11 January 2024 in Canadian Journal of Ophthalmology
17 June 2024 in Journal of Cataract & Refractive Surgery Online Case Reports
Introduction: This report describes a challenging case involving the diagnosis and surgical repair of an extensive cyclodialysis cleft (CDC) in a young, phakic patient. Patient and Clinical Findings: A 25-year-old man presented with ocular pain, visual impairment, eyelid hematoma, subconjunctival hemorrhage, and Berlin edema after blunt trauma to the right eye. Initial conservative treatment with medications was converted to surgery due to hypotony-induced maculopathy. Diagnosis, Intervention, and Outcomes: Ultrasound biomicroscopy (UBM) and gonioscopy revealed extensive supraciliary and suprachoroidal fluid and a CDC whose dimensions were inconclusive. However, consequent intraoperative UBM provided precise real-time anatomical evidence of an extensive CDC extending 8 clock hours and mandating closure with a direct cycloplexy approach. Layered scleral dissection and direct suturing of the ciliary body to the sclera were performed with 8-0 nylon sutures, resulting in CDC resolution, supraciliary and suprachoroidal fluid absorption, visual acuity improvement, and intraocular pressure stabilization. Conclusions: This case highlights the innovative use of intraoperative UBM as a critical tool, offering real-time guidance in managing an extensive CDC. The successful closure and improved visual outcomes in this case further validate the efficacy of direct cycloplexy for extensive CDCs.
4 June 2025 in European Journal of Ophthalmology
Purpose: This study aims to introduce an innovative surgical technique for facilitating the insertion and precise positioning of the PreserFlo MicroShunt (PMS) using intraoperative optical coherence tomography (iOCT). Methods: iOCT was employed to determine the transscleral route, entry point into the anterior chamber (AC), trajectory of the PMS within the AC, and final intracameral and scleral positioning of the PMS. Intra- and postoperative outcomes and complications were evaluated. Results: This retrospective study included nine eyes of nine consecutive glaucoma patients who underwent PMS implantation using the new technique. All patients showed a significant reduction in intraocular pressure, without notable complications. In some cases, iOCT identified initial misplacements, enabling immediate intraoperative adjustments and successful repositioning, ensuring precise and safe implantation in all cases. Conclusion: This innovative application of iOCT offers a means to refine the PMS implantation technique by enhancing intraoperative visualization and positioning accuracy. The integration of iOCT has the potential to enhance the surgical techniques of experienced surgeons as well as to improve the training of junior practitioners.