Andrew Edward Kilding

Andrew Edward Kilding

Auto-generated profile, based on publicly available information

Andrew Edward Kilding

Sports Performance Research Institute New Zealand, Auckland University of Technology, Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2015 in Sports Medicine - Open
Verified
Journal Article
Open access
PDF file
KBKyle R Barnes
Kyle R Barnes
AKAndrew E Kilding
Andrew E Kilding
Running economy (RE) is considered an important physiological measure for endurance athletes, especially distance runners. This review considers 1) how RE is defined and measured and 2) physiological and biomechanical factors that determine or influence RE. It is difficult to accurately ascertain what is good, average, and poor RE between athletes and studies due to variation in protocols, gas-analysis systems, and data averaging techniques. However, representative RE values for different caliber of male and female runners can be identified from existing literature with mostly clear delineations in oxygen uptake across a range of speeds in moderately and highly trained and elite runners. Despite being simple to measure and acceptably reliable, it is evident that RE is a complex, multifactorial concept that reflects the integrated composite of a variety of metabolic, cardiorespiratory, biomechanical and neuromuscular characteristics that are unique to the individual. Metabolic efficiency refers to the utilization of available energy to facilitate optimal performance, whereas cardiopulmonary efficiency refers to a reduced work output for the processes related to oxygen transport and utilization. Biomechanical and neuromuscular characteristics refer to the interaction between the neural and musculoskeletal systems and their ability to convert power output into translocation and therefore performance. Of the numerous metabolic, cardiopulmonary, biomechanical and neuromuscular characteristics contributing to RE, many of these are able to adapt through training or other interventions resulting in improved RE.

16 October 2009 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
AKAndrew E. Kilding
Andrew E. Kilding
SBSarah Brown
Sarah Brown
AMAlison K. McConnell
Alison K. McConnell

1 August 2009 in Sports Medicine
Verified
Journal Article
Closed access
PDF file
NSNicholas M. Stone
Nicholas M. Stone
AKAndrew E. Kilding
Andrew E. Kilding

25 October 2011 in Measurement in Physical Education and Exercise Science
Verified
Journal Article
Closed access
JHJono Hailstone
Jono Hailstone
AKAndrew E. Kilding
Andrew E. Kilding
The Zephyr™ BioHarness™ (Zephyr Technology, Auckland, New Zealand) is a wireless physiological monitoring system that has the ability to measure respiratory rate unobtrusively. However, the ability of the BioHarness™ to accurately and reproducibly determine respiratory rate across a range of intensities is currently unknown. The aim of this study was to determine the reliability and validity of the BioHarness™ to measure respiratory rate. Twelve physically active participants attended the laboratory on two separate occasions to perform an incremental treadmill test to volitional exhaustion. Respiratory rate (br.min−1) was measured continuously and simultaneously during both trials using both a Metamax 3b online gas-analysis system (Cortex, Leipzig, Germany) and the BioHarness™. The mean respiratory rate measured by the Metamax 3b and BioHarness™ did not differ statistically (p < .05) for most speeds, except for 70% of peak treadmill speed (p = .039). Mean absolute differences were small (2 to 3 br.min−1; typical error = 4.4%–8.7%). The typical errors for the test 1 versus the test 2 comparisons for respiratory rate ranged from 1.4 to 2.8 br.min−1 (typical error % = 4.3–7.3) for the BioHarness™. There were no significant differences between devices for the absolute respiratory rate, speed, and percent of respiratory rate maximum at the respiratory breakpoint (p > .05). The BioHarness™ is a valid and reliable device for determining respiratory rate and the respiratory breakpoint during exercise of varying intensity.

12 November 2020 in Nutrients
Verified
Journal Article
Open access
PDF file
JRJeffrey Rothschild
Jeffrey Rothschild
AKAndrew E. Kilding
Andrew E. Kilding
DPDaniel J. Plews
Daniel J. Plews
The primary variables influencing the adaptive response to a bout of endurance training are exercise duration and exercise intensity. However, altering the availability of nutrients before and during exercise can also impact the training response by modulating the exercise stimulus and/or the physiological and molecular responses to the exercise-induced perturbations. The purpose of this review is to highlight the current knowledge of the influence of pre-exercise nutrition ingestion on the metabolic, physiological, and performance responses to endurance training and suggest directions for future research. Acutely, carbohydrate ingestion reduces fat oxidation, but there is little evidence showing enhanced fat burning capacity following long-term fasted-state training. Performance is improved following pre-exercise carbohydrate ingestion for longer but not shorter duration exercise, while training-induced performance improvements following nutrition strategies that modulate carbohydrate availability vary based on the type of nutrition protocol used. Contrasting findings related to the influence of acute carbohydrate ingestion on mitochondrial signaling may be related to the amount of carbohydrate consumed and the intensity of exercise. This review can help to guide athletes, coaches, and nutritionists in personalizing pre-exercise nutrition strategies, and for designing research studies to further elucidate the role of nutrition in endurance training adaptations.

12 July 2022 in Sports Medicine
Verified
Journal Article
Open access
PDF file
JRJeffrey Rothschild
Jeffrey Rothschild
AKAndrew E. Kilding
Andrew E. Kilding
TSTom Stewart
Tom Stewart
DPDaniel J. Plews
Daniel J. Plews
Background: Multiple factors influence substrate oxidation during exercise including exercise duration and intensity, sex, and dietary intake before and during exercise. However, the relative influence and interaction between these factors is unclear. Objectives: Our aim was to investigate factors influencing the respiratory exchange ratio (RER) during continuous exercise and formulate multivariable regression models to determine which factors best explain RER during exercise, as well as their relative influence. Methods: Data were extracted from 434 studies reporting RER during continuous cycling exercise. General linear mixed-effect models were used to determine relationships between RER and factors purported to influence RER (e.g., exercise duration and intensity, muscle glycogen, dietary intake, age, and sex), and to examine which factors influenced RER, with standardized coefficients used to assess their relative influence. Results: The RER decreases with exercise duration, dietary fat intake, age, VO2max, and percentage of type I muscle fibers, and increases with dietary carbohydrate intake, exercise intensity, male sex, and carbohydrate intake before and during exercise. The modelling could explain up to 59% of the variation in RER, and a model using exclusively easily modified factors (exercise duration and intensity, and dietary intake before and during exercise) could only explain 36% of the variation in RER. Variables with the largest effect on RER were sex, dietary intake, and exercise duration. Among the diet-related factors, daily fat and carbohydrate intake have a larger influence than carbohydrate ingestion during exercise. Conclusion: Variability in RER during exercise cannot be fully accounted for by models incorporating a range of participant, diet, exercise, and physiological characteristics. To better understand what influences substrate oxidation during exercise further research is required on older subjects and females, and on other factors that could explain additional variability in RER.