14 November 2017 in IET Renewable Power Generation
This study discusses synthetic inertia from the perspective of a transmission system operator and compares it to fast frequency response based on frequency deviation. A clear distinction of the meanings between these concepts is discussed, the basis of which is a description of their characteristics. A contribution and the purpose is the clarification of these concepts in addition to share the perspectives of a transmission system operator. The frequency response of a power system based on the Nordic system is examined for future scenarios with large amounts of wind power. Conclusions are drawn regarding the benefit of synthetic inertia compared with fast frequency response based on frequency deviation.
13 July 2020 in IEEE Transactions on Power Systems
This paper develops a new method for voltage instability prediction using a recurrent neural network with long short-term memory. The method is aimed to be used as a supplementary warning system for system operators, capable of assessing whether the current state will cause voltage instability issues several minutes into the future. The proposed method use a long sequence-based network, where both real-time and historic data are used to enhance the classification accuracy. The network is trained and tested on the Nordic32 test system, where combinations of different operating conditions and contingency scenarios are generated using time-domain simulations. The method shows that almost all N-1 contingency test cases were predicted correctly, and N-1-1 contingency test cases were predicted with over 95 % accuracy only seconds after a disturbance. Further, the impact of sequence length is examined, showing that the proposed long sequenced-based method provides significantly better classification accuracy than both a feedforward neural network and a network using a shorter sequence.
29 June 2024 in Electric Power Systems Research
4 February 2021 in IEEE Transactions on Power Systems
This paper presents a comprehensive analysis of the impact that supplementary power control of an HVDC link has on the electromechanical dynamics of power systems. The presented work addresses an interesting phenomenon that may occur when an HVDC power controller is installed to support frequency stability. In specific cases, a high gain HVDC frequency controller could deteriorate system damping. The given analytical study is the first of its kind that addresses this issue by including both: (i) the important higher-order generator dynamics that affect small signal stability simultaneously with an HVDC control as well as (ii) the available local angle/frequency input signals of the controller. The methodological approach here analytically formulates the impact an HVDC control has on the single generator dynamics. Furthermore, the relationship between the damping/synchronizing coefficients and the HVDC gain is explicitly derived when a frequency proportional HVDC controller is installed. The derived expressions confirm that, indeed, there is an optimal HVDC gain with respect to the damping coefficient and a typically positive impact of the HVDC controller on the synchronizing component. Finally, the developed theoretical foundation is demonstrated by the tools of linear and nonlinear analysis in a one-machine system case study.
20 June 2018 in IEEE Transactions on Power Systems
This paper presents a new analytical approach for dc voltage control in dc grids. The control approach aims at improving the dc voltage droop control by generalized feedback which combines the local voltage signal available at the converter terminals with remote voltage signals at different locations in the dc system by means of communication. The main contribution is an analytical approach to derive the generalized feedback gain allowing to differentiating the system response for different converter outages. The goal of the system response is to share the power, in the event of disconnection of a converter, between the remaining converters according to a predetermined scheme. The local voltage feedback control is used for fast and reliable system response and, remote signals to achieve the goal. Analysis is also presented of the feasibility space the power shares which is a direct function of the grid layout. Simulation results show the validity of the proposed control scheme.
14 December 2021 in IEEE Transactions on Smart Grid
Modeling of distribution networks has received a renewed interest due to the appearance of dynamic phenomena arising from the increasing penetration levels of distributed generation. The conflicting implications of a model’s parsimony and flexibility, required model accuracy, available a priori information, and the purpose of a model, are inherent in system modeling. To tackle these issues, different models and identification methods have been proposed with the aim of representing the response of distributed generation to system events. The number of proposed models points to the fact that no single model can represent all possible dynamic behaviors of distribution networks. To facilitate, and even automate, model structure selection, this paper proposes a method that sequentially processes system events and classifies them as informative or noninformative for parameter identification. The method then uses informative events for parameter identification while the noninformative ones are used for optimal model structure selection and validation. Such selected and validated models can then be used in operation for dynamic security assessment of a transmission system. The performance of the proposed method is demonstrated in the case of equivalencing of a distribution network with photovoltaic and wind generation.