Dongli Jia

Dongli Jia

Auto-generated profile, based on publicly available information

Dongli Jia

China Electric Power Research Institute Company Ltd., Haidian, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in Energy Reports
Verified
Journal Article
Open access
Keyan LiuKeyan Liu
Keyan Liu
DJDongli Jia
Dongli Jia
YSYazhou Sun
Yazhou Sun
CWChenhao Wei
Chenhao Wei
GGGuangfei Geng
Guangfei Geng

27 July 2021 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
Keyan LiuKeyan Liu
Keyan Liu
DJDongli Jia
Dongli Jia
FZFengzhan Zhao
Fengzhan Zhao
QZQicheng Zhang
Qicheng Zhang
SHShuai Hao
Shuai Hao
SZShuai Zhang
Shuai Zhang
In order to improve the accuracy of theoretical energy loss calculation in low voltage distribution area (LV-area), this paper proposes a new prediction method based on variational mode decomposition (VMD) and particle swarm optimization (PSO) least squares support vector machine (LSSVM). Firstly, the main influencing factors of energy loss calculation in LV-area are determined by the grey correlation method, which reflects the data-driven characteristic of the method and ensures the objectivity of the prediction results and the generalization of the calculation model. Secondly, the trend component and fluctuation component are obtained by VMD of daily energy loss series in the LV-area. The variable set of main influencing factors of energy losses is used as the input variable of LSSVM, and the VMD result of the energy loss sequence is used as the output. The theoretical energy loss training and calculation model of LV-area is established. Compared with the traditional calculation model, this model has more accurate calculation accuracy by taking into account the frequency characteristics of energy losses in different frequency bands. PSO is used to optimize the parameters of LSSVM for the purpose of improving the accuracy of LSSVM. Finally, an example of 252 LV-area in a city in northern China is given to verify the validity of the proposed method. The results indicate that the proposed method generates more accurate results.

24 July 2025 in IEEE Access
Verified
Journal Article
Open access
DJDongli Jia
Dongli Jia
XYXiaoyu Yang
Xiaoyu Yang
KHKaiyuan He
Kaiyuan He
FDFeng Deng
Feng Deng
ZWZhentong Wang
Zhentong Wang
TLTianle Li
Tianle Li
The accuracy and reliability of single-ended fault location methods are often affected by boundary elements and transition resistances. This paper proposes a single-ended fault location method for DC transmission lines based on the initial traveling wave dominant frequency (ITWDF) attenuation characteristics. Firstly, the attenuation characteristics of the initial traveling wave frequency component are analyzed, and the attenuation law and distribution differences between the frequency component and fault distance are revealed. Secondly, to accurately extract and describe the trend of the initial traveling wave frequency component with the change of fault distance, the energy of the initial traveling wave is constructed, and the mathematical expression of the ITWDF related to the fault distance and unit length distortion coefficient is obtained. Theoretical analysis verifies that the ITWDF exhibits a monotonic attenuation mapping relationship with increasing fault distance. In addition, the attenuation characteristics of the ITWDF are not affected by fault impedance. Finally, a fault sample set containing the ITWDF and reference unit length distortion coefficients at different positions is constructed. The fault location is calculated using the ITWDF and the reference unit length distortion coefficient, with continuous wavelet transform and inverse distance weighting interpolation algorithms applied, respectively. Simulation results show that the proposed method can reliably locate faults under high-impedance conditions of up to 800Ω, and the absolute error is less than 200m. Moreover, the proposed method can be applied to DC lines with various boundary structures, improving the reliability of single-ended fault location.