed diffusion-weighted imaging+/fluid-attenuated inversion recovery- and diffusion-weighted imaging+/fluid-attenuated inversion recovery+ asymptomatic lesions in 5 and 3 of 51 patients, respectively. Conclusions: A novel lattice-tip catheter could safely and rapidly ablate atrial fibrillation using either a combined RF/PF approach (capitalizing on the safety of PFA and the years of experience with radiofrequency energy) or an entirely PF approach. Registration: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT04141007 and NCT04194307.

17 January 2025 in EP Europace
Verified
Journal Article
Open access
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
MTMohit K Turagam
Mohit K Turagam
PMPhilippe Maury
Philippe Maury
YBYuri Blaauw
Yuri Blaauw
PVPepijn van der Voort
Pepijn van der Voort
VRVivek Y Reddy
Vivek Y Reddy
Aims: Initial clinical studies of pulsed field ablation (PFA) to treat atrial fibrillation (AF) indicated a >90% durability rate of pulmonary vein isolation (PVI). However, these studies were largely conducted in single centres and involved a limited number of operators. We aimed to describe the electrophysiological findings and outcomes in patients undergoing repeat ablation after an initial PF ablation for AF. Methods and results: In the MANIFEST-REDO study, we investigated patients who underwent repeat ablation due to clinical recurrence—AF or atrial tachycardia (AT)—following first-ever PVI with a pentaspline PFA catheter (Farawave, Boston Scientific Inc.). At 22 centres, 427 patients (age 64 ± 11 years; 37% female) were included. Of note, the recurrent arrhythmia leading to the repeat ablation was paroxysmal AF (51%), persistent AF (30%), or AT (19%). At the repeat procedure, the PV reconnection rates were 30% (left superior pulmonary vein), 28% (left inferior pulmonary vein), 33% (right superior pulmonary vein), and 32% (right inferior pulmonary vein). In 45% of patients, all PVs were durably isolated at the beginning of the repeat procedure, with the previous use of any imaging or mapping modality being univariately associated with durable PVI. After a post-redo follow-up period of 284 (90–366) days, the primary effectiveness endpoint (freedom from documented AF/AT lasting ≥30 s after 3-month blanking without class I/III antiarrhythmic drugs or symptoms) was achieved in 65% of patients, with significant differences between groups (PAF 65% vs. PersAF 56% vs. AT 76%; P = 0.04). Persistent AF as recurrent arrhythmia after the initial PFA ablation predicted AT/AF recurrence after repeat ablation [hazard ratio 1.241 (95% confidence interval 1.534–1.005); P = 0.045]. The procedural complication rate was 2.8%. Conclusion: In repeat procedures for AF/AT performed after an index procedure with PFA for AF, PV reconnections are not uncommon. Repeat procedures can be performed safely and with an acceptable subsequent success rate.

8 October 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
NPNiels Peek
Niels Peek
GHGerhard Hindricks
Gerhard Hindricks
AAArtur Akbarov
Artur Akbarov
JTJan G P Tijssen
Jan G P Tijssen
DJDavid A Jenkins
David A Jenkins
NDNikolaos Dagres
Nikolaos Dagres
Risk stratification of sudden cardiac death after myocardial infarction and prevention by defibrillator rely on left ventricular ejection fraction (LVEF). Improved risk stratification across the whole LVEF range is required for decision-making on defibrillator implantation. The analysis pooled 20 data sets with 140 204 post-myocardial infarction patients containing information on demographics, medical history, clinical characteristics, biomarkers, electrocardiography, echocardiography, and cardiac magnetic resonance imaging. Separate analyses were performed in patients (i) carrying a primary prevention cardioverter-defibrillator with LVEF ≤ 35% [implantable cardioverter-defibrillator (ICD) patients], (ii) without cardioverter-defibrillator with LVEF ≤ 35% (non-ICD patients ≤ 35%), and (iii) without cardioverter-defibrillator with LVEF > 35% (non-ICD patients >35%). Primary outcome was sudden cardiac death or, in defibrillator carriers, appropriate defibrillator therapy. Using a competing risk framework and systematic internal–external cross-validation, a model using LVEF only, a multivariable flexible parametric survival model, and a multivariable random forest survival model were developed and externally validated. Predictive performance was assessed by random effect meta-analysis. There were 1326 primary outcomes in 7543 ICD patients, 1193 in 25 058 non-ICD patients ≤35%, and 1567 in 107 603 non-ICD patients >35% during mean follow-up of 30.0, 46.5, and 57.6 months, respectively. In these three subgroups, LVEF poorly predicted sudden cardiac death (c-statistics between 0.50 and 0.56). Considering additional parameters did not improve calibration and discrimination, and model generalizability was poor. More accurate risk stratification for sudden cardiac death and identification of low-risk individuals with severely reduced LVEF or of high-risk individuals with preserved LVEF was not feasible, neither using LVEF nor using other predictors. Brief summary of the background, methodology, and results of the PROFID data analysis. ICD patients, patients with left ventricular ejection fraction ≤ 35% who had received a cardioverter-defibrillator implantation for primary prevention of sudden cardiac death; non-ICD patients ≤35%, patients who did not carry a cardioverter-defibrillator and had a left ventricular ejection fraction ≤ 35%; and non-ICD patients >35%, patients who did not carry a cardioverter-defibrillator and had a left ventricular ejection fraction > 35%. Detailed inclusion and exclusion criteria are provided in the text. CMR, cardiac magnetic resonance; ICD, implantable cardioverter-defibrillator; LVEF, left ventricular ejection fraction; MI, myocardial infarction.