Ali Khodayari Bavil

Ali Khodayari Bavil

Auto-generated profile, based on publicly available information

Ali Khodayari Bavil

Department of Mechanical Engineering

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in The Analyst
Verified
Journal Article
Closed access
PDF file
ABAli Khodayari Bavil
Ali Khodayari Bavil
JKJungkyu (Jay) Kim
Jungkyu (Jay) Kim
A simple, reliable, and self-powered capillary flow-driven microfluidic platform is developed for conducting microparticle-labeled immunoassays. To obtain the washing forces and binding kinetics appropriate for microparticle-labeled immunoassays, both microchannel networks and sample access holes are designed and characterized to confirm the fluidic routes. To demonstrate two different types of immunoassays, serial and parallel capillary-driven microfluidic platforms were developed for mouse immunoglobulin G (IgG) and cardiac troponin I (cTnI) using detection antibody-conjugated microparticles, respectively. With the serial capillary-driven microfluidic platform, we successfully demonstrated IgG quantification using direct immunoassay and achieved a limit of detection (LOD) of 30 pM by using pre-immobilized mouse IgG. In the parallel capillary-driven microfluidic platform, a sandwich immunoassay for detecting cTnI was demonstrated and a clinically relevant LOD as low as 4.2 pM was achieved with minimal human intervention. In both assays, the association rate constants (Ka) were measured to estimate the overall assay time. According to these estimations, microparticle-labeled immunoassays could be conducted in a few minutes using the proposed capillary-driven microfluidic devices. By coupling with various magnetic sensors, these simple immunoassay platforms enable us to achieve a true sample-in-answer-out device that can screen for a variety of targets without relying on external power sources for fluidic manipulation.

10 March 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
ABAli Khodayari Bavil
Ali Khodayari Bavil
DSDrago Sticker
Drago Sticker
MRMario Rothbauer
Mario Rothbauer
PEPeter Ertl
Peter Ertl
JKJungkyu (Jay) Kim
Jungkyu (Jay) Kim
A microfluidic impedance biosensor incorporated with various microparticles is introduced for signal enhancement to realize a digital point-of-care diagnostic platform.

16 March 2017 in Mechanics & Industry
Verified
Journal Article
Closed access
PDF file
ABAli Khodayari Bavil
Ali Khodayari Bavil
SRSeyed Esmail Razavi
Seyed Esmail Razavi
The enhancement of heat transfer by the turbulator ribs in cooling channels causes increases of pressure drop. To achieve high thermal performance, a variety of techniques are employed. This study numerically investigates the heat transfer, fluid flow and thermal performance factor in the rib-roughened straight rectangular channel. The ribs have a circular shape and are mounted on the two opposite walls in a staggered arrangement. Four different rib attack angles of 90°, 60°, 45° and 30° to the main flow direction are treated. The results are obtained at entrance Reynolds number of range 25 000–50 000. Air is considered as convective fluid in steady state distribution. The three-dimensional flow is simulated with a two-layer k-ε turbulence model. The governing equations are solved by a control-volume based procedure using second-order upwind scheme. The computational results are compared with the experimental data under the same conditions. It is found that regarding heat transfer enhancement, circular ribs are in preference to block ones. In addition, the angled ribs could enhance the heat transfer significantly when compared to the ribs in 90° due to the generation of secondary flows. Concerning thermal performance factor, the optimum rib angle is also proposed for different Reynolds numbers.

13 August 2021 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
ABAli Khodayari Bavil
Ali Khodayari Bavil
VCVladimir Coltisor
Vladimir Coltisor
ZEZachary Estlack
Zachary Estlack
JKJungkyu (Jay) Kim
Jungkyu (Jay) Kim
A pulsatile microfluidic pump transports discrete volume to specific target locations. However, backflow in the pulsatile microfluidic pump often decreases the pumping efficiency and causes unwanted sample mixing due to unsteady boundaries. Employing the concept of a transistor, we developed a pneumatically controlled microfluidic rectifier (PCMR) that prevents backflow in the pulsatile flow regime. This PCMR was interconnected with a microfluidic pulsatile pumping system to characterize the functions of PCMR under continuous pumping sequences (CPS) and discrete pumping sequences (DPS) with various gate pressures on the PCMR. In the passive mode (zero gate pressure), 1.07% backflow for a DPS and 0.12% for a CPS were achieved. However, by adjusting the gate pressure on PCMR actively, we were able to achieve zero backflow for both pumping sequences at the cost of pumping efficiency. Interestingly, when the flow passes through the PCMR under the controlled gate-pressure, a fluidic oscillation was observed due to the force balance between the fluidic pressure and the gate-pressure. This microfluidic system successfully demonstrated half-rectification from various pulsatile flow profiles. By incorporating multiple three-microvalve systems in parallel with frequency modulation, a fully rectified flow pattern can be realized to enable steady laminar flow from pulsatile micropumps.