Ariyamehr Rezaei

Ariyamehr Rezaei

Auto-generated profile, based on publicly available information

Ariyamehr Rezaei

Graduate School of Biomedical Engineering and the Tyree Institute of Health Engineering, University of New South Wales (UNSW), Sydney, NSW, Australia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ARAriyamehr Rezaei
Ariyamehr Rezaei
AMAlessandro Mascheroni
Alessandro Mascheroni
MSMichael Charles Stevens
Michael Charles Stevens
RAReza Argha
Reza Argha
MPMichela Papandrea
Michela Papandrea
NLNigel Lovell
Nigel Lovell
As the population ages, health issues like injurious falls demand more attention. One solution is to use wearable devices to detect falls. Nevertheless, most of these devices raise obtrusiveness, and older people generally resist or might forget to wear them. The millimeter-wave (mmWave) radar technology was used in this study to unobtrusively detect human falls. Data were collected from healthy young volunteers with the radar mounted on the side wall (trial 1) or overhead (trial 2) of an experimental room. A set of features was manually extracted from the data point clouds, then multilayer perceptron (MLP), Random Forest (RF), k-nearest neighbor (KNN), and support vector machine (SVM) classifiers were applied on the features. Additionally, we devised a convolutional neural network (CNN)-based deep learning model for the underlying fall detection problem that receives a 3D representation of the point cloud data, known as occupancy grid, as the input. The optimal installation position of the radar sensor was unknown. Therefore, the sensor was mounted on side wall, and on the ceiling of the room to allow the performance comparison between these sensor placements. RF classifier achieved the best results in trial 2 (accuracy of 92.2%, recall of 0.881, precision of 0.805, and F1-score of 0.841), the proposed CNN model achieved slightly better results comparing to the RF method in trial 2 (accuracy of 92.3%, recall of 0.891, precision of 0.801, and F1-score of 0.844). These results suggest the development of an unobtrusive monitoring system for fall detection using mmWave radar is feasible.

27 June 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ARAriyamehr Rezaei
Ariyamehr Rezaei
MSMichael Charles Stevens
Michael Charles Stevens
AAAhmadreza Argha
Ahmadreza Argha
AMAlessandro Mascheroni
Alessandro Mascheroni
Alessandro PuiattiAlessandro Puiatti
Alessandro Puiatti
NLNigel Lovell
Nigel Lovell
Given the aging population, healthcare systems need to be established to deal with health issues such as injurious falls. Wearable devices can be used to detect falls. However, most wearable devices are obtrusive, and patients generally do not like or may forget to wear them. In this study, we developed an unobtrusive monitoring system using infrared technology to unobtrusively detect locations and recognize human activities such as sitting, standing, walking, lying, and falling. We prototyped a system consisting of two 24×32 thermal array sensors and collected data from healthy young volunteers performing ten different scenarios. A supervised deep learning (DL)-based approach classified activities and detected locations from images. The performance of the DL approach was also compared with the machine learning (ML)-based methods. In addition, we fused the data of two sensors and formed a stereo system, which resulted in better performance compared to a single sensor. Furthermore, to detect critical activities such as falling and lying on floor, we performed a binary classification in which one class was falling plus lying on floor and another class was all the remaining activities. Using the DL-based algorithm on the stereo dataset to recognize activities, overall average accuracy and F1-score were achieved as 97.6%, and 0.935, respectively. These scores for location detection were 97.3%, and 0.927, respectively. These scores for binary classification were 97.9%, and 0.945, respectively. Our results suggest the proposed system recognized human activities, detected locations, and detected critical activities namely falling and lying on floor accurately.