Emma Maggiolini

Emma Maggiolini

Auto-generated profile, based on publicly available information

Emma Maggiolini

Center for Translational Neurophysiology of Speech and Communication, Istituto Italiano di Tecnologia, Via Fossato di Mortara 17/19, 44121, Ferrara, Italy

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2017 in Scientific Reports
Verified
Journal Article
Open access
MVMaria Vomero
Maria Vomero
ECElisa Castagnola
Elisa Castagnola
FCFrancesca Ciarpella
Francesca Ciarpella
EMEmma Maggiolini
Emma Maggiolini
NGNoah Goshi
Noah Goshi
DRDavide Ricci
Davide Ricci
We report on the superior electrochemical properties,in-vivoperformance and long term stability under electrical stimulation of a new electrode material fabricated from lithographically patterned glassy carbon. For a direct comparison with conventional metal electrodes, similar ultra-flexible, micro-electrocorticography (μ-ECoG) arrays with platinum (Pt) or glassy carbon (GC) electrodes were manufactured. The GC microelectrodes have more than 70% wider electrochemical window and 70% higher CTC (charge transfer capacity) than Pt microelectrodes of similar geometry. Moreover, we demonstrate that the GC microelectrodes can withstand at least 5 million pulses at 0.45 mC/cm2charge density with less than 7.5% impedance change, while the Pt microelectrodes delaminated after 1 million pulses. Additionally, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) was selectively electrodeposited on both sets of devices to specifically reduce their impedances for smaller diameters (<60 μm). We observed that PEDOT-PSS adhered significantly better to GC than Pt, and allowed drastic reduction of electrode size while maintaining same amount of delivered current. The electrode arrays biocompatibility was demonstrated throughin-vitrocell viability experiments, while acutein vivocharacterization was performed in rats and showed that GC microelectrode arrays recorded somatosensory evoked potentials (SEP) with an almost twice SNR (signal-to-noise ratio) when compared to the Pt ones.

25 July 2014 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
ECElisa Castagnola
Elisa Castagnola
Luca MaioloLuca Maiolo
Luca Maiolo
EMEmma Maggiolini
Emma Maggiolini
AMAntonio Minotti
Antonio Minotti
MMMarco Marrani
Marco Marrani
DRDavide Ricci
Davide Ricci
Electrocorticography (ECoG) is becoming a common tool for clinical applications, such as preparing patients for epilepsy surgery or localizing tumor boundaries, as it successfully balances invasiveness and information quality. Clinical ECoG arrays use millimeter-scale electrodes and centimeter-scale pitch and cannot precisely map neural activity. Higher-resolution electrodes are of interest for both current clinical applications, providing access to more precise neural activity localization and novel applications, such as neural prosthetics, where current information density and spatial resolution is insufficient to suitably decode signals for a chronic brain-machine interface. Developing such electrodes is not trivial because their small contact area increases the electrode impedance, which seriously affects the signal-to-noise ratio, and adhering such an electrode to the brain surface becomes critical. The most straightforward approach requires increasing the array conformability with flexible substrates while improving the electrode performance using materials with superior electrochemical properties. In this paper, we propose an ultra-flexible and conformable polyimide-based micro-ECoG array of submillimeter recording sites electrochemically coated with high surface area conductive polymer-carbon nanotube composites to improve their brain-electrical coupling capabilities. We characterized our devices both electrochemically and by recording from rat somatosensory cortex in vivo. The performance of the coated and uncoated electrodes was directly compared by simultaneously recording the same neuronal activity during multiwhisker deflection stimulation. Finally, we assessed the effect of electrode size on the extraction of somatosensory evoked potentials and found that in contrast to the normal high-impedance microelectrodes, the recording capabilities of our low-impedance microelectrodes improved upon reducing their size from 0.2 to 0.1 mm.

1 October 2011 in Journal of Neural Engineering
Verified
Journal Article
Closed access
GBGytis Baranauskas
Gytis Baranauskas
EMEmma Maggiolini
Emma Maggiolini
ECElisa Castagnola
Elisa Castagnola
AAAlberto Ansaldo
Alberto Ansaldo
AMAlberto Mazzoni
Alberto Mazzoni
Luciano FadigaLuciano Fadiga
Luciano Fadiga
Extracellular metal microelectrodes are widely used to record single neuron activity in vivo. However, their signal-to-noise ratio (SNR) is often far from optimal due to their high impedance value. It has been recently reported that carbon nanotube (CNT) coatings may decrease microelectrode impedance, thus improving their performance. To tease out the different contributions to SNR of CNT-coated microelectrodes we carried out impedance and noise spectroscopy measurements of platinum/tungsten microelectrodes coated with a polypyrrole-CNT composite. Neuronal signals were recorded in vivo from rat cortex by employing tetrodes with two recording sites coated with polypyrrole-CNT and the remaining two left untreated. We found that polypyrrole-CNT coating significantly reduced the microelectrode impedance at all neuronal signal frequencies (from 1 to 10 000 Hz) and induced a significant improvement of the SNR, up to fourfold on average, in the 150-1500 Hz frequency range, largely corresponding to the multiunit frequency band. An equivalent circuit, previously proposed for porous conducting polymer coatings, reproduced the impedance spectra of our coated electrodes but could not explain the frequency dependence of SNR improvement following polypyrrole-CNT coating. This implies that neither the neural signal amplitude, as recorded by a CNT-coated metal microelectrode, nor noise can be fully described by the equivalent circuit model we used here and suggests that a more detailed approach may be needed to better understand the signal propagation at the electrode-solution interface. Finally, the presence of significant noise components that are neither thermal nor electronic makes it difficult to establish a direct relationship between the actual electrode noise and the impedance spectra.

16 April 2014 in Frontiers in Neuroengineering
Verified
Journal Article
Open access
PDF file
ECElisa Castagnola
Elisa Castagnola
AAAlberto Ansaldo
Alberto Ansaldo
EMEmma Maggiolini
Emma Maggiolini
Tamara IusTamara Ius
Tamara Ius
MSMiran Skrap
Miran Skrap
Luciano FadigaLuciano Fadiga
Luciano Fadiga
Finding the most appropriate technology for building electrodes to be used for long term implants in humans is a challenging issue. What are the most appropriate technologies? How could one achieve robustness, stability, compatibility, efficacy and versatility, for both recording and stimulation? There are no easy answers to these questions as even the most fundamental and apparently obvious factors to be taken into account, such as the necessary mechanical, electrical and biological properties and their interplay, are under debate. We present here our approach along three fundamental parallel pathways: we reduced electrode invasiveness and size without impairing signal-to-noise ratio, we increased electrode active surface area by depositing nanostructured materials and, we protected the brain from direct contact with the electrode without compromising performance. Altogether, these results converge towards high-resolution ECoG arrays that are soft and adaptable to cortical folds, and have been proven to provide high spatial and temporal resolution. This method provides a piece of work which, in our view, makes several steps ahead in bringing such novel devices into clinical settings, opening new avenues in diagnostics of brain diseases and neuroprosthetic applications.

22 February 2011 in ACS Nano
Verified
Journal Article
Closed access
AAAlberto Ansaldo
Alberto Ansaldo
ECElisa Castagnola
Elisa Castagnola
EMEmma Maggiolini
Emma Maggiolini
Luciano FadigaLuciano Fadiga
Luciano Fadiga
DRDavide Ricci
Davide Ricci

1 February 2012 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
GBGytis Baranauskas
Gytis Baranauskas
EMEmma Maggiolini
Emma Maggiolini
AVAlessandro Vato
Alessandro Vato
GAGiannicola Angotzi
Giannicola Angotzi
ABAndrea Bonfanti
Andrea Bonfanti
Luciano FadigaLuciano Fadiga
Luciano Fadiga
It has been noted that the power spectrum of intracortical local field potential (LFP) often scales as 1/f−2. It is thought that LFP mostly represents the spiking-related neuronal activity such as synaptic currents and spikes in the vicinity of the recording electrode, but no 1/f2 scaling is detected in the spike power. Although tissue filtering or modulation of spiking activity by UP and DOWN states could account for the observed LFP scaling, there is no consensus as to how it arises. We addressed this question by recording simultaneously LFP and single neurons (“single units”) from multiple sites in somatosensory cortex of anesthetized rats. Single-unit data revealed the presence of periods of high activity, presumably corresponding to the “UP” states when the neuronal membrane potential is depolarized, and periods of no activity, the putative “DOWN” states when the membrane potential is close to resting. As expected, the LFP power scaled as 1/f2 but no such scaling was found in the power spectrum of spiking activity. Our analysis showed that 1/f2 scaling in the LFP power spectrum was largely generated by the steplike transitions between UP and DOWN states. The shape of the LFP signal during these transitions, but not the transition timing, was crucial to obtain the observed scaling. These transitions were probably induced by synchronous changes in the membrane potential across neurons. We conclude that a 1/f2 scaling in the LFP power indicates the presence of steplike transitions in the LFP trace and says little about the statistical properties of the associated neuronal firing.