14 September 2020 in IEEE Journal of Solid-State Circuits
This article presents a 320 x 240 indirect time-of-flight (iToF) CMOS image sensor (CIS) with on-chip motion artifact suppression and background light cancelling (BGLC). The proposed iToF CIS uses a backside-illuminated trident pinned photodiode (PPD) that assists charge transfer with a built-in lateral electric field for enhanced depth accuracy. To overcome the limitation of the conventional iToF CIS that exhibits motion artifact, we propose a pseudo-four-tap (P4-tap) demodulation method with alternate phase driving using a conventional two-tap pixel structure with a high fill factor of over 43%. In addition, by combining the advantages of both the P4-tap and conventional two-tap demodulation schemes, we propose hybrid depth imaging with reduced motion artifact for moving objects, while providing high-depth precision for the static background. For outdoor mobile applications of the iToF CIS, we integrated on-chip BGLC circuits to eliminate the BGL-induced depth error. A prototype chip is fabricated using a 90-nm backside illumination (BSI) CIS process. The BSI trident PPD enabled a low depth error of under 0.54% over the range of 0.75-4 m, with a modulation frequency of 100 MHz. Motion artifact was suppressed at 60 frames/s of hybrid depth imaging owing to the proposed P4-tap scheme. With the on-chip BGLC circuit, the experimental results demonstrate a 0.55% depth error at a 1-m distance, even under 120-klx BGL illumination.
8 July 2022 in IEEE Transactions on Circuits and Systems I: Regular Papers
We present a low-power indirect time-of-flight (iTOF) image sensor with fixed depth noise compensation and dual-mode imaging for depth dynamic range (DDR) enhancement. To reduce the power consumption from high-frequency pixel modulation, a TX driver with a single-sided clock chain is employed in the sensor. The inherent phase delay of the clock chain and the delay of the row bus are measured using row-parallel and column-parallel time-to-digital converters (TDCs) to compensate for the column and row fixed depth noise (FDN). To achieve a wide depth dynamic range (WDDR), the reconfigurable pixels and column circuits support dual-mode: short-range (SR) and long-range (LR) modes. A WDDR image is generated in a single frame through the mixed reconfiguration of the pixel array and interpolation. In addition, the temporal noise is suppressed without a significant time budget through a fast multiple sampling (FMS) scheme with 10b successive approximation register (SAR) analog-to-digital (ADCs). A prototype iTOF image sensor was fabricated using a 110 nm frontside illumination (FSI) CMOS image sensor (CIS) process and fully characterized. The sensor achieved a DDR of 4 m (0.7 to 4.7 m) with less than 1.7% nonlinearity and 0.9% depth noise. The FDN was suppressed to less than 2.1 cm at a low power consumption below 70 mW through the proposed compensation scheme using row and column TDCs. The temporal noise was only 0.48 mV $_{\mathbf {rms}}$ owing to the FMS.
31 January 2020 in Communications for Statistical Applications and Methods
Myung Soo Yoo, Donguk Kim. CSAM 2020;27:1-14. https://doi.org/10.29220/CSAM.2020.27.1.001
1 January 2012 in Korean Journal of Anesthesiology
The chemical reaction of carbon dioxide absorbent and sevoflurane is known to produce compound A. However, carbon dioxide absorbents are not controlled by the Food and Drug Administration, but are treated as industrial products in some nations. Moreover, carbon dioxide absorbents differ in their capacities to produce compound A, because their chemical compositions differ. In this study, we compared the renal safety between carbon dioxide absorbent products in patients under sevoflurane anesthesia. Eighty patients with no preexisting renal disease undergoing elective gynecologic surgery were randomly assigned to receive sevoflurane or isoflurane anesthesia with one of four carbon dioxide absorbent products (Sodasorblime®, Sodalyme®, Sodasorb®, Spherasorb®) at the same fresh gas flow of 2 L/min. The renal safety was evaluated by changes of blood urea nitrogen (BUN), creatinine and urine N-acetyl-b-glucoseaminidase (NAG)-creatinine ratio at 24 hours and 72 hours after surgery from preoperative level. There was no significant difference in the renal safety indicators between carbon dioxide absorbents during sevoflurane anesthesia (P > 0.05). However, the BUN and urine NAG-creatinine ratios at 72 hours after surgery were higher in isoflurane anesthesia in some carbon dioxide absorbent groups (P = 0.03 and 0.04, respectively). We could not find significant differences of renal safety indicators with carbon dioxide absorbents. Although the adverse effect of carbon dioxide absorbents on renal function was not proved, consideration should be given to their contol by the regulation on their efficacy and safety because carbon dioxide absorbents can produce compound A.