Tao Wang

Tao Wang

Auto-generated profile, based on publicly available information

Tao Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2022 in Energy
Verified
Journal Article
Closed access
TWTao Wang
Tao Wang
YZYu Zhang
Yu Zhang
ZYZhao Yin
Zhao Yin
LQLiang Qiu
Liang Qiu
YHYang Hua
Yang Hua
YQYe-Jian Qian
Ye-Jian Qian

14 October 2023 in Fuel
Verified
Journal Article
Closed access
XWXiaofei Wei
Xiaofei Wei
YQYejian Qian
Yejian Qian
ZGZhen Gong
Zhen Gong
SMShun Meng
Shun Meng
YSYu Sun
Yu Sun
TWTao Wang
Tao Wang

19 October 2023 in Energy
Verified
Journal Article
Closed access
TWTao Wang
Tao Wang
YZYu Zhang
Yu Zhang
ZYZhao Yin
Zhao Yin
HZHua-Liang Zhang
Hua-Liang Zhang
YQYe-Jian Qian
Ye-Jian Qian

25 September 2023 in Fuel
Verified
Journal Article
Closed access
YZYu Zhang
Yu Zhang
QZQuanqing Zhang
Quanqing Zhang
TZTaotao Zhou
Taotao Zhou
LQLiang Qiu
Liang Qiu
TWTao Wang
Tao Wang
YQYejian Qian
Yejian Qian

13 January 2025 in Energy
Verified
Journal Article
Closed access
TWTao Wang
Tao Wang
GCGen Chi
Gen Chi
HZHua-Liang Zhang
Hua-Liang Zhang
YZYu Zhang
Yu Zhang
YQYe-Jian Qian
Ye-Jian Qian

24 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
TWTao Wang
Tao Wang
FZFeng Zhang
Feng Zhang
PRPeng Ren
Peng Ren
ZYZhao Yin
Zhao Yin
XFXiangjun Fang
Xiangjun Fang
The water-enhanced turbofan (WET) is an emerging engine concept with the potential to substantially reduce fuel consumption and emissions. Its condenser is a key component that enables water condensation by cooling the core exhaust to induce condensation. Existing designs are constrained by small heat-transfer temperature differences, high mass and large pressure losses, limiting WET development. This study proposes a novel aircraft-skin-integrated micro-pin-fin condenser, with pin fins and hot-side passages located on the inner side of the aircraft skin. The configuration uses the high-speed freestream at cruise altitude to cool exhaust through the skin. Models for heat transfer and hot-side pressure loss are developed and validated against three-dimensional CFD simulations and experimental data. Aircraft transport efficiency is adopted as the ultimate design objective to balance condenser mass and hot-side pressure loss. Multi-objective optimization uses the elitist non-dominated sorting genetic algorithm II (NSGA-II). Three-dimensional simulations provide the air-side convective heat-transfer coefficient distribution over the aircraft skin. A simplified design adopts identical condenser units and neglects spatial non-uniformity in this coefficient. A subsequent zonal design divides the installation into six regions according to local air-side heat-transfer coefficients and optimizes the unit geometry and zonal flow allocation. The design result achieves a relative water condensation rate of 100.0%. The selected condenser attains a heat flux of 8.044 kW/m² and a heat transfer per unit mass of 13.683 kW/kg, with a maximum hot-side pressure-loss ratio of 1.708% and a total condenser of 302.154 kg per engine.