Crispin Kyela Mulaji

Crispin Kyela Mulaji

Auto-generated profile, based on publicly available information

Crispin Kyela Mulaji

University of Kinshasa (UNIKIN), Faculty of Science, Department of Chemistry, B.P. 190, Kinshasa XI, Democratic Republic of the Congo

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2016 in Frontiers in Microbiology
Verified
Journal Article
Open access
ALAmandine Laffite
Amandine Laffite
PKPitchouna I. Kilunga
Pitchouna I. Kilunga
JKJohn M. Kayembe
John M. Kayembe
NDNaresh Devarajan
Naresh Devarajan
CMCrispin K. Mulaji
Crispin K. Mulaji
JPJohn Pote
John Pote
Data concerning the occurrence of emerging biological contaminants such as antibiotic resistance genes (ARGs) and fecal indicator bacteria (FIB) in aquatic environments in Sub-Saharan African countries is limited. On the other hand, antibiotic resistance remains a worldwide problem which may pose serious potential risks to human and animal health. Consequently, there is a growing number of reports concerning the prevalence and dissemination of these contaminants into various environmental compartments. Sediments provide the opportunity to reconstruct the pollution history and evaluate impacts so this study investigates the abundance and distribution of toxic metals, FIB, and ARGs released from hospital effluent wastewaters and their presence in river sediments receiving systems. ARGs (blaTEM, blaCTX-M, blaSHV, and aadA), total bacterial load, and selected bacterial species FIB (E. coli, Enterococcus (ENT)) and Pseudomonas species (Psd) were quantified by targeting species specific genes using quantitative PCR (qPCR) in total DNA extracted from the sediments recovered from 4 hospital outlet pipes (HOP) and their river receiving systems in the City of Kinshasa in the Democratic Republic of the Congo. The results highlight the great concentration of toxic metals in HOP, reaching the values (in mg kg-1) of 47.9 (Cr), 213.6 (Cu), 1434.4 (Zn), 2.6 (Cd), 281.5 (Pb), and 13.6 (Hg). The results also highlight the highest (P˂0.05) values of 16S rRNA, FIB, and ARGs copy numbers in all sampling sites including upstream (control site), discharge point, and downstream of receiving rivers, indicating that the hospital effluent water is not an exclusive source of the biological contaminants entering the urban rivers. Significant correlation were observed between (i) all analyzed ARGs and total bacterial load (16S rRNA) 0.51 to 0.72 (p<0.001, n=65); (ii) ARGs (except blaTEM) and FIB and Psd 0.57 < r < 0.82 (p<0.001, n=65); and (iii) ARGs (except blaTEM) and toxic metals (Cd, Cr, Cu, and Zn) 0.44 to 0.72, (p<0.001, n=65). These findings demonstrate that several sources including hospital and urban wastewaters contribute to the spread of toxic metals and biological emerging contaminants in aquatic ecosystems.

1 September 2016 in Waste Management
Verified
Journal Article
Closed access
BMBienvenu K. Mavakala
Bienvenu K. Mavakala
SFSéverine Le Faucheur
Séverine Le Faucheur
CMCrispin K. Mulaji
Crispin K. Mulaji
ALAmandine Laffite
Amandine Laffite
NDNaresh Devarajan
Naresh Devarajan
JPJohn Pote
John Pote

24 February 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NDNaresh Devarajan
Naresh Devarajan
ALAmandine Laffite
Amandine Laffite
CMCrispin Kyela Mulaji
Crispin Kyela Mulaji
JOJean-Paul Otamonga
Jean-Paul Otamonga
PMPius Tshimankinda Mpiana
Pius Tshimankinda Mpiana
JPJohn Pote
John Pote
The occurrence of emerging biological contaminants including antibiotic resistance genes (ARGs) and Faecal Indicator Bacteria (FIB) is still little investigated in developing countries under tropical conditions. In this study, the total bacterial load, the abundance of FIB (E. coli and Enterococcus spp. (ENT)), Pseudomonas spp. and ARGs (blaTEM, blaCTX-M, blaSHV, blaNDM and aadA) were quantified using quantitative PCR in the total DNA extracted from the sediments recovered from hospital outlet pipes (HOP) and the Cauvery River Basin (CRB), Tiruchirappalli, Tamil Nadu, India. The abundance of bacterial marker genes were 120, 104 and 89 fold higher for the E. coli, Enterococcus spp. and Pseudomonas spp., respectively at HOP when compared with CRB. The ARGs aadA and blaTEM were most frequently detected in higher concentration than other ARGs at all the sampling sites. The ARGs blaSHV and blaNDM were identified in CRB sediments contaminated by hospital and urban wastewaters. The ARGs abundance strongly correlated (r ≥ 0.36, p < 0.05, n = 45) with total bacterial load and E. coli in the sediments, indicating a common origin and extant source of contamination. Tropical aquatic ecosystems receiving wastewaters can act as reservoir of ARGs, which could potentially be transferred to susceptible bacterial pathogens at these sites.

7 July 2016 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
PKPitchouna I. Kilunga
Pitchouna I. Kilunga
JKJohn M. Kayembe
John M. Kayembe
ALAmandine Laffite
Amandine Laffite
FTFlorian Thevenon
Florian Thevenon
NDNaresh Devarajan
Naresh Devarajan
JPJohn Pote
John Pote
Although the United Nations General Assembly recognized in 2010 the right to safe and clean drinking water and sanitation as a human right that is essential to the full enjoyment of life and all other human rights, the contamination of water supplies with faecal pathogens is still a major and unsolved problem in many parts of the world. In this study, faecal indicator bacteria (FIB), including Escherichia coli (E. coli) and Enterococcus (ENT), were quantified over the period of June/July 2014 and June/July 2015 to assess the quality of hospital effluents (n = 3: H1, H2 and H3) and of rivers receiving wastewaters from the city of Kinshasa, Democratic Republic of Congo. The water and sediment samples from the river-receiving systems were collected in, upstream and downstream of the hospital outlet pipe (HOP) discharge. The analysis of E. coli and ENT in water and sediment suspension was performed using the cultural membrane filter method. The FIB characterization was performed for general E. coli, Enterococcus faecalis(E. faecalis) and human-specific Bacteroides by PCR using specific primers. The results revealed very high FIB concentration in the hospital effluent waters, with E. coli reaching the values of 4.2 × 105, 16.1 × 105 and 5.9 × 105 CFU 100 mL−1, for the hospital effluents from H1, H2, and H3, respectively; and Enterococcus reaching the values of 2.3 × 104, 10.9 × 104 and 4.1 × 104 CFU 100 mL−1, respectively. Interestingly, the FIB levels in the water and sediment samples from river-receiving systems are spatially and temporally highly variable and present in some samples with higher values than the hospital effluents. The PCR assays for human-specific Bacteroides HF183/HF134 further indicate that more than 98% of bacteria were from human origin. The results of this research therefore confirm the hypothesis of our previous studies, indicating that in developing countries (e.g., Democratic Republic of Congo and South India), the hospital effluent waters can be a significant source of the deterioration of the bacteriological quality for urban rivers. The approach used in this investigation can be further used to decipher the pollution of water resources by human faecal contamination. The results of this research will help to better understand the microbiological pollution problems in river-receiving systems and will guide municipality decisions on improving the urban water quality.

27 January 2016 in Comptes Rendus. Chimie
Verified
Journal Article
Closed access
CMCrispin Mulaji
Crispin Mulaji
PDPascal Disa-Disa
Pascal Disa-Disa
IKIrène Kibal
Irène Kibal
MCMarc Culot
Marc Culot
This study is a part of the research methods for sustainable management of sandy soils of the province of Kinshasa (DRC).The intended aim is to characterize the soil sites with high agricultural activity in Kinshasa and to identify the main constraints to productivity. The diagnosis revealed that soils of three sites investigated studied are sandy and characterized by low retention capacity in the field (< 45 %) present an acid reaction (pH <5.5), have very low TOC contents (≤ 1 %), N tot (≤ 0.1 %), P ass (< 20 mg.kg −1 ), inexchangeable bases and are saturated to more than 60 % Al. Microbiological characteristics are weak in terms of microbial carbon, basal and induced respiration, and enzymatic activities. These characteristics are influenced by the organic matter and are the limitations on the productivity of these soils.

15 December 2014 in Revue Des Sciences de L'eau / Journal of Water Science
Verified
Journal Article
Closed access
PDF file
PDPascal Disa-Disa
Pascal Disa-Disa
MCMarc Culot
Marc Culot
JLJoseph Lobo
Joseph Lobo
IKIgnace Kalala
Ignace Kalala
CKChristophe Kawita
Christophe Kawita
CMCrispin Mulaji
Crispin Mulaji
La possibilité d’éliminer la turbidité et les coliformes, en utilisant un système de filtration lente sur sable à plusieurs étapes, a été étudiée à l’échelle du laboratoire. Le but de l’étude était de montrer que cette technologie constitue une solution de traitement efficace de l’eau en milieu rural et dans de petites agglomérations des pays en voie de développement. Dans cette étude, un système a été monté et testé. Ce système était constitué de deux filtres lents à sable en série, lesquels sont précédés de deux filtres à granulométrie grossière à flux ascendant. L’efficacité de cette technologie a été évaluée par la mesure de la turbidité et le dénombrement des coliformes totaux et thermotolérants. Les résultats obtenus ont montré : (i) d’excellents abattements de la turbidité malgré le niveau élevé de celle de l’eau brute (de 20 unités de turbidité néphélométrique (NTU) à plus de 100 NTU); (ii) une bonne élimination des coliformes, en fonction de la maturité biologique des filtres utilisés; (iii) de plus, il a été constaté que la turbidité de l’effluent à la sortie du second filtre lent à sable était largement en dessous de la norme de l’Organisation Mondiale de la Santé (OMS) concernant l’eau potable. Globalement, chaque étape individuelle du système de filtration à plusieurs étapes joue un rôle important dans le processus global de réduction de la turbidité, ainsi que du nombre de coliformes. Il a été remarqué que le filtre à granulométrie grossière, en plus de son rôle protecteur de filtre lent à sable contre les matières en suspension, constitue aussi une barrière importante de traitement dans la diminution du nombre de coliformes. L’addition d’un second filtre lent à sable en série a apporté une efficacité supplémentaire au processus de traitement, en ramenant la turbidité d’effluent proche de 1 NTU et en permettant d’obtenir des abattements additionnels de coliformes.