Saida Charre-Ibarra

Saida Charre-Ibarra

Auto-generated profile, based on publicly available information

Saida Charre-Ibarra

Universidad de Colima

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
VCVictor Cardenas
Victor Cardenas
AAAlejandro Aganza-Torres
Alejandro Aganza-Torres
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
SCSaida Charre
Saida Charre
Nowadays, the use of power converters to control active and reactive power in AC–AC grid-connected systems has increased. With respect to indirect AC–AC converters, the tendency is to enable the back-to-back (BTB) voltage source converter (VSC) as an active power filter (APF) to compensate current harmonics. Most of the reported works use the BTB-VSC as an auxiliary topology that, combined with other topologies, is capable of active power regulation, reactive power compensation and current harmonic filtering. With the analysis presented in this work, the framework of the dynamics associated with the control loops is established and it is demonstrated that BTB-VSC can perform the three tasks for which, in the reviewed literature, at least two different topologies are reported. The proposed analysis works to support the performance criteria of the BTB-VSC when it executes the three control actions simultaneously and the total current harmonic distortion is reduced from 27.21% to 6.16% with the selected control strategy.

5 January 2019 in XIKUA Boletín Científico de la Escuela Superior de Tlahuelilpan
Verified
Journal Article
Open access
PDF file
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
IRIsrael Rosales
Israel Rosales
SCSaida Charre
Saida Charre
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
MDMiguel Duran
Miguel Duran
DVDaniel Vélez-Díaz
Daniel Vélez-Díaz
Este artículo introduce el diseño mecánico y la construcción de un exoesqueleto, para su aplicación en el área de la medicina, específicamente para la rehabilitación y diagnóstico de extremidad inferior de pacientes niños. Además, se presenta los planos anatómicos del cuerpo humano y el exoesqueleto ortopédico, así como sus medidas antropométricas. En la co-simulación se muestra la estática y dinámica del exoesqueleto ortopédico, donde se describe la fuerza a la que es sometido para ver su máximo valor, así como las pruebas experimentales que se realizan al exoesqueleto montado sobre un niño.

18 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
Jose Antonio Juárez VelázquezJose Antonio Juárez Velázquez
Jose Antonio Juárez Velázquez
VCVictor Cardenas
Victor Cardenas
SCSaida Charre-Ibarra
Saida Charre-Ibarra
JRJuan Alejandro González Rivera
Juan Alejandro González Rivera
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
The growing adoption of renewable energy conversion systems and smart infrastructures has increased the demand for accurate monitoring solutions to ensure system performance and reliability, as well as seamless integration with cloud-based platforms. Voltage and current sensing are central to this task; however, sensor selection often involves a trade-off between cost and measurement precision. Rather than comparing technologies as equivalent options, this study investigates the practical impact of using low-cost versus high-precision sensors in electrical power generation monitoring. The evaluation includes representative low-cost sensors and high-precision alternatives based on instrumentation amplifiers and a closed-loop Hall-effect transducer. All sensors were characterized under controlled laboratory conditions and analyzed using statistical indicators, including MAE, RMSE, MAPE, and R2. Results show that high-precision sensors achieved R2 > 0.97 and MAPE < 4%, whereas low-cost sensors showed R2 as low as 0.73 and errors exceeding 10% under dynamic irradiance conditions. Low-cost sensors present deviations of 5–8% in RMS measurement, while high-precision sensors maintain error below 1%.

5 July 2020 in XIKUA Boletín Científico de la Escuela Superior de Tlahuelilpan
Verified
Journal Article
Open access
PDF file
DVDaniel Veléz-Díaz
Daniel Veléz-Díaz
APAimee Pozo-Méndez
Aimee Pozo-Méndez
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
SCSaida Charre-Ibarra
Saida Charre-Ibarra
El presente trabajo describe la importancia de la co-simulación en el diseño de un exoesqueleto y en el área de la medicina robótica. La metodología propuesta consta de dos procesos: el diseño y análisis mecánico; y el desarrollo del algoritmo de control para demostrar el buen funcionamiento del exoesqueleto. El análisis del mecanismo es creado a través de CAD en el software SolidWorks, que es empleado para diseños asistidos por computadora ya que permite evaluar la parte mecánica antes de ser construida. Para la validación del exoesqueleto, se implementa la simulación del caminado de una persona, esto es realizado con el software de Matlab empleando un algoritmo de control lineal. Lo anterior, permite analizar y crear rutinas de rehabilitación con la ayuda de un exoesqueleto co-simulado de la parte inferior del ser humano, que emula los movimientos de una marcha normal del humano y su control del movimiento, con la finalidad de lograr un movimiento natural del humano y ayudar en el tema de la discapacidad de pacientes con lesiones en la parte inferior del cuerpo.

11 November 2022 in Pädi Boletín Científico de Ciencias Básicas e Ingenierías del ICBI
Verified
Journal Article
Open access
PDF file
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
CLCesar Llamas-Woodward
Cesar Llamas-Woodward
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
SCSaida Charre-Ibarra
Saida Charre-Ibarra
AJAlejandro Jarillo-Silva
Alejandro Jarillo-Silva
MFMiguel Angel Duran Fonseca
Miguel Angel Duran Fonseca
Actualmente hay poca literatura e investigaciones relacionadas con el seguimiento de ojos (Eye Tracking) para la manipulación de robots o dispositivos mecatrónicos. Los artículos que se tienen hoy en día están enfocadas al estudio del ojo humano especialmente a la medicina, marketing y juego; sin embargo, son pocas dedicadas al control o manipulación de la tecnología (domótica, robots móviles: terrestres, aéreos o acuáticos, brazos robóticos, dispositivos mecatrónicos, entre otros). Por lo anterior, este artículo se centra en el diseño y construcción de un dispositivo mecatrónico para registrar el seguimiento ocular del ser humano con la finalidad de manipular un brazo robots de tres grados de libertad; y el desarrollo de una interfaz gráfica hombre-máquina amigable para visualizar el ojo humano y los comandos para la manipulación del robot.

5 January 2024 in XIKUA Boletín Científico de la Escuela Superior de Tlahuelilpan
Verified
Journal Article
Open access
PDF file
Janeth AlcaláJaneth Alcalá
Janeth Alcalá
LHLeonardo Romero Huerta
Leonardo Romero Huerta
JFJosé Daniel Tena Favela
José Daniel Tena Favela
SISaida Miriam Charre Ibarra
Saida Miriam Charre Ibarra
Jorge Gudiño LauJorge Gudiño Lau
Jorge Gudiño Lau
MFMiguel Angel Duran Fonseca
Miguel Angel Duran Fonseca
En este estudio se propone una interfaz gráfica para analizar el comportamiento de las lámparas más utilizadas en bajo voltaje y se desarrolla utilizando MATLAB® App Designer. La propuesta de esta herramienta se fundamenta como un recurso educativo didáctico para estudiar y comprender conceptos de calidad de la energía y los efectos de la conexión de luminarias a la red eléctrica. Los resultados presentados muestran el alcance de la interfaz desarrollada en su versión beta.