A new hydrogen peroxide (H2O2) sensor is fabricated based on a multiwalled carbon nanotube-modified glassy carbon electrode (MWCNT-GCE) and reactive blue 19 (RB). The charge transfer coefficient, α, and the charge transfer rate constant, ks, of RB adsorbed on MWCNT-GCE were calculated and found to be 0.44 ± 0.01 Hz and 1.9 ± 0.05 Hz, respectively. The catalysis of the electroreduction of H2O2 by RB-MWCNT-GCE is described. The RB-MWCNT-GCE shows a dramatic increase in the peak current and a decrease in the overvoltage of H2O2 electroreduction in comparison with that seen at an RB modified GCE, MWCNT modified GCE, and activated GCE. The kinetic parameters such as α and the heterogeneous rate constant, k', for the reduction of H2O2 at RB-MWCNT-GCE surface were determined using cyclic voltammetry. The detection limit of 0.27μM and three linear calibration ranges were obtained for H2O2 determination at the RB-MWCNT-GCE surface using an amperometry method. In addition, using the newly developed sensor, H2O2 was determined in real samples with satisfactory results.
This study aims at designing a novel impedimetric aptasensor to determine carcinoembryonic antigen (CEA). The CEA aptasensor was developed by covalent immobilization of an amine-modified CEA aptamer on the surface of a glassy carbon electrode (GCE) which was modified by gold nanoparticles (AuNPs) incorporated in amino-functionalized MCM–41 (AMCM). After the aptamer was immobilized, CEA was incubated on the surface of an Ap-GA-AuNPs/AMCM-GCE. The change in the interfacial charge transfer resistance (Rct) of the redox marker served as an excellent signal for the quantitative determination of CEA. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to display the aptamer immobilization on the electrode surface. Through the EIS method, the linear range and the detection limit of CEA were found to be 1.0 × 10−3−100.0 ng mL−1 and 9.8 × 10−4 ng mL−1 respectively. Moreover, the proposed aptasensor was used to determine of CEA in patient and healthy human serum samples and the results indicated that this aptasensor has great potential for practical application which the strength point of this aptasensor.
This paper is a study of the fabrication, electrochemical characteristics, and electrocatalytic activity of 4-((2-hydroxyphenylimino)methyl)benzene-1,2-diol electrodeposited on a multi-walled carbon nanotube modified glassy carbon electrode (HPIMBD–MWCNT-GCE) as a hydrazine sensor. Cyclic voltammetric, chronoamperometric, and amperometric methods were used to probe the fabrication, and characterization of the modified electrode and its role as a sensor in the electrocatalytic determination of hydrazine. The cyclic voltammograms of HPIMBD–MWCNT-GCE show one pair of peaks with surface confined characteristics. The charge transfer coefficient, α, and the charge transfer rate constant, ks, between electrodeposited HPIMBD and MWCNT-GCE were calculated at various pHs. The results show that the modified electrode exhibited a catalytic activity toward the electrooxidation of hydrazine. The catalytic rate constant of the hydrazine oxidation at the modified electrode surface was determined using cyclic voltammograms recorded at various potential scan rates. Furthermore, amperometry exhibits two linear dynamic ranges of 4.0–32.9 μM and 32.9–750.4 μM and a detection limit of 1.1 μM for hydrazine determination. Finally, the activity of the modified electrode was studied for hydrazine determination in tap water and in auxiliary cooling water of power generation and satisfactory results were obtained.