1 February 2013 in Ophthalmology
1 May 2012 in Ophthalmology
6 March 2018 in Biomedical Materials
Corneal transplantation is an important surgical treatment for many common corneal diseases. However, a worldwide shortage of tissue from suitable corneal donors has meant that many people are not able to receive sight-restoring operations. In addition, rejection is a major cause of corneal transplant failure. Bioengineering corneal tissue has recently gained widespread attention. In order to facilitate corneal regeneration, a range of materials is currently being investigated. The ideal substrate requires sufficient tectonic durability, biocompatibility with cultured cellular elements, transparency, and perhaps biodegradability and clinical compliance. This review considers the anatomy and function of the native cornea as a precursor to evaluating a variety of biomaterials for corneal regeneration including key characteristics for optimal material form and function. The integration of appropriate cells with the most appropriate biomaterials is also discussed. Taken together, the information provided offers insight into the requirements for fabricating synthetic and semisynthetic corneas for in vitro modeling of tissue development and disease, pharmaceutical screening, and in vivo application for regenerative medicine.
1 November 2011 in Journal of Cataract & Refractive Surgery
We report intraoperative capsular block syndrome occuring during the first 50 femtosecond laser-assisted cataract surgeries performed in our facility. Two patients had uneventful combined laser fragmentation, capsulotomy, and corneal incision procedures. In both cases, following transfer to the operating room and manual removal of the laser-cut capsulotomy, posterior capsule rupture was noted during hydrodissection, resulting in posterior dislocation of the lens. Pars plana vitrectomy, removal of the crystalline lens, and sulcus implantation of an intraocular lens were performed in both patients with good visual outcomes. Femtosecond laser-assisted cataract surgery changes the intraoperative environment with the generation of intracapsular gas and laser-induced changes in the cortex. With awareness of the changed intraocular environment following laser lens fragmentation and capsulotomy and a modification of the surgical technique, no additional cases of intraoperative CBS have been seen in more than 600 laser-assisted cataract surgery procedures performed to date at our facility. No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
24 January 2005 in Clinical & Experimental Ophthalmology
17 September 2012 in Clinical & Experimental Ophthalmology