1 January 2012 in Thermal Science
Exergy analysis is a universal method for evaluating the rational use of energy. It can be applied to any kind of energy conversion system or chemical process. An exergy analysis identifies the location, the magnitude and the causes of thermodynamic inefficiencies and enhances understanding of the energy conversion processes in complex systems. Conventional exergy analyses pinpoint components and processes with high irreversibility. To overcome the limitations of the conventional analyses and to increase our knowledge about a plant, advanced exergy-based analyses are developed. These analyses provide additional information about component interactions and reveal the real potential for improvement of each component constituting a system, as well as of the overall system. In this paper, a real industrial plant is analyzed using both conventional and advanced exergy analyses, and exergoeconomic evaluation. Some of the exergy destruction in the plant components is unavoidable and constrained by technological, physical and economic limitations. Calculations related to the total avoidable exergy destruction caused by each component of the plant supplement the outcome of the conventional exergy analysis. Based on the all-reaching analysis, by improving the boiler operation (elimination of approximately 1 MW of avoidable exergy destruction in the steam boiler) the greatest improvement in the efficiency of the overall system can be achieved.
1 January 2025 in Thermal Science
The retrofit of existing buildings has a notable potential to save energy and reduce the environmental impact. This paper presents an approach to assess the primary energy saving potential related to the retrofit of a school building. The retrofit includes wall and roof insulation, fenestration replacement, installation of heat pumps with thermal storage, and usage of photovoltaic panels. The approach relies on building simulations and operation optimization evaluate a limited number of retrofit combinations. The results are used to formulate two kinds of surrogate models based on gradient boosting: classifier that finds feasible options and regressor that estimates the primary energy consumption. The results show high precision of the predictive models. The F1 score of the classifiers exceeds 0.99 even for very small training samples. The most important feature for estimating feasibility is the heat pump capacity. The coefficient of determination of the regressors is close to 1 and the root mean square error is lower than 1 kWh/m2, even for moderate sizes of the training set. The most important feature for predicting energy consumption is related to the area and orientation of photovoltaic panels.
1 January 2025 in Thermal Science
Heat pumps are very significant for wide application of RES and sustainable heating. Their market penetration and extensive application depend on economic performance. Optimization of the operation parameters of energy systems with heat pumps can result in lower costs and higher savings. Heat pumps operate under different electricity pricing structures, which affect the optimization process. This paper presents a methodology for cost-optimal operation optimization of hybrid energy systems with heat pumps that can be used with progressive electricity tariffs and their combination with time-of-use tariffs. It relies on mixed integer linear programming and includes the constraints that handle electricity tariff rules. The paper illustrates an example of the application of this methodology to a heating system with an air-source heat pump and an auxiliary heater. The results show the impact of the energy prices and electricity tariff structures on the operating regimes and the values of the objective function. This approach can enhance the quality of the optimization results and improve the comprehension of cost-optimal operation regimes.
1 January 2023 in Thermal Science
Since the reduction of energy consumption and efficient energy use, particularly in the building stock, is the priority for contemporary societies, the ways of how to improve the existing buildings should be examined. Flat roofs, as a part of the existing building thermal envelope, are recognized as a field of intervention for improving efficient energy use for space cooling and heating. The topic of the paper is to determine to what extent different improved roof structures affect energy consumption intended to achieve thermal comfort. Comparative analysis of four roof structures was conducted for the building of Healthcare center Niš in Serbia, one improved non-walkable flat roof structure and three green roof systems. Urbancsape extensive green roof system was used in all tested green roof models: non-walkable extensive green roof, walkable extensive green roof, and extensive and intensive green roof systems within walkable terraces. DesignBuilder software was used for energy modeling. The obtained results indicate a slight decrease in energy consumption for building models with green roofs compared to the building model with the improved non-walkable roof structure, along the cooling period, by approximately 1,5%, which is correlated with previous studies in similar conditions. On the other hand, the reduction of energy consumption over the heating period was negligible (less than 1%). Considering the results and predominant usage of commercial Urbanscape extensive green roof system in all green roof models, being characterized by small thickness (10.64 cm) and light structure, and which is predicted to be installed over the already well-insulated roof, the system’s role as an additional thermal mass was confirmed.
1 January 2025 in Thermal Science
Heat pumps meet the needs of the residential sector through the following three purposes: domestic water heating, space heating and cooling. This paper presents experimental research into the energy performance of an air-to-water heat pump in real summer changeover regimes, given that these are periods that significantly affect the reduction of efficiency. The transition regimes between the two regimes of operation with the most pronounced changes were especially considered. These were the transition regimes characteristic of operation in the summer period, namely: the transition from the space cooling regime to the domestic water reheating regime, and vice versa. In the observed period, the focus has been on 60 readings, with a resolution of 1 minute. In that period two changes in the operating mode were made, from the stationary space cooling regime (when the heat pump prepared water for the underfloor cooling at 17?C) to the domestic water reheating mode (when the heat pump prepared hot water in the tank at 43?C during the day), as well as switching to the previous, cooling mode. The research results show that in the observed period the heat pump worked in stationary regimes of space cooling and domestic water reheating, respectively, with average performance values of 3.52 and 4.75, and average exergetic efficiency of 6.93% and 33.38%.
1 January 2026 in Thermal Science
Urban environments are facing the challenges posed by climate change. As the urban heat island (UHI) effect intensifies, the need for implementing strategies in the context of energy resilience is also growing. The aim of this study was to investigate the impact of integrating green roofs within the existing green infrastructure of an urban area on moderating microclimatic conditions, and consequently the thermal load on buildings. The concept of thermal load is addressed through temperature-based indicators, reflecting the buildings? exposure to outdoor thermal conditions. The microclimatic simulations for the multi-residential urban block (Block 22) in Belgrade were conducted under two scenarios: the ?existing-state? scenario, representing the base condition, and the ?integrated-green-roofs? scenario, representing the implementation of green roofs across all roofing systems. The ENVI-met software was used as a tool for predicting microclimatic conditions, i.e., outdoor air temperatures and fa?ade surface temperatures. The results regarding variations in temperature distribution within the urban block, analyzed through eight horizontal sections, showed slight reductions in the ?integrated-green-roofs? scenario, up to 0.20 ?C in maximum temperatures at the highest section including buildings. Regarding variations in fa?ade surface temperatures, reductions ranged from 0.15 to 0.36?C, also favoring the second scenario. Overall, despite some inconsistencies observed in the study, the indirect positive impact of green roofs in moderating thermal load on entire building envelopes-not only on the roofing systems-was confirmed.